ZFM-2 [MINI]

Frequency Mixer;
ZFM-2
型号: ZFM-2
厂家: MINI-CIRCUITS    MINI-CIRCUITS
描述:

Frequency Mixer

文件: 总2页 (文件大小:262K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
FCoraxeiaql uency Mixer  
ZFM-2+  
ZFM-2  
Level 7 (LO Power +7 dBm) 1 to 1000 MHz  
Maximum Ratings  
Operating Temperature  
Storage Temperature  
RF Power  
Features  
-55°C to 100°C  
-55°C to 100°C  
50mW  
• low conversion loss, 5.72 dB typ.  
• good L-R isolation, 40 dB typ, L-I, 35 dB typ.  
• wideband, 1 to 1000  
SMA version shown  
CASE STYLE: K18  
Connectors Model  
• rugged shielded case  
IF Current  
40mA  
BNC  
SMA  
ZFM-2(+)  
ZFM-2-S+  
Applications  
• VHF/UHF  
• cellular  
Permanent damage may occur if any of these limits are exceeded.  
BRACKET (OPTION “B”)  
Coaxial Connections  
+RoHS Compliant  
The +Suffix identifies RoHS Compliance. See our web site  
for RoHS Compliance methodologies and qualifications  
LO  
RF  
IF  
1
2
3
• instrumentation  
Electrical Specifications  
FREQUENCY  
(MHz)  
CONVERSION LOSS  
LO-RF ISOLATION  
LO-IF ISOLATION  
(dB)  
(dB)  
(dB)  
Outline Drawing  
Mid-Band  
LO/RF  
fL-fU  
IF  
m
L
M
U
L
M
U
Total  
Range  
X
σ
Max. Max.  
Typ.  
50  
Min.  
45  
Typ.  
40  
Min.  
25  
Typ.  
30  
Min.  
25  
Typ.  
45  
Min.  
40  
Typ.  
35  
Min.  
25  
Typ.  
25  
Min.  
20  
1-1000  
DC-1000 5.72 0.06 7.5  
8.5  
1 dB COMP.: +1 dBm typ.  
L = low range [fL to 10 fL]  
m= mid band [2fL to fU/2]  
M = mid range [10 fL to fU/2]  
U = upper range [fU/2 to fU]  
Typical Performance Data  
Frequency  
(MHz)  
Conversion  
Isolation  
L-R  
(dB)  
Isolation  
VSWR  
RF Port  
(:1)  
VSWR  
LO Port  
(:1)  
Loss  
(dB)  
L-I  
(dB)  
LO  
LO  
LO  
LO  
LO  
RF  
LO  
+7dBm  
+7dBm  
+7dBm  
+7dBm  
+7dBm  
1.00  
2.00  
31.00  
32.00  
35.00  
40.00  
50.00  
7.23  
6.50  
5.80  
5.62  
5.68  
>67.00  
>67.00  
>67.00  
>67.00  
>67.00  
>67.00  
>67.00  
>67.00  
>67.00  
>67.00  
1.30  
1.15  
1.07  
1.06  
1.07  
2.70  
2.63  
2.77  
2.55  
2.41  
5.00  
10.00  
20.00  
Outline Dimensions ( inch  
)
50.00  
80.00  
70.00  
137.34  
203.87  
270.40  
5.58  
5.53  
5.57  
5.72  
5.45  
61.94  
54.33  
48.65  
45.10  
42.56  
63.74  
54.76  
47.61  
43.03  
40.00  
1.09  
1.11  
1.16  
1.18  
1.20  
2.37  
2.29  
2.20  
2.16  
2.13  
mm  
100.00  
167.34  
233.87  
300.40  
A
1.25  
B
C
D
E
F
G
H
1.25  
.75  
.63  
.38  
1.00  
.125 1.000  
31.75 31.75 19.05 16.00  
9.65 25.40  
3.18 25.40  
366.94  
466.74  
500.00  
599.81  
666.34  
336.94  
436.74  
470.00  
569.81  
636.34  
5.73  
5.82  
5.72  
6.02  
6.11  
40.45  
38.33  
38.80  
37.43  
37.94  
37.57  
34.32  
34.10  
32.81  
31.57  
1.22  
1.23  
1.26  
1.29  
1.34  
2.06  
2.13  
2.09  
2.09  
2.04  
J
--  
--  
K
--  
--  
L
M
N
2.18  
P
.75  
Q
wt  
.07 grams  
1.78 70.0  
.125 1.688  
3.18 42.88 55.37 19.05  
799.41  
832.68  
899.21  
932.48  
1000.00  
769.41  
802.68  
869.21  
902.48  
969.00  
6.27  
6.46  
7.00  
7.37  
7.63  
36.06  
35.22  
33.77  
33.17  
32.49  
29.67  
28.79  
26.14  
25.03  
23.59  
1.40  
1.47  
1.55  
1.66  
1.72  
2.13  
2.19  
2.24  
2.28  
2.30  
Electrical Schematic  
Notes  
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.  
B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuits applicable established test performance criteria and measurement instructions.  
C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, Standard Terms”); Purchasers of this part are entitled  
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp  
REV. C  
M151107  
ZFM-2  
DJ/TD/CP  
151008  
®
Page 1 of 2  
Mini-Circuits  
www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com  
ZFM-2+  
ZFM-2  
Performance Charts  
ZFM-2  
ZFM-2  
CONVERSION LOSS  
L-R ISOLATION  
at IF Freq of 30 MHz  
10.0  
80  
70  
60  
50  
40  
30  
20  
LO=+4 dBm  
LO=+7 dBm  
LO=+10 dBm  
LO=+4 dBm  
LO=+7 dBm  
LO=+10 dBm  
9.0  
8.0  
7.0  
6.0  
5.0  
4.0  
0
200  
400  
600  
800  
1000  
1000  
1000  
0
200  
400  
600  
800  
1000  
FREQUENCY (MHz)  
FREQUENCY (MHz)  
ZFM-2  
L-I ISOLATION  
ZFM-2  
RF VSWR  
2.0  
1.8  
1.6  
1.4  
1.2  
1.0  
80  
70  
60  
50  
40  
30  
20  
LO=+4 dBm  
LO=+7 dBm  
LO=+10 dBm  
LO=+4 dBm  
LO=+7 dBm  
LO=+10 dBm  
0
200  
400  
600  
800  
1000  
0
200  
400  
600  
800  
FREQUENCY (MHz)  
FREQUENCY (MHz)  
ZFM-2  
IF VSWR  
ZFM-2  
LO VSWR  
3.0  
2.5  
2.0  
1.5  
1.0  
5.0  
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
LO=+4 dBm  
LO=+7 dBm  
LO=+10 dBm  
LO=+4 dBm  
LO=+7 dBm  
LO=+10 dBm  
0
200  
400  
600  
800  
1000  
0
200  
400  
600  
800  
FREQUENCY (MHz)  
FREQUENCY (MHz)  
Notes  
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.  
B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuits applicable established test performance criteria and measurement instructions.  
C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, Standard Terms”); Purchasers of this part are entitled  
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp  
®
Page 2 of 2  
Mini-Circuits  
www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com  

相关型号:

ZFM-2+

Frequency Mixer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-2-S+

Frequency Mixer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-2B

Double Balanced Mixer, 1MHz Min, 1000MHz Max, 8.5dB Conversion Loss-Max, CASE K18

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-2B-S

Double Balanced Mixer, 1MHz Min, 1000MHz Max, 8.5dB Conversion Loss-Max, CASE K18

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-2H

Double Balanced Mixer, 5MHz Min, 1000MHz Max, 10dB Conversion Loss-Max, CASE K18

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-2H+

Frequency Mixer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-2H-S+

Frequency Mixer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-2HB+

Double Balanced Mixer, 5MHz Min, 1000MHz Max, 10dB Conversion Loss-Max, ROHS COMPLIANT, CASE K18

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-2HB-S

Double Balanced Mixer, 5MHz Min, 1000MHz Max, 10dB Conversion Loss-Max, CASE K18

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-2HB-S+

Double Balanced Mixer, 5MHz Min, 1000MHz Max, 10dB Conversion Loss-Max, ROHS COMPLIANT, CASE K18

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-3

Frequency Mixer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI

ZFM-3+

Frequency Mixer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MINI