WRB4812YMD-15W [MICRODC]
Isolated 15W Single Output DC/DC Converter; 隔离15W单输出DC / DC转换器型号: | WRB4812YMD-15W |
厂家: | MICRODC POWER TECHNOLOGY CO., LTD |
描述: | Isolated 15W Single Output DC/DC Converter |
文件: | 总4页 (文件大小:810K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WRB-YMD-15W Series
Isolated 15W Single Output DC/DC Converter
SELECTION GUIDE
Nominal
Input
Voltage
Output
Voltag
Output
Current Limit
A(MIN.) A(MAX.)
Efficiency
%
MTTF2
kHrs
Input
Current
order code
Voltage
V
V
A
WRB2403YMD-15W
WRB2405YMD-15W
WRB2412YMD-15W
WRB2415YMD-15W
WRB4803YMD-15W
WRB4805YMD-15W
WRB4812YMD-15W
WRB4815YMD-15W
2403-Y2X11K515W
2405-Y2X11K515W
2412-Y2X11K515W
2412-Y2X11K516W
4803-Y2X11K515W
4805-Y2X11K515W
4812-Y2X11K515W
4815-Y2X11K516W
24
24
24
24
48
48
48
48
3.3
5
4.4
3
7.5
5
11
7.5
3.7
3
81
84
86
87
83
85
88
89
335
286
286
281
295
301
302
296
FEATURES
◆RoHS compliant
12
15
3.3
5
1.3
1
2.5
2
4.4
3
7.5
5
11
◆High efficiency to 89%
◆Power density up to 2.4W/cm3
◆UL 94V-0 package material
◆Industry standard pinout
◆Non latching current limit
◆Constant 350kHz frequency
◆1.5kV input to output isolation
◆Versatile control options
7.5
3.7
3
12
15
1.3
1
2.5
2
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
18
Typ.
24
Max.
36
Units
Voltage range
Continuous operation, 24V input types
Continuous operation, 48V input types
V
36
48
72
◆Continuous rating to 30W at 40℃ without
OUTPUT CHARACTERISTICS
Heatsink
Parameter
Conditions
Min.
Typ.
Max.
Units
Voltage set point error
50% load
0.5
◆Operation to zero load
Case temperature -40oC to 110oC
Load 0% - 100%
%
◆Protected against load faults
◆Internal over temperature protection
◆Uses no electrolytic capacitors
Overall voltage error
2.5
Input specified range
Temperature coefficient
of output voltage (slope
ppmoC
250
Deviation of output
voltage
MODEL SELECTION
WRB 24 03 Y MD -15W
①
②
③
④
⑤
⑥
Temperature MIN-MAX
Operating voltage range, 50% load
0% - 100% rated load
rms
Line regulation
Load Regulation
Ripple
0.5
70
1
%
%
①Product Series
③Output Voltage
⑤Metal Shield
⑦Rated Power
②Input Voltage
④Wide (2:1) Input Range
⑥DIP Package Style
0.1
0.5
mV
DESCRIPTION
ISOLATION CHARACTERISTICS
The WRB-YMD-15W series of DC/DC converters
combines ease of application with versatility. The pin
pattern is based on the popular industry standard, but two
additional pins may optionally be fitted to provide a variety
of features not commonly found on units of this type. High
efficiency enables full rating to be achieved in a small
package without heats inking, and a high surge capability
will provide for start-up and transient loads, whilst being
thermally protected against sustained overload. Overload
protection of the “constant current” type ensures start-up
into complex load conditions. The copper case achieves
efficient heat transfer and screening. The product range
has been recognized by Underwriters Laboratory (UL) to
UL 1950 for operational insulation, file number E179522
applies.
Parameter
Isolation test
Resistance
Conditions
Flash tested for 1 second
VISO = 500VDC
Min.
1500
1
Typ.
Max.
Units
VDC
GΩ
ABSOLUTE MAXIMUM RATINGS
Input voltage, 24V input types
Input voltage, 48V input types
Output voltage
-0.5V to 40V
-0.5V to 80V
-0.3V to regulated voltage
-1V to +30V
Output trim control
Synchronisation/shutdown control
±15V relative to input return
1. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
2. Absolute maximum value for 30 seconds. Prolonged operation may damage the product.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
MICRODC reserves the copyright
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 4
WRB-YMD-15W Series
CONTROL CHARACTERISTICS
Parameter
Conditions
MIN.
TYP.
MAX.
Units
%
Voltage trimming range
At rated load, trim control at either output
Not operating
±10
Remote switch input (voltage relative to
input negative)1
-15
9
0
1.5
11
V
Operating, open circuit voltage
Time from application of valid input
voltage to output being in specification
Specified drive signal
10
Start Delay
25
50
ms
Synchronisation
320
330
440
395
KHz
KHz
Switching frequency
350
1. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
2. Absolute maximum value for 30 seconds. Prolonged operation may damage the product.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
MIN.
TYP.
MAX.
Units
Case temperature
Full load
-40
110
125
85
ºC
Storage
Absolute Max. internal temperature
Non condensing 85ºC
-40
Relative humidity
Thermal protection
%
Operates at case temperature
110
ºC
THERMAL CHARACTERISTICS
Max. permissable loads for a given ambient temperature for any WRB-15W model.
Temperature (ºC)
Power (W)
Temperature (ºC)
Power (W)
40
50
53
60
15
15
70
80
85
90
11.7
9.8
8.8
7.8
15
13.7
Max. power rating with case temperature maintained by external means (e.g. forced air cooling).
Case Temperature
Part Number
Units
100ºC
19
105ºC
16
110ºC
12
WRB2403YMD-15W
WRB2405YMD-15W
WRB2412YMD-15W
WRB2415YMD-15W
WRB4803YMD-15W
WRB4805YMD-15W
WRB4812YMD-15W
WRB4815YMD-15W
22
19
15
W
25
22
19
26
24
21
20
17
13
23
20
16
W
28
26
23
30
28
25
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 4
WRB-YMD-15W Series
THERMAL PERFORMANCE
24V Input
48V Input
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the
same thing, a test voltage,applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that
isolation.
MICRODC Power Solutions WR-YMD-15W series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1500
VDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The WR-YMD-15W series has been recognized by Underwriters Laboratory, both input and output should normally be maintained within SELV limits
i.e. less than 42.4V peak, or 60VDC.
The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation
system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the
circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier
between these circuits and any user-accessible circuitry according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater
degree depending on materials,construction and environment. While manufactured parts can withstand several times the stated test voltage, the
isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical
degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise
against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specifi ed test voltage.
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 3 of 4
WRB-YMD-15W Series
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
Pin
1
Function
-VIN
2
+VIN
3*
4
SS
+VOUT
TRIM
-VOUT
5*
6
* Optional pins
The copper case is internally connected to the output (-VOUT) pin. Care is needed in the design of this circuit board on which the converter is mounted. Top side tracks must
not contact the edge of the case or the ferrite core, visible on the underside of the unit. The case size may be (LXW)50.08mmX 25.4mm.
Please note that from 2010 onwards you may receive either a blue or a black case finish.
RECOMMENDED FOOTPRINT DETAILS
All dimensions in inches ±0.01 (mm ±0.25mm)
* Optional control pins
RoHS COMPLIANT INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature
of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin
with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this
series are backward compatible with Sn/Pb soldering systems.
Microdc Professional Power Module,Inc.
REACH COMPLIANT INFORMATION
Tel:0086-20-86000646 E-mail:tech@microdc.cn
This series has proven that this product does not contain harmful chemicals, it also has
harmful chemical substances through the registration, inspection and approval.
Website:http://www.microdc.cn
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 4 of 4
相关型号:
WRB4812YMD-20W
WIDE INPUT,ISOLATED & REGULATED Single Output DC/DC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRB4812YMD-3W
3W, WIDE INPUT, ISOLATED & REGULATED SINGLE OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRB4812YMD-3W
DUAL/SINGLE OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
WRB4812YMD-5W
WIDE INPUT,ISOLATED & REGULATED Single Output DC/DC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRB4812YMD-6W
Wide Input,Isolated& Regulated Single Output DC/DC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRB4812YMD-6W
DUAL/SINGLE OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
WRB4812YMT-3W
3W, WIDE INPUT , ISOLA TED & REGULATED SINGLE/DUAL OUTPUTDC/DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRB4812YQD-20W
20W,WIDEINPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUTDC-DCCONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRB4812YQD-40W
30W~40W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRB4812YS-1W
WIDE INPUT,ISOLATED & REGULATED Single Output SIP DC/DC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRB4812YS-2W
WIDE INPUT,ISOLATED & REGULATED Single Output SIP DC/DC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRB4812YS-3W
3W, WIDE INPUT, ISOLATED & REGULATED SINGLE OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
©2020 ICPDF网 联系我们和版权申明