WRD481515YD-3W [MICRODC]
3W, WIDE INPUT ISOLATED & REGULATED TWIN OUTPUT DIP DC-DC CONVERTER; 3W ,宽电压输入隔离稳压双输出DIP封装DC- DC转换器型号: | WRD481515YD-3W |
厂家: | MICRODC POWER TECHNOLOGY CO., LTD |
描述: | 3W, WIDE INPUT ISOLATED & REGULATED TWIN OUTPUT DIP DC-DC CONVERTER |
文件: | 总3页 (文件大小:648K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WRD-YD-3W Series
3W, WIDE INPUT ISOLATED & REGULATED TWIN OUTPUT DIP DC-DC CONVERTER
PRODUCT PROGRAM
Input
Output
Current(MA)
Part
Efficiency
(%,Typ)
No-load
Current
(mA,Typ)
Voltage
(VDC)
Voltage(VDC)
Number
Nominal
Range
Max*
Max
Min.
WRD050505YD-3W
WRD051212YD-3W
WRD051515YD-3W
WRD120505YD-3W
WRD120909YD-3W
WRD121212YD-3W
WRD121515YD-3W
WRD122424YD-3W
WRD240505YD-3W
WRD240512YD-3W
WRD241212YD-3W
WRD241515YD-3W
WRD242405YD-3W
WRD242424YD-3W
WRD480505YD-3W
WRD480512YD-3W
WRD480909YD-3W
WRD481212YD-3W
WRD481515YD-3W
WRD482424YD-3W
4.5-9.0
4.5-9.0
4.5-9.0
12
4.5-9.0
4.5-9.0
4.5-9.0
9.0-18
9.0-18
9.0-18
9.0-18
9.0-18
18-36
18-36
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
36-72
36-72
11
11
11
22
22
22
22
22
40
40
40
40
40
40
80
80
80
80
80
80
40
40
40
20
20
20
20
20
10
10
10
10
10
10
5
5/5
12/12
15/15
5/5
300/300
125/125
100/100
300/300
166/166
125/125
100/100
62/62
30/30
12/12
10/10
30/30
16/16
12/12
10/10
6/6
68
71
72
76
78
80
81
82
76
77
80
79
81
81
76
78
78
80
81
82
FEATURES
◆2:1 wide input voltage range
12
9/9
◆Twin output
12
12/12
15/15
24/24
5/5
12
◆Operating temperature: -40℃ to + 85℃
◆UL94-V0 package
12
24
300/300
300/125
125/125
100/100
62/300
30/30
30/12
12/12
10/10
6/30
24
5/12
12/12
15/15
24/05
24/24
5/5
◆No external component required
◆Industry standard pinout
◆Short circuit protection(automatic recovery)
◆ Five-sided metal shielding(WRD-YD)
◆ MTBF>1,000,000 hours
◆ No heat sink required
24
24
24
24
62/62
6/6
48
300/300
400/83
30/30
40/8
48
5
5/12
9/9
48
5
166/166
125/125
100/100
62/62
16/16
12/12
10/10
6/6
48
5
12/12
15/15
24/24
48
5
48
5
◆ RoHS Compliance
*Input voltage can't exceed this value, or will cause the permanent damage.
MODEL SELECTION
①
②
③
④
⑤
⑥
⑦
WRD 05 05 05 Y D -3W
①Product Series
②Input Voltage
③1st Output Voltage
⑤Wide (2:1) Input Range
⑦Rated Power
④2nd Output Voltage
⑥Package Style
APPLICATIONS
The WRD_YD-3W series are specially designed for
applications where
a wide range input voltage power
supplies are isolated from the input power supply in a
distributed power supply system on a circuit board.
These products apply to:
COMMON SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
Units
1)Where the voltage of the input power supply is wide
range (voltage range≤2:1);
Storage humidity
Operating temperature
Storage Temperature
Temp. rise at full load
Lead temperature
Cooling
95
85
%
2)Where isolation is necessary between input and
output (Isolation Voltage≤1500VDC);
-40
-55
125
℃
3)Where isolation is necessary between Vout1 and
Vout2 (Isolation Voltage≤1000VDC);
15
1.5mm from case for 10 seconds
300
4)Where the regulation of the output voltage and the
output ripple noise are demanded.
Free Air Convection
Plastic (UL94-V0)
Case Material
Short circuit protection
MTBF
Continuous, Automatic Recovery
1000
K hours
g
Weight
15
MICRODC reserves the copyright
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 3
WRD-YD-3W Series
TYPICAL CHARACTERISTICS
ISOLATION SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
Units
Isolation voltage
Tested for 1 minute and 1mA max
Test at 500VDC
1500
1000
VDC
MΩ
pF
Isolation resistance
Isolation capacitance
Input/Output, 100KHz/1V
100
*Supply voltage must be discontinued at the end of short circuit duration.
OUTPUT SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
Units
Output power
Main output voltage accuracy
Vice-output voltage accuracy
Load regulation
Refer to product program
Refer to recommended circuit
Refer to recommended circuit
From 10% to 100% load
Input voltage from low to high
Refer to recommended circuit
20MHz Bandwidth
0.3
3
±3
W
±1
±3
±5
%
±0.5
±0.2
±1*
±0.5
±0.03
50
Line regulation
Temperature drift (Vout)
Ripple**
%/℃
mVp-p
KHz
20
75
RECOMMENDED CIRCUIT
Noise**
20MHz Bandwidth
150
Switching frequency
100% load, input voltage range
300
*Dual output models unbalanced load: ±5%.
**Test ripple and noise by “parallel cable”method. See detailed operation instructions at Testing of Power
Converter section, application notes.
APPLICATION NOTE
1) Requirement On Output Load
In order to ensure the product operate efficiently and reliably, in addition to a max load (namely
full load), a minimum load is specified for this kind of DC/DC converter. Make sure the specified range of
input voltage is not exceeded, the minimum output load no less than 10% load. If the actual load is
less than the specified minimum load, the output ripple may increase sharply while its efficiency and
reliability will reduce greatly. If the actual output power is very small, please add an appropriate
resistor as extra loading, or contact our company for other lower output power products.
2) Recommended Circuit
All the WRD-YD-3W Series have been tested according to the following recommended testing circuit before
leaving factory. This series should be tested under load (see Figure 1).
If you want to further decrease the input/output ripple, you can increase capacitance properly or
choose capacitors with low ESR. However, the capacitance should not be too high, or may cause
start-up problem. If you want to use the products in high EMI, please choose our metal packaged
products (WRD_YD-3W). For every channel of output, provided the safe and reliable operation is ensured, the greatest
capacitance of its filter capacitor sees
(Table 1). General:
Cin: 5V,12V
24V&48V 22µF/10µF
Cout: 10µF/100mA
100µF
EXTERNAL CAPACITOR TABLE (TABLE 1)
Output External Capacitor Table (Table 1)
Vout(VDC)
Cout(uF)
680
3) Input Current
While using unstable power source, please ensure the output voltage and ripple voltage do not exceed indexes of the
converter. The preceding power source must be able to provide for converter sufficient starting current Ip (Figure 2).
General: Ip≤1.4*Iin-max
5
9
470
12
15
24
330
4) No parallel connection or plug and play
220
100
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 3
WRD-YD-3W Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT(TOP VIEW)
TUBE OUTLINE DIMENSIONS
RoHS COMPLIANT INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature
of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin
with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this
series are backward compatible with Sn/Pb soldering systems.
Microdc Professional Power Module,Inc.
Tel:0086-20-86000646 E-mail:tech@microdc.cn
Website:http://www.microdc.cn
REACH COMPLIANT INFORMATION
This series has proven that this product does not contain harmful chemicals, it also has
harmful chemical substances through the registration, inspection and approval.
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 3 of 3
相关型号:
WRD481515YKD-5W
5W, WIDE INPUT ISOLATED & REGULATED TWIN OUTPUT DIP24 DC-DC CONVERTER 5W,宽输入隔离双输出隔离电压1500VDC和稳压双输出DIP24封装 DC-DC变换器Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRD481515YKD-6W
6W, WIDE INPUT ISOLATED & REGULATED TWIN OUTPUT DIP24 DC-DC CONVERTER 6W,宽输入隔离双输出隔离电压1500VDC和稳压双输出DIP24封装 DC-DC变换器Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRD481515YS-1W
1W&2W,WIDE INPUT,ISOLATED®ULATED Twin Output DCâDC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRD481515YS-1W *
1W,WIDE INPUT,ISOLATED&UNREGULATED Twin Output DC∕DC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRD481515YS-2W
1W&2W,WIDE INPUT,ISOLATED®ULATED Twin Output DCâDC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRD481515YS-2W *
2W,WIDE INPUT,ISOLATED&UNREGULATED Twin Output DC∕DC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRD482424MP-3W
TWIN OUTPUT DIP DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
WRD482424YD-3W
3W, WIDE INPUT ISOLATED & REGULATED TWIN OUTPUT DIP DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRD482424YKD-5W
5W, WIDE INPUT ISOLATED & REGULATED TWIN OUTPUT DIP24 DC-DC CONVERTER 5W,宽输入隔离双输出隔离电压1500VDC和稳压双输出DIP24封装 DC-DC变换器Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRD482424YKD-6W
6W, WIDE INPUT ISOLATED & REGULATED TWIN OUTPUT DIP24 DC-DC CONVERTER 6W,宽输入隔离双输出隔离电压1500VDC和稳压双输出DIP24封装 DC-DC变换器Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRE-YD-3W
3W,WIDEINPUT, ISOLATED®ULATEDDUAL/SINGLEOUTPUTDC-DCCONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRE-YD-4W
4W,WIDEINPUT, ISOLATED®ULATEDDUAL/SINGLEOUTPUTDC-DCCONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
©2020 ICPDF网 联系我们和版权申明