ZARC-26-12 [MINI]
High Power Signal Tap;型号: | ZARC-26-12 |
厂家: | MINI-CIRCUITS |
描述: | High Power Signal Tap |
文件: | 总2页 (文件大小:266K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
26 dB DC Pass
High Power Signal Tap
ZARC-26-12+
50Ω
100W
20 to 100 MHz
The Big Deal
• High Power Handling, 100 W
• Excellent Mainline Loss, 0.1 dB typ.
• Excellent VSWR, 1.1:1 typ.
CASE STYLE: AW1564
Product Overview
The ZARC-26-12+ high power signal tap is ideal for monitoring up to 100 W RF signals in SW and VHF applications. Overall
dimensions are 3.00” x 2.81” x 2.03” high. The rugged aluminum alloy case features stainless steel SMA connectors and an
anodized aluminum heat sink, enclosing a welded module for reliable, long-term performance.
Feature
Advantages
0.1 dB typ. mainline loss
Extremely low internal power dissipation, reducing mainline loss and internal temperature for high reliability
0.2 dB coupling ꢀatness
Provides highly accurate sampling of signal power
VSWR 1.1:1 typ
Excellent 50Ω impedance matching minimizes interference with signal integrity
DC Pass up to 3A
100 W input maximum
Suitable for applications using remote antenna control or other remote motorized requirements
High power capacity, combined with excellent insertion loss and VSWR, supports operation in transmitters
and base stations for amateur radio, PMR, FM, broadcast TV, aviation, and military applications
Notes
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.
B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions.
C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp
®
Mini-Circuits
www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com
Page 1 of 2
26 dB DC Pass
High Power Signal Tap
ZARC-26-12+
50Ω
100W
20 to 100 MHz
Features
Maximum Ratings
Operating Temperature
-40°C to 85°C
-55°C to 100°C
100W max.
3A
• excellent mainline loss, 0.1 dB typ.
• very ꢀat coupling 0.2 dB typ.
• excellent VSWR, 1.1 typ.
CASE STYLE: AW1564
Connectors Model
Storage Temperature
Power Input
SMA
ZARC-26-12-S+
DC Current (IN-OUT)
Permanent damage may occur if any of these limits are exceeded.
Applications
• instrumentation
• amateur radio
+RoHS Compliant
The +Suffix identifies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualifications
Coaxial Connections
INPUT
1
2
3
OUTPUT
COUPLED
Electrical Specifications at 25°C
Parameter
Condition (MHz)
Min.
Typ.
Max.
Unit
20
—
—
—
100
0.10
0.15
0.20
MHz
Frequency Range
20
60
0.03
0.06
0.10
26.3
26.2
26.3
26.4
0.05
0.10
36
Outline Drawing
dB
dB
Mainline Loss (above theoretical 0.011 dB)
Coupling* (IN-CPL, OUT-CPL)
100
20 - 100
20
25.9
25.8
25.6
—
26.6
26.8
27.2
0.20
0.25
—
60
100
20 - 60
60 - 100
20
dB
dB
Coupling Flatness(±)
Return Loss (Input)
—
25
60
20
27
—
100
20
18
23
—
25
36
—
60
20
27
—
dB
Return Loss (Output)
100
20
18
23
—
inch
Outline Dimensions ( mm
)
25
45
—
A
B
C
D
E
F
1.525
38.74
G
.125
3.18
60
25
34
—
dB
W
Return Loss (Coupling)
3.00
2.06
2.03
.10 2.500
100
20 - 100
20
30
—
76.20 52.32 51.56
2.54 63.50
—
—
100
Input Power
H
.50
J
.50
K
.50
L
2.00
M
1.00
N
wt
* Coupling can be used for both forward and reversed direction.
2.00 grams
50.80 230
12.70 12.70 12.70 50.80 25.40
Typical Performance Data
Frequency
(MHz)
Mainline Loss
(dB)
Coupling
(dB)
Return Loss
(dB)
Out
Electrical Schematic
In-Out
In
Cpl
In-Cpl
Out-Cpl
20.00
30.00
40.00
50.00
60.00
70.00
80.00
90.00
95.00
100.00
0.03
0.03
0.04
0.04
0.05
0.05
0.06
0.06
0.07
0.07
26.23
26.21
26.23
26.24
26.26
26.27
26.28
26.28
26.28
26.28
26.23
26.22
26.24
26.27
26.28
26.31
26.33
26.35
26.36
26.37
43.05
40.25
37.78
36.20
34.69
33.39
32.20
31.24
30.73
30.29
42.30
39.82
37.57
35.75
34.33
33.15
31.90
30.91
30.51
30.05
47.14
41.93
38.81
36.68
34.95
33.47
32.19
31.06
30.54
30.04
ZARC-26-12+
COUPLING
ZARC-26-12+
RETURN LOSS
ZARC-26-12+
MAINLINE LOSS
at RF level of -10 dBm
at RF level of -10 dBm
at RF level of -10 dBm
0.10
0.08
0.06
0.04
0.02
0.00
60
50
40
30
20
10
60
50
40
30
20
10
0
IN
OUT
CPL
IN-CPL
OUT-CPL
20
40
60
80
100
20
40
60
80
100
20
40
60
FREQUENCY (MHz)
80
100
FREQUENCY (MHz)
FREQUENCY (MHz)
Notes
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.
B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions.
REV. A
M151107
C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp
ED-14165/1
ZARC-26-12+
CH/CP/AM
151007
Page 2 of 2
®
Mini-Circuits
www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com
相关型号:
©2020 ICPDF网 联系我们和版权申明