ZARC-26-12 [MINI]

High Power Signal Tap;
ZARC-26-12
型号: ZARC-26-12
厂家: MINI-CIRCUITS    MINI-CIRCUITS
描述:

High Power Signal Tap

文件: 总2页 (文件大小:266K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
26 dB DC Pass  
High Power Signal Tap  
ZARC-26-12+  
50Ω  
100W  
20 to 100 MHz  
The Big Deal  
• High Power Handling, 100 W  
• Excellent Mainline Loss, 0.1 dB typ.  
• Excellent VSWR, 1.1:1 typ.  
CASE STYLE: AW1564  
Product Overview  
The ZARC-26-12+ high power signal tap is ideal for monitoring up to 100 W RF signals in SW and VHF applications. Overall  
dimensions are 3.00” x 2.81” x 2.03” high. The rugged aluminum alloy case features stainless steel SMA connectors and an  
anodized aluminum heat sink, enclosing a welded module for reliable, long-term performance.  
Feature  
Advantages  
0.1 dB typ. mainline loss  
Extremely low internal power dissipation, reducing mainline loss and internal temperature for high reliability  
0.2 dB coupling ꢀatness  
Provides highly accurate sampling of signal power  
VSWR 1.1:1 typ  
Excellent 50impedance matching minimizes interference with signal integrity  
DC Pass up to 3A  
100 W input maximum  
Suitable for applications using remote antenna control or other remote motorized requirements  
High power capacity, combined with excellent insertion loss and VSWR, supports operation in transmitters  
and base stations for amateur radio, PMR, FM, broadcast TV, aviation, and military applications  
Notes  
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.  
B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuits applicable established test performance criteria and measurement instructions.  
C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, Standard Terms”); Purchasers of this part are entitled  
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp  
®
Mini-Circuits  
www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com  
Page 1 of 2  
26 dB DC Pass  
High Power Signal Tap  
ZARC-26-12+  
50Ω  
100W  
20 to 100 MHz  
Features  
Maximum Ratings  
Operating Temperature  
-40°C to 85°C  
-55°C to 100°C  
100W max.  
3A  
• excellent mainline loss, 0.1 dB typ.  
• very ꢀat coupling 0.2 dB typ.  
• excellent VSWR, 1.1 typ.  
CASE STYLE: AW1564  
Connectors Model  
Storage Temperature  
Power Input  
SMA  
ZARC-26-12-S+  
DC Current (IN-OUT)  
Permanent damage may occur if any of these limits are exceeded.  
Applications  
• instrumentation  
• amateur radio  
+RoHS Compliant  
The +Suffix identifies RoHS Compliance. See our web site  
for RoHS Compliance methodologies and qualifications  
Coaxial Connections  
INPUT  
1
2
3
OUTPUT  
COUPLED  
Electrical Specifications at 25°C  
Parameter  
Condition (MHz)  
Min.  
Typ.  
Max.  
Unit  
20  
100  
0.10  
0.15  
0.20  
MHz  
Frequency Range  
20  
60  
0.03  
0.06  
0.10  
26.3  
26.2  
26.3  
26.4  
0.05  
0.10  
36  
Outline Drawing  
dB  
dB  
Mainline Loss (above theoretical 0.011 dB)  
Coupling* (IN-CPL, OUT-CPL)  
100  
20 - 100  
20  
25.9  
25.8  
25.6  
26.6  
26.8  
27.2  
0.20  
0.25  
60  
100  
20 - 60  
60 - 100  
20  
dB  
dB  
Coupling Flatness(±)  
Return Loss (Input)  
25  
60  
20  
27  
100  
20  
18  
23  
25  
36  
60  
20  
27  
dB  
Return Loss (Output)  
100  
20  
18  
23  
inch  
Outline Dimensions ( mm  
)
25  
45  
A
B
C
D
E
F
1.525  
38.74  
G
.125  
3.18  
60  
25  
34  
dB  
W
Return Loss (Coupling)  
3.00  
2.06  
2.03  
.10 2.500  
100  
20 - 100  
20  
30  
76.20 52.32 51.56  
2.54 63.50  
100  
Input Power  
H
.50  
J
.50  
K
.50  
L
2.00  
M
1.00  
N
wt  
* Coupling can be used for both forward and reversed direction.  
2.00 grams  
50.80 230  
12.70 12.70 12.70 50.80 25.40  
Typical Performance Data  
Frequency  
(MHz)  
Mainline Loss  
(dB)  
Coupling  
(dB)  
Return Loss  
(dB)  
Out  
Electrical Schematic  
In-Out  
In  
Cpl  
In-Cpl  
Out-Cpl  
20.00  
30.00  
40.00  
50.00  
60.00  
70.00  
80.00  
90.00  
95.00  
100.00  
0.03  
0.03  
0.04  
0.04  
0.05  
0.05  
0.06  
0.06  
0.07  
0.07  
26.23  
26.21  
26.23  
26.24  
26.26  
26.27  
26.28  
26.28  
26.28  
26.28  
26.23  
26.22  
26.24  
26.27  
26.28  
26.31  
26.33  
26.35  
26.36  
26.37  
43.05  
40.25  
37.78  
36.20  
34.69  
33.39  
32.20  
31.24  
30.73  
30.29  
42.30  
39.82  
37.57  
35.75  
34.33  
33.15  
31.90  
30.91  
30.51  
30.05  
47.14  
41.93  
38.81  
36.68  
34.95  
33.47  
32.19  
31.06  
30.54  
30.04  
ZARC-26-12+  
COUPLING  
ZARC-26-12+  
RETURN LOSS  
ZARC-26-12+  
MAINLINE LOSS  
at RF level of -10 dBm  
at RF level of -10 dBm  
at RF level of -10 dBm  
0.10  
0.08  
0.06  
0.04  
0.02  
0.00  
60  
50  
40  
30  
20  
10  
60  
50  
40  
30  
20  
10  
0
IN  
OUT  
CPL  
IN-CPL  
OUT-CPL  
20  
40  
60  
80  
100  
20  
40  
60  
80  
100  
20  
40  
60  
FREQUENCY (MHz)  
80  
100  
FREQUENCY (MHz)  
FREQUENCY (MHz)  
Notes  
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.  
B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuits applicable established test performance criteria and measurement instructions.  
REV. A  
M151107  
C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, Standard Terms”); Purchasers of this part are entitled  
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp  
ED-14165/1  
ZARC-26-12+  
CH/CP/AM  
151007  
Page 2 of 2  
®
Mini-Circuits  
www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com  

相关型号:

ZARC-26-12+

High Power Signal Tap
MINI

ZARC-26-12-S+

High Power Signal Tap
MINI

ZAS-1

SPST, 5MHz Min, 450MHz Max, 4.7dB Insertion Loss-Max, CASE M22
MINI

ZAS-1+

SPST, 5MHz Min, 450MHz Max, 4.7dB Insertion Loss-Max, CASE M22
MINI

ZAS-1B

SPST, 5MHz Min, 450MHz Max, 4.7dB Insertion Loss-Max, CASE M22
MINI

ZAS-1BR

SPST, 5MHz Min, 450MHz Max, 4.7dB Insertion Loss-Max, CASE M22
MINI

ZAS-3

Attenuator/Switch
MINI

ZAS-3BR

SPST, 1MHz Min, 200MHz Max, 2.5dB Insertion Loss-Max, CASE M22
MINI

ZASC-ED8005/1

Combiner, 1MHz Min, 500MHz Max, 3.76dB Insertion Loss-Max, CASE F14
MINI

ZASC-ED8005/1+

Combiner, 1MHz Min, 500MHz Max, 3.76dB Insertion Loss-Max, CASE F14
MINI

ZASW-2-50DR

SWITCHES VERY HIGH ISOLATION, SPDT, DC to 5 GHz
MINI

ZASW-2-50DRA+

Diversity Switch,
MINI