WRA2405YMT-2W [MICRODC]

2W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC/DC CONVERTER; 2W ,宽电压输入,隔离稳压双输出DC / DC转换器
WRA2405YMT-2W
型号: WRA2405YMT-2W
厂家: MICRODC POWER TECHNOLOGY CO., LTD    MICRODC POWER TECHNOLOGY CO., LTD
描述:

2W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC/DC CONVERTER
2W ,宽电压输入,隔离稳压双输出DC / DC转换器

转换器 输出元件 输入元件
文件: 总3页 (文件大小:448K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
WRA-YMT-2W&WRB-YMT-2W Series  
2W, WIDE INPUT, ISOLATED & REGULATED SINGLE/DUAL OUTPUT DC/DC CONVERTER  
SELECTION GUIDE  
Input  
Output  
Efficiency  
(%,Typ.)  
Voltage  
(VDC)  
Current(MA)  
order code  
Voltage(VDC)  
Range  
Nominal  
Max*  
Max.  
Min.  
±5  
±12  
±15  
3.3  
5
±200  
±83  
±67  
500  
FEATURES  
Wide (2:1) input range  
WRA1205YMT-2W  
WRA1212YMT-2W  
WRA1215YMT-2W  
WRB1203YMT-1W6  
WRB1205YMT-2W  
WRB1209YMT-2W  
WRB1212YMT-2W  
WRB1215YMT-2W  
WRA2405YMT-2W  
WRA2412YMT-2W  
WRA2415YMT-2W  
WRB2403YMT-1W6  
WRB2405YMT-2W  
WRB2409YMT-2W  
WRB2412YMT-2W  
WRB2415YMT-2W  
12  
12  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
24  
24  
9-18  
9-18  
22  
22  
22  
22  
22  
22  
22  
22  
40  
40  
40  
40  
40  
40  
40  
40  
±20  
±8  
±7  
50  
74  
78  
78  
70  
74  
76  
78  
79  
74  
78  
78  
72  
76  
78  
80  
80  
9-18  
Operating temperature: -40°C ~ +85 °C  
1500VDC isolation  
9-18  
400  
9-18  
40  
No heat sink required  
9
222  
9-18  
22  
Internal SMD construction  
MTBF>1,000,000 hours  
Short circuit protection(Automatic recovery)  
Industry standard pinout  
RoHS Compliance  
12  
167  
9-18  
16  
15  
133  
9-18  
13  
±5  
±12  
±15  
3.3  
5
±200  
±83  
±67  
500  
18-36  
18-36  
18-36  
18-36  
18-36  
18-36  
18-36  
18-36  
±20  
±8  
±7  
50  
400  
40  
9
222  
22  
MODEL SELECTION  
WRB 24 12 Y MT -2W  
12  
167  
16  
15  
133  
13  
Product Series  
Output Voltage  
Input Voltage  
Wide (2:1) Input Range  
Mini package style Rated Power  
*Input voltage can't exceed this value, or will cause the permanent damage.  
COMMON SPECIFICATIONS  
Item  
Test conditions  
Min.  
Typ.  
Max.  
Units  
%
Storage humidity range  
Operating temperature  
95  
85  
-40  
-55  
DESCRIPTION  
125  
Storage temperature  
Temp. rise at full load  
The WRA_YMT-2W & WRB_YMT-2W Series are specially  
designed for applications where  
a wide range input  
15  
voltage power supplies are isolated from the input power  
supply in a distributed power supply system on a circuit  
board.  
1.5mm from case for 10 seconds  
300  
Lead temperature  
Short circuit protection  
Cooling  
These products apply to:  
Continuous, automatic recovery  
Free air convection  
1) Where the voltage of the input power supply is wide  
range ( voltage range 2:1 ) ;  
2) Where isolation is necessary between input and output  
(Isolation Voltage 1500VDC);  
Epoxy Resin (UL94-V0)  
Package material  
MTBF  
3) Where the regulation of the output voltage and the  
output ripple noise are demanded.  
1000  
K hours  
5.2  
g
Weight  
MICRODC reserves the copyright  
http://www.microdc.cn  
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646  
Page 1 of 3  
WRA-YMT-2W&WRB-YMT-2W Series  
TYPICAL CHARACTERISTICS  
ISOLATION SPECIFICATIONS  
Item  
Test Conditions  
Min.  
Typ.  
Max.  
Units  
Isolation voltage  
Tested for 1 minute and 1mA max.  
Test at 500VDC  
1500  
1000  
VDC  
MΩ  
pF  
Isolation resistance  
Isolation capacitance  
Input/Output, 100KHz/1V  
85  
*Supply voltage must be discontinued at the end of short circuit duration.  
OUTPUT SPECIFICATIONS  
Item  
Output power  
Test Conditions  
Min.  
Typ.  
Max.  
Units  
See above products program  
Refer to recommended circuit  
Refer to recommended circuit  
From 10% to 100% load  
0.2  
2
W
%
Positive voltage accuracy  
Negative voltage accuracy  
Load regulation  
±1  
±3  
±3  
±5  
%
±0.5  
±0.2  
±1*  
±0.5  
±0.03  
150  
%
Line regulation  
Input voltage from low to high  
Refer to recommended circuit  
20MHz Bandwidth  
%
Temperature Drift (Vout)  
Output ripple& noise**  
Switching frequency  
%/℃  
mVp-p  
KHz  
35  
100% load, nominal input voltage  
300  
*Dual output models unbalanced load: ±5%.  
**Test ripple and noise by Parallel cablemethod. See detailed operation instructions at Testing of Power Converter section,  
application notes.  
RECOMMENDED CIRCUIT  
APPLICATION NOTE  
Requirement On Output Load  
In order to ensure the product operate efficiently and reliably, in addition to a max load (namely full  
load), a minimum load is specified for this kind of DC/DC converter. Make sure the specified range of  
input voltage is not exceeded, the minimum output load no less than 10% load. If the actual load is less  
than the specified minimum load, the output ripple may increase sharply while its efficiency and  
reliability will reduce greatly. If the actual output power is very small, please add an appropriate resistor  
as extra loading, or contact our company for other lower output power products.  
Recommended Circuit  
All the WRA_YMT-2W  
& WRB_YMT-2W Series have been tested according to the following  
recommended testing circuit before leaving factory. This series should be tested under load. (See Figure  
1).  
If you want to further decrease the input/output ripple, you can increase capacitance properly or  
choose capacitors with low ESR. However, the capacitance of the output filter capacitor must be proper.  
If the capacitance is too big, a startup problem might arise. For every channel of output, provided the  
safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1).  
General: Cin:  
12V  
100µF  
24V&48V  
10µF-47µF  
Cout: 10µF/100mA  
Input Current  
When it is used in unregulated power supply, be sure that the fluctuating range of the power supply  
and the rippled voltage do not exceed the module standard. Input current of power supply should afford  
the flash startup current of this kind of DC/DC module. (Figure 2)  
Output External Capacitor Table (Table 1)  
Single  
Cout  
Dual Vout  
Cout  
Vout  
(VDC)  
(μF)  
(VDC)  
(μF)  
General: Ip 1..4*Iin-max  
3.3  
5
2200  
1000  
680  
±5  
±9  
±12  
±15  
-
680  
470  
330  
220  
-
No parallel connection or plug and play  
9
12  
15  
470  
330  
http://www.microdc.cn  
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646  
Page 2 of 3  
WRA-YMT-2W&WRB-YMT-2W Series  
OUTLINE DIMENSIONS & PIN CONNECTIONS  
MECHANICAL DIMENSIONS  
RECOMMENDED FOOTPRINT(TOP VIEW)  
DUAL/SINGLE OUTPUT  
TUBE OUTLINE DIMENSIONS  
Note:  
Unit:mm[ inch]  
Pin section tolerances:±0.10mm[±0.004inch]  
General tolerances:±0.25mm[±0.010inch]  
FOOTPRINT DETAILS  
Pin  
Single  
Dual  
1
GND  
NC  
GND  
NC  
7
Note:  
8
NC  
0V  
Unit :mm[inch]  
9
+Vo  
0V  
+Vo  
-Vo  
Vin  
General tolerances: ±0.50mm[±0.020inch]  
L=530mm[20.866inch] Tube Quantity: 21pcs  
10  
16  
Vin  
L=220mm[8.661inch]  
Tube Quantity: 8pcs  
NC: No connection  
Note:  
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.  
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.  
3. Capacitor MAX load tested at input voltage range and full load.  
4. All specifications measured at Ta=25, humidity<75%, nominal input voltage and rated output load unless otherwise specified.  
5. In this datasheet, all the test methods of indications are based on corporate standards.  
6. Only typical models listed, other models may be different, please contact our technical person for more details.  
RoHS COMPLIANT INFORMATION  
This series is compatible with RoHS soldering systems with a peak wave solder temperature  
of 300°C for 10 seconds.  
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin  
with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this  
series are backward compatible with Sn/Pb soldering systems.  
Microdc Professional Power Module,Inc.  
Tel:0086-20-86000646 E-mail:tech@microdc.cn  
Website:http://www.microdc.cn  
REACH COMPLIANT INFORMATION  
This series has proven that this product does not contain harmful chemicals, it also has  
harmful chemical substances through the registration, inspection and approval.  
http://www.microdc.cn  
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646  
Page 3 of 3  

相关型号:

WRA2405YMT-3W

3W, WIDE INPUT , ISOLA TED & REGULATED SINGLE/DUAL OUTPUTDC/DC CONVERTER
MICRODC

WRA2405YQD-20W

20W,WIDEINPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUTDC-DCCONVERTER
MICRODC

WRA2405YQD-40W

30W~40W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER
MICRODC

WRA2405YS-1W

WIDE INPUT,ISOLATED & REGULATED Dual Output SIP DC/DC Converter
MICRODC

WRA2405YS-2W

WIDE INPUT,ISOLATED & REGULATED Dual Output SIP DC/DC Converter
MICRODC

WRA2405YS-3W

3W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER
MICRODC

WRA2405YT-2W

2W,WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLEOUTPUTDC/DCCONVERTER
MICRODC

WRA2405ZD-1W5

1.5W, WIDE INPUT, ISOLATED®ULATED DUAL OUTPUT DC-DC CONVERTER
MICRODC

WRA2405ZD-3W

3W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER
MICRODC

WRA2405ZD-4W

4W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER
MICRODC

WRA2405ZD-5W

5W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER
MICRODC

WRA2405ZD-6W

6W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER
MICRODC