WRA2412ZMD-10W [MICRODC]
10W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER; 10W ,宽电压输入,隔离稳压双输出DC- DC转换器型号: | WRA2412ZMD-10W |
厂家: | MICRODC POWER TECHNOLOGY CO., LTD |
描述: | 10W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER |
文件: | 总3页 (文件大小:1353K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WRA-ZMD-10W&WRB-ZMD -10W Series
10W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER
FEATURES
◆Wide (4:1) Input Range
◆Short Circuit Protection(automatic recovery)
◆1500VDC Isolation
SELECTION GUIDE
Input
Output
Current(mA)
Efficiency
(%,Typ)
Voltage(VDC)
Voltage
(VDC)
Order code
◆Operating Temperature: -40℃~﹢85℃
◆No heat sink required
Nominal
Range
9-36
Max*
Max.
Min.
WRA2405ZMD-10W
±5
±1000
±100
24
40
84
◆No external component required
◆Internal SMD required
WRA2412ZMD-10W
WRA2415ZMD-10W
WRB2405ZMD-10W
WRB2412ZMD-10W
WRB2415ZMD-10W
WRA4812ZMD-10W
WRA4815ZMD-10W
WRB4812ZMD-10W
WRB4815ZMD-10W
9-36
9-36
±12
±15
5
±416
±333
2000
833
±42
±33
200
83
24
24
24
24
24
48
48
48
48
40
40
40
40
40
80
80
80
80
81
83
79
81
81
85
83
85
83
◆Metal shielding package
9-36
◆MTBF>1000Khours
9-36
12
MODEL SELECTION
⑦
9-36
15
666
67
①
②
③
④
⑤
⑥
WRB 24 05 Z M D -10W
18-72
18-72
18-72
18-72
±12
±15
12
±416
±333
833
±42
±33
83
①Product Series
③Output Voltage
⑤Metal Shield
⑦Rated Power
②Input Voltage
④Wide (4:1) Input Range
⑥DIP Package Style
15
666
67
*Input voltage can’t exceed this value,or will cause the permanent damage.
APPLICATIONS
The WRA_ZMD-10W&WRB_ZMD-10W Series
are specially designed for applications where a
wide range input voltage power supplies are
isolated from the input power supply in a
distributed power supply system on a circuit
board.
COMMON SPECIFICATIONS
Parameter
Storage humidity
Operating temperature
Storage temperature
Temp. rise at full load
Lead temperature
Cooling
Conditions
Min.
Typ. Max. Units
These products apply to:
1 )Where the voltage of the input power
supply is wide range (Voltage range≤4:1);
2 )Where isolation is necessary between
input and output (Isolation voltage≤1500VDC);
3)Where the regulation of the Output voltage
and the output ripple noise are demanded.
95
85
%
℃
℃
℃
℃
-40
-55
125
40
1.5mm from case for 10 seconds
300
Free Air Convection
Short circuit protection
Continuous, Automatic recovery
Aluminum Alloy
Case material
Isolation voltage
Isolation resistance
Isolation Capacitance
MTBF
MICRODC RESERVES THE COPYRIGHT
Tested for1 minute and 1mA max
Test at 500VDC
1500
VDC
1000
MΩ
pF
Input/output
1000
23.5
K hours
g
1000
Weight
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
page 1/3
WRA-ZMD-10W&WRB-ZMD -10W Series
TYPICAL CHARACTERISTICS
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Units
Temperature Derating Graph
Output power
See below products program
1.0
10
W
Positive voltage accuracy
Negative voltage accuracy
Load regulation
Refer to recommended circuit
Refer to recommended circuit
Form 10% to 100% load
Input voltage from low to high
Refer to recommended circuit
20MHz Bandwidth
±1
±3
±3
±5
%
%
±0.5
±0.2
±1*
%
Line regulation
±0.5
±0.03
50
%
Temperature drift (Vout)
Ripple**
%/°C
mVp-p
mVp-p
KHz
20
75
Noise**
20MHz Bandwidth
150
Switching frequency
100% load, input voltage range
300
RECOMMENDED CIRCUIT
Output Graph
*
Dual output models unbalanced load: ±5%.
** Test ripple and noise by “parallel cable” method. See detailed operation instructions at
Testing of Power Converter section, application notes.
Case material
APPLICATION NOTE
Requirement on output load
In order to ensure the product operate efficiently and reliably,in addition to a
max load(namely full load), a minimum load is specified for this kind of
DC/DC converter.Make sure the specified range of input voltage is not
exceeded,the minimum output load no less than 10% load.If the actual load
is less than the specified minimum load, the output ripple may increase
sharply while its efficiency and reliability will reduce greatly.If the actual
output power is very small,please add an appropriate resistor as extra
loading,or contact our company for other lower output power products.
Recommended Circuit
All the WRA_ZMD-10W&WRB_ZMD-10W Series have been tested
according to the following recommended testing circuit before leaving
factory.This series should be tested under load(see Figure 1).
If you want to further decrease the input/output ripple,you can increase
capacitance properly or choose capacitors with low ESR.However,the
capacitance of the output filter capacitor must be proper.If the capacitance
is too big,a startup problem might arise.For every channel of output,provided
the safe and reliable operation is ensured,the greatest capacitance of its
filter capacitor sees (Table 1).General:
Cin: 10μF-47μF
Cout: 10μF/100mA
CTRL Terminal
When open or high impedance,the converter work well; When this pin is
‘high’; the converter shutdown; It should be note that the input current (Ic)
should between 5-10mA, exceeding the maximum 20mA will cause
permanence damage to the converter.
The value of R Can be derived as follows :
Output External Capacitor Table(Table 1)
Input current
Single Vout
Cout
(μF)
680
Dual Vout Cout
While using unstable power source,please ensure the output voltage and
ripple voltage do not exceed indexes of the converter.The preceding power
source must be able to provide for converter sufficient starting current
Ip(Figure 2).
(VDC)
(VDC)
±5
(μF)
680
5
General:Ip≤1.6*Iin-max
12
15
470
±12
±15
330
330
220
No parallel connection or plug and play
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
page 1/3
WRA-ZMD-10W&WRB-ZMD -10W Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
RECOMMENDED FOOTPRINT
MECHANICAL DIMENSIONS
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
RECOMMENDED FOOTPRINT
Top view,grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
FOOTPRINT DETAILS
Pin
1
Single
GND
Vin
Dual
GND
Vin
TUBE OUTLINE DIMENSIONS
2
3
+Vo
NC
+Vo
0V
4
5
0V
-Vo
NC:No connection
When the environment temperature is higher than 71℃,
the product output power should be less then 60% of
the rated power.
No parallel connection or plug and play.
Note:
Unit :mm[inch]
General tolerances:±0.50mm[±0.020inch]
L=230mm[9.055inch] Tube Quantity: 7pcs
Use dual output simultaneously,forbid pening output
pin (0V) to use as single output.
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. Only typical models listed, other models may be different, please contact our technical person for more details.
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
page 1/3
相关型号:
WRA2412ZT-1W5
1.5W,WIDE INPUT ISOLATED®ULATED SINGLE/DUAL OUTPUT DC/DC CONVERTER MINIATURE SMD PACKAGE
MICRODC
©2020 ICPDF网 联系我们和版权申明