WRA4805ZD-6W [MICRODC]
6W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER; 6W ,宽电压输入,隔离稳压双输出DC- DC转换器型号: | WRA4805ZD-6W |
厂家: | MICRODC POWER TECHNOLOGY CO., LTD |
描述: | 6W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER |
文件: | 总3页 (文件大小:1655K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WRA-ZD-6W&WRB-ZD -6W Series
6W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER
SELECTION GUIDE
Input
Output
Current(mA)
Efficiency
(%.Typ.)
FEATURES
◆Wide (4:1) Input Range
Voltage
(VDC)
Order code
Voltage(VDC)
Range
Nominal
24
Max*
40
Max.
Min.
◆Short Circuit Protection(automatic recovery)
◆1500VDC Isolation
WRA2405ZD-6W
9-36
±5
±60
76
±600
WRA2412ZD-6W
WRA2415ZD-6W
WRB2403ZD-6W
WRB2405ZD-6W
WRB2412ZD-6W
WRB2415ZD-6W
WRA4805ZD-6W
WRA4812ZD-6W
WRA4815ZD-6W
WRB4803ZD-6W
WRB4805ZD-6W
WRB4812ZD-6W
WRB4815ZD-6W
24
24
24
24
24
24
48
48
48
48
48
48
48
9-36
9-36
40
40
40
40
40
40
80
80
80
80
80
80
80
±12
±15
3.3
5
±25
±20
150
120
50
81
83
74
76
81
81
85
83
85
74
78
80
80
±250
±200
1500
1200
500
◆Operating Temperature: -40℃~﹢85℃
◆Five sided metal shielding
◆No external component required
◆Internal SMD construction
◆RoHS Compliance
9-36
9-36
9-36
12
9-36
15
40
400
18-72
18-72
18-72
18-72
18-72
18-72
18-72
±5
±12
±15
3.3
5
±60
±25
±20
150
120
50
±600
±250
±200
1500
1200
500
◆MTBF>1000Khours
MODEL SELECTION
⑥
①
②
③
④
⑤
WRB 24 12 Z D -6W
①Product Series ②Input Voltage
③Output Voltage ④Wide (4:1) Input Range
⑤DIP Package Style ⑥Rated Power
12
15
40
400
*Input voltage can’t exceed this value,or will cause the permanent damage.
APPLICATIONS
The WRA_ZD-6W&WRB_ZD-6W Series are
specially designed for applications where a wide
range input voltage power supplies are isolated
from the input power supply in a distributed
power supply system on a circuit board.These
products apply to:
COMMON SPECIFICATIONS
Parameter
Conditions
Min. Typ. Max. Units
1) Where the voltage of the input power
supply is wide range
(Voltage range≤4:1);
2) Where isolation is necessary between
input and output
Storage humidity
Operating temperature
Storage temperature
Temp. rise at full load
Lead temperature
Cooling
95
85
%
-40
-55
℃
℃
℃
℃
125
(Isolation voltage≤1500VDC);
40
3) Where the regulation of the Output
voltage and the output ripple noise are
demanded.
1.5mm from case for 10 seconds
300
Free Air Convection
Short circuit protection
Case material
Continuous,automatic recovery
Steel,nickel plated, plastic
Tested for1 minute and 1mA max
Test at 500VDC
Isolation voltage
Isolation resistance
Isolation Capacitance
MTBF
1500
1000
VDC
MΩ
MICRODC RESERVES THE COPYRIGHT
1000
17
pF
1000
K hours
g
Weight
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 3
WRA-ZD-6W&WRB-ZD -6W Series
TEMPERATURE CHARACTERISTICS
TYPICAL CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
6
Units
Temperature Derating Graph
Output power
See below products program
0.6
W
%
Positive voltage accuracy
Negative voltage accuracy
Load regulation
Refer to recommended circuit
Refer to recommended circuit
Form 10% to 100% load
Input voltage from low to high
Refer to recommended circuit
20MHz Bandwidth
±1
±3
±3
±5
%
±0.5
±0.2
±0.02
20
±2*
±0.5
%
Line regulation
%
Temperature drift (Vout)
Ripple**
%/℃
mVp-p
mVp-p
KHz
50
Noise**
20MHz Bandwidth
50
100
Switching frequency
100% load, input voltage range
300
*
Dual output models unbalanced load: ±5%.
RECOMMENDED CIRCUIT
** Test ripple and noise by “parallel cable” method. See detailed operation instructions at
Testing of Power Converter section, application notes.
Output Graph
Case material
APPLICATION NOTE
Requirement on output load
In order to ensure the product operate efficiently and reliably,in addition to a
max load(namely full load), a minimum load is specified for this kind of
DC/DC converter.Make sure the specified range of input voltage is not
exceeded,the minimum output load no less than 10% load.If the actual load
is less than the specified minimum load, the output ripple may increase
sharply while its efficiency and reliability will reduce greatly.If the actual
output power is very small,please add an appropriate resistor as extra
loading,or contact our company for other lower output power products.
Recommended Circuit
All the WRA_ZD-6W&WRB_ZD-6W Series have been tested according to the
following recommended testing circuit before leaving factory.This series
should be tested under load(see Figure 1).
If you want to further decrease the input/output ripple,you can increase
capacitance properly or choose capacitors with low ESR. However, the
capacitance should not be too high, or may cause start-up problem.
General:
Cin: 24V&48V 10μF-47μF
Cout: 10μF/100mA
Input current
While using unstable power source,please ensure the output voltage and
ripple voltage do not exceed indexes of the converter.The preceding power
source must be able to provide for converter sufficient starting current
Ip(Figure 2).
Output External Capacitor Table(Table 1)
General:Ip≤1.6*Iin-max
Single Vout
Cout
(μF)
2200
1000
470
Dual Vout Cout
(VDC)
3.3
5
(VDC)
±5
(μF)
680
330
220
--
No parallel connection or plug and play
±12
±15
--
12
15
330
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 3
WRA-ZD-6W&WRB-ZD -6W Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
RECOMMENDED FOOTPRINT
Top view grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
FOOTPRINT DETAILS
TUBE OUTLINE DIMENSIONS
Pin
2、3
9
Single
GND
NC
Dual
GND
0V
11
NC
-Vo
+Vo
0V
14
+Vo
0V
16
22、23
Vin
Vin
NC:No connection
When the environment temperature is higher than 71℃, the
product output power should be less then 60% of the rated
power.
Note:
Unit :mm[inch]
No parallel connection or plug and play.
Use dual output simultaneously,forbid pening output pin (0V)
to use as single output.
General tolerances:±0.50mm[±0.020inch]
L=530mm[20.866inch] Tube Quantity: 15pcs
L=220mm[8.661inch] Tube Quantity: 6pcs
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise
specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. Only typical models listed, other models may be different, please contact our technical person for more details.
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 3 of 3
相关型号: