MK22-B-2 [MEDER]
Reed Sensors for SMD Mounting; 干簧传感器用于SMD贴装型号: | MK22-B-2 |
厂家: | MEDER ELECTRONIC |
描述: | Reed Sensors for SMD Mounting |
文件: | 总5页 (文件大小:504K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MEDER electronic
MK22 Series
Reed Sensors for
SMD Mounting
DESCRIPTION
MK22-Sensors are magnetically operated, over
moulded Reed proximity Switches for SMD
mounting.
Lead design 1: Flat, straight leads for PCB slot
mounting.
FEATURES
Lead design 2: Flat, bent SMD leads (15.6 mm
length)
Lead design 3: Flat, bent SMD leads (19.5 mm
length)
• Over moulded Reed switches for better mechani-
cal resistance
• Flat leads in three different designs
• Tape & Reel package
• Six operate sensitivities available
• No external power required for sensor operation
Magnet force and position magnet/sensor
determine Pull-In and Drop-Out point. The sensors
are supplied taped & reeled according to IEC 286/
part 3 suitable for auto-placement.
APPLICATIONS
• Electronic PCB`s where all components are
surface mounted
• No power-requirement sensor for low power
applications
• Telecommunication applications
• Automotive applications
PAD LAYOUT
All dimensions in mm [inch]
unspecified tolerances +/- 0.1 mm
Lead design 2
Lead design 4
Lead design 1
2.00
2.00
2.00
17.00
17.00
20.50
www.meder.com
273
MK22 Series
MEDER electronic
Reed Sensors for
SMD Mounting
DIMENSIONS
All dimensions in mm [inch] unspecified tolerances +/- 0.1 mm
Lead design 1
Lead design 2
Lead design 4
www.meder.com
274
MEDER electronic
MK22 Series
Reed Sensors for
SMD Mounting
ORDER INFORMATION
Part Number Example
Magnetic
Sensitivity
Series
Lead Design
MK22 - B - 4
MK 22 -
Options
X -
X
A, B, C
1, 2, 4
B is the magnetic sensitivity
4 is the lead design
MAGNETIC SENSITIVITY
Sensitivity
Class
Pull In
AT Range
B
C
10 - 15
15 - 20
TAPE & REEL
www.meder.com
275
MK22 Series
MEDER electronic
Reed Sensors for
SMD Mounting
SOLDERING INFORMATION
reflow soldering conditions according JEDEC norm J-STD-020C
40 s
260 oC
183 oC
125 oC
Ramp up:
max. 6K/s
Ramp down:
max. 8/Ks
120 s
120-180 s
www.meder.com
276
MEDER electronic
MK22 Series
Reed Sensors for
SMD Mounting
CONTACT DATA
All Data at 20° C
Contact Ratings
Contact Form →
Form A
Min. Typ. Max. Units
Conditions
Any DC combination of V & A not
to exceed their individual max.‘s
Switching Power
20*
W
Switching Voltage
Switching Current
Carry Current
DC or peak AC
DC or peak AC
DC or peak AC
200
1.0
V
A
1.25
150
A
Static Contact Resistance (initial) w/ 0.5 V & 10 mA
mΩ
Insulation Resistance
RH 45%
1012
320
Ω
Breakdown Voltage
Operate Time incl. Bounce
Release Time
Voltage applied for 60 sec. min.
Measured w/ 100 % overdrive
Measured w/ no coil suppression
at 10 kHz cross contact
VDC
ms
0.5
0.1
ms
Capacitance
0.2
pF
Contact Operation **
Pull-In Switch unmodified
Drop-Out Switch unmodified
Environmental Data
Shock Resistance
Test coil KMS-02
Test coil KMS-02
10
3.5
28
AT
AT
5.5
1/2 sinus wave duration 11 ms
From 10 - 2000 Hz
50
20
g
Vibration Resistance
Ambient Temperature
Stock Temperature
g
10°C/ minute max. allowable
10°C/ minute max. allowable
5 sec.
-40
-50
130
130
260
oC
oC
oC
Soldering Temperature
* The indicated electrical data are maximum values and can vary downwards when using a more
sensitive switch. Consult factory if more detail is required.
** These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section.
Consult factory if more detail is required.
www.meder.com
277
相关型号:
©2020 ICPDF网 联系我们和版权申明