RL107F [MIC]
FAST RECOVERY RECTIFIER; 快速恢复整流型号: | RL107F |
厂家: | MIC GROUP RECTIFIERS |
描述: | FAST RECOVERY RECTIFIER |
文件: | 总2页 (文件大小:47K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FAST RECOVERY RECTIFIER
VOLTAGE RANGE
50 to 1000 Volts
1.0 Ampere
RL101F THRU RL107F
CURRENT
FEATURES
A-405
·
·
·
·
·
Low coat construction
Fast switching for high efficiency.
Low reverse leakage
High forward surge current capability
High temperature soldering guaranteed:
260℃/10 secods/.375”(9.5mm)lead length at 5 lbs(2.3kg) tension
1.0(25.4)
MIN.
.205(5.2)
.166(4.2)
MECHANICAL DATA
.107(2.7)
.080(2.0)
DIA.
·
·
·
·
·
·
Case: Transfer molded plastic
Epoxy: UL94V-O rate flame retardant
Polarity: Color band denotes cathode end
Lead: Plated axial lead, solderable per MIL-STD-202E method 208C
Mounting position: Any
1.0(25.4)
MIN.
.025(0.6)
.021(0.5)
DIA.
Weight: 0.00081 ounce, 0.23 grams
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
·
·
·
Ratings at 25OC ambient temperature unless otherwise specified
Single Phase, half wave, 60Hz, resistive or inductive load
For capacitive load derate current by 20%
RL
SYMBOLS
RL
102F
RL
103F
RL
104F
RL
105F
RL
106F
RL
107F
UNITS
101F
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
VRRM
VRMS
VDC
50
35
50
100
70
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
Volts
Volts
Volts
Maximum DC Blocking Voltage
100
1000
Maximum Average Forward Rectified Current
0.375”(9.5mm) lead length at TA= 75℃
I(AV)
1.0
Amps
Peak Forward Surge Current
8.3mS single half sine wave superimposed on
rated load (JEDEC method)
IFSM
VF
IR
30
Amps
Volts
µA
Maximum Instantaneous Forward Voltage @ 1.0A
1.3
5.0
100
250
15
TA = 25℃
TA = 100℃
Maximum DC Reverse Current at Rated
DC Blocking Voltage
Maximum Reverse Recovery Tine (Note 3) TL=25℃
trr
CJ
150
500
ns
Typical Junction Capacitance (Note 1)
pF
Typical Thermal Resistance (Note 2)
RθJA
50
℃/W
Operating Junction Temperature Range
Storage Temperature Range
Notes:
℃
℃
TJ
(-55 to +150)
(-55 to +150)
TSTG
1.Measured at 1.0MHz and Applied Reverse Voltage of 4.0Volits.
2. Thermal Resistance from junction to Ambient at .375”(9.5mm)lead length, P.C.board mounted.
3.Reverse Recovery Test Conditions:If=0.5A,Ir=1.0A,Irr=0.25A
E-mail: sales@cnmic.com
Web Site: www.cnmic.com
FAST RECOVERY RECTIFIER
VOLTAGE RANGE
50 to 1000 Volts
1.0 Ampere
RL101F THRU RL107F
CURRENT
RATING AND CHRACTERISTIC CURVES RL101F Thur RL107F
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
FIG.2-MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
1.2
1.0
0.8
0.6
30
25
20
8.3ms Single Half Sine-Wave
T
(JEDEC Method) =T
j
jmax
0.4
0.2
Single Phase
10
Half Wave 60Hz
Resistive or
Inductive Load
0
0
100
175
20
100
150
125
1
2
5
50
10
0
25
50
75
8
NUMBER OF CYCLES AT 60 Hz
AMBIENT TEMPERATURE, (° C)
FIG.3-TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
100
10
1
10
1.0
0.1
Tj =100° C
0.1
T =25° C
j
Pulse Width=300us
1% Duty Cycle
T =25° C
j
0.01
1.6
1.8
2.0
0.6
0.8
1.0
1.2
1.4
140
120
60
100
80
40
20
0
INSTANTANEOUS FORWARD VOLTAGE,(V)
PERCENT OF RATED PEAK
REVERSE VOLTAGE,(%)
FIG.5-TYPICAL JUNCTION CAPACITANCE
100
10
TJ=25° C F=1MHz
10
0.1
1.0
10.0
100
4.0
REVERSE VOLTAGE,(VOLTS)
E-mail: sales@cnmic.com
Web Site: www.cnmic.com
相关型号:
RL107FG
FAST RECOVERY GLASS PASSIVATED RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.0 Ampere
RECTRON
©2020 ICPDF网 联系我们和版权申明