MKWI10-48S48C [MINMAX]

DC-DC Power Module 10W;
MKWI10-48S48C
型号: MKWI10-48S48C
厂家: MINMAX TECHNOLOGY CO., LTD.    MINMAX TECHNOLOGY CO., LTD.
描述:

DC-DC Power Module 10W

文件: 总6页 (文件大小:786K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
MKWI10C SERIES  
DC-DC Power Module 10W  
FEATURES  
Fully Encapsulated Plastic Case for Chassis and DIN-Rail Mounting Version  
Ultra-wide 4:1 Input Voltage Range  
Fully Regulated Output Voltage  
High Efficiency up to 86%  
I/O Isolation 3000 VDC  
Operating Ambient Temp. Range -40°C to +92.5°C  
No Min. Load Requirement  
Under-voltage, Overload and Short Circuit Protection  
Remote On/Off Control  
EMI Emission EN 55032 Class A & FCC Level A Approved (Pending)  
EMC Immunity EN 61000-4-2,3,4,5,6,8 Approved (Pending)  
UL/cUL/IEC/EN 62368-1 Safety Approval & CE Marking  
PRODUCT OVERVIEW  
The MINMAX MKWI10C series is a new range of high performance DC-DC converters featuring a wide 4:1 input range in a chassis-mount package with  
terminal strip connections and optional DIN-Rail mounting offer system designers the opportunity to eliminate the power board request in the field  
application.  
Further features including high efficiency 86%; wide operating temp. range by -40to +92.5; I/O isolation 3000VDC for 60Sec; no min. load request;  
built-in EMC filter for EMI emission EN 55032 class A and EMS immunity EN 61000-4-2,3,4,5,6,8 approved; and abnormal operation protection with under-  
voltage, overload and short circuit protections.  
All family have been qualified per CB scheme with safety approvals to UL/cUL/IEC/EN 62368-1 with 3 years warranty.  
Model Selection Guide  
Input  
Voltage  
(Range)  
VDC  
Output  
Output  
Current  
Max.  
mA  
Input Current  
Max. capacitive  
Load  
Efficiency  
Voltage  
(typ.)  
Model Number  
@Max. Load  
@No Load  
mA(typ.)  
@Max. Load  
VDC  
5
mA(typ.)  
496  
506  
484  
484  
484  
495  
484  
484  
489  
248  
253  
242  
242  
242  
248  
242  
242  
245  
μF  
1000  
1000  
470  
%
MKWI10-24S05C  
MKWI10-24S051C  
MKWI10-24S12C  
MKWI10-24S15C  
MKWI10-24S24C  
MKWI10-24S48C  
MKWI10-24D12C  
MKWI10-24D15C  
MKWI10-24D24C  
MKWI10-48S05C  
MKWI10-48S051C  
MKWI10-48S12C  
MKWI10-48S15C  
MKWI10-48S24C  
MKWI10-48S48C  
MKWI10-48D12C  
MKWI10-48D15C  
MKWI10-48D24C  
2000  
2000  
833  
84  
84  
86  
86  
86  
84  
86  
86  
85  
84  
84  
86  
86  
86  
84  
86  
86  
85  
5.1  
12  
15  
666  
330  
24  
(9 ~ 36)  
24  
416  
30  
150  
48  
208  
68  
±12  
±15  
±24  
5
±416  
±333  
±208  
2000  
2000  
833  
220#  
150#  
68#  
1000  
1000  
470  
5.1  
12  
15  
666  
330  
48  
(18 ~ 75)  
24  
416  
20  
150  
48  
208  
68  
±12  
±15  
±24  
±416  
±333  
±208  
220#  
150#  
68#  
# For each output  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2018/10/08 REV:5 Page 1 of 6  
®
MKWI10C SERIES  
DC-DC Power Module 10W  
Input Specifications  
Parameter  
Conditions / Model  
24V Input Models  
48V Input Models  
24V Input Models  
48V Input Models  
24V Input Models  
Min.  
-0.7  
-0.7  
---  
Typ.  
---  
---  
---  
---  
8
Max.  
50  
Unit  
Input Surge Voltage (1 sec. max.)  
Start-Up Threshold Voltage  
Under Voltage Shutdown  
100  
9
VDC  
ms  
---  
18  
---  
---  
48V Input Models  
Nominal Vin and Constant Resistive Load  
All Models  
---  
---  
16  
---  
---  
60  
Start Up Time (Power On)  
Input Filter  
Internal Pi Type  
Remote On/Off Control  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Unit  
Converter On  
3.5V ~ 12V or Open Circuit  
Converter Off  
0~1.2V or Short Circuit (Pin 1 and Pin 2)  
Control Input Current (on)  
Control Input Current (off)  
Control Common  
Vctrl = 5V  
Vctrl = 0V  
---  
---  
---  
500  
μA  
μA  
---  
Referenced to Negative Input  
---  
-500  
Standby Input Current  
2.5  
---  
mA  
Output Specifications  
Parameter  
Conditions / Model  
Min.  
---  
Typ.  
---  
Max.  
±2.0  
±2.0  
±0.5  
±0.5  
±5.0  
Unit  
Output Voltage Setting Accuracy  
Output Voltage Balance  
Line Regulation  
%Vnom.  
Dual Output, Balanced Loads  
Vin=Min. to Max. @Full Load  
Io=0% to 100%  
---  
±1.0  
---  
%
%
%
%
---  
Load Regulation  
---  
---  
Load Cross Regulation (Dual Output Models)  
Minimum Load  
Asymmetrical Load 25/100% Full Load  
---  
---  
No minimum Load Requirement  
24V & ±24V & 48V Output Models  
Other Output Models  
---  
---  
---  
---  
---  
---  
180  
90  
---  
---  
mV P-P  
mV P-P  
μsec  
%
Ripple & Noise  
0-20 MHz Bandwidth  
Transient Recovery Time  
Transient Response Deviation  
Temperature Coefficient  
Over Load Protection  
---  
500  
±5  
25% Load Step Change  
±3  
±0.01  
150  
±0.02  
---  
%/  
%
Hiccup  
Short Circuit Protection  
Hiccup Mode 0.7Hz typ., Automatic Recovery  
General Specifications  
Parameter  
Conditions  
60 Seconds  
500 VDC  
Min.  
3000  
1000  
---  
Typ.  
---  
Max.  
---  
Unit  
VDC  
MΩ  
I/O Isolation Voltage  
I/O Isolation Resistance  
I/O Isolation Capacitance  
Switching Frequency  
MTBF (calculated)  
---  
---  
100kHz, 1V  
2200  
330  
---  
---  
pF  
---  
---  
kHz  
MIL-HDBK-217F@25, Ground Benign  
4,132,899  
---  
Hours  
Safety Approvals  
UL/cUL 62368-1 recognition(UL certificate), IEC/EN 62368-1 & 60950-1(CB report)  
Environmental Specifications  
Parameter  
Min.  
-40  
Max.  
Unit  
Operating Ambient Temperature Range  
(See Power Derating Curve)  
Case Temperature  
+92.5  
---  
-50  
---  
+105  
+125  
95  
% rel. H  
Storage Temperature Range  
Humidity (non condensing)  
Lead Temperature (1.5mm from case for 10Sec.)  
---  
260  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2018/10/08 REV:5 Page 2 of 6  
®
MKWI10C SERIES  
DC-DC Power Module 10W  
EMC Specifications  
Standards & Level  
EN 55032, FCC part 15  
Parameter  
Performance  
Class A  
EMI  
Conduction & Radiation  
EN55035  
Direct discharge  
EN61000-4-2 Air ± 8kV, Contact ± 6kV  
EN61000-4-3 10V/m  
Indirect discharge HCP & VCP  
ESD  
Contact ± 6kV  
A
A
A
A
A
A
Radiated immunity  
Fast transient  
Surge  
EMS  
EN61000-4-4 ±2kV  
EN61000-4-5 ±2kV  
EN61000-4-6 10Vrms  
EN61000-4-8 100A/m  
Conducted immunity  
PFMF  
Power Derating Curve  
Notes  
1
2
3
4
5
Specifications typical at Ta=+25, resistive load, nominal input voltage and rated output current unless otherwise noted.  
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%  
We recommend to protect the converter by a slow blow fuse in the input supply line.  
Other input and output voltage may be available, please contact factory.  
Specifications are subject to change without notice.  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2018/10/08 REV:5 Page 3 of 6  
®
MKWI10C SERIES  
DC-DC Power Module 10W  
Package Specifications  
Mechanical Dimensions  
Pin Connections  
Pin  
Single Output  
Remote On/Off  
Dual Output  
Remote On/Off  
-Vin  
1
2
3
4
5
6
-Vin  
X
2.3  
4
+Vin  
+Vin  
-Vout  
-Vout  
6
3
2
1
NC  
Common  
+Vout  
5
4
Top view  
Indication LED  
+Vout  
-
DC  
ON  
NC: No Connection  
POWER" GOOD" INDICATOR  
71. 0[2.80]  
79. 0[3.11]  
10. 0[0.39]  
58. 4[2.30]  
All dimensions in mm (inches)  
Tolerance: X.X±0.5 (X.XX±0.02)  
59. 0[2.32]  
X.XX±0.25 ( X.XXX±0.01)  
Physical Characteristics  
Case Size  
Case Material  
Weight  
:
:
:
79.0x34.0x22.0mm (3.11x1.10x0.87 inches)  
Plastic resin (flammability to UL 94V-0 rated)  
65.76g  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2018/10/08 REV:5 Page 4 of 6  
®
MKWI10C SERIES  
DC-DC Power Module 10W  
Package Specifications with DIN Rail Mounting Bracket (order code AC-DIN-05)  
Mechanical Dimensions  
DIN-Rail Mounting Kit  
X
4
2.3  
6
3
2
1
5
4
Top view  
-
DC  
ON  
Indication LED  
71.0 [2.80]  
79.0 [3.11]  
87.6 [3.45]  
POWER "GOOD" INDICATOR  
59.0 [2.32]  
10.0 [0.39]  
Physical Characteristics  
Case Size  
Case Material  
Weight  
:
:
:
79.0x34.0x22.0mm (3.11x1.10x0.87 inches)  
Plastic resin (flammability to UL 94V-0 rated)  
108.76g  
Order Code Table  
Standard  
DIN Rail  
Converter With DIN Rail Mounting  
MKWI10-24S05C  
MKWI10-24S051C  
MKWI10-24S12C  
MKWI10-24S15C  
MKWI10-24S24C  
MKWI10-24S48C  
MKWI10-24D12C  
MKWI10-24D15C  
MKWI10-24D24C  
MKWI10-48S05C  
MKWI10-48S051C  
MKWI10-48S12C  
MKWI10-48S15C  
MKWI10-48S24C  
MKWI10-48S48C  
MKWI10-48D12C  
MKWI10-48D15C  
MKWI10-48D24C  
MKWI10-24S05C-DIN05  
MKWI10-24S051C-DIN05  
MKWI10-24S12C-DIN05  
MKWI10-24S15C-DIN05  
MKWI10-24S24C-DIN05  
MKWI10-24S48C-DIN05  
MKWI10-24D12C-DIN05  
MKWI10-24D15C-DIN05  
MKWI10-24D24C-DIN05  
MKWI10-48S05C-DIN05  
MKWI10-48S051C-DIN05  
MKWI10-48S12C-DIN05  
MKWI10-48S15C-DIN05  
MKWI10-48S24C-DIN05  
MKWI10-48S48C-DIN05  
MKWI10-48D12C-DIN05  
MKWI10-48D15C-DIN05  
MKWI10-48D24C-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
AC-DIN05  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2018/10/08 REV:5 Page 5 of 6  
®
MKWI10C SERIES  
DC-DC Power Module 10W  
Test Setup  
Peak-to-Peak Output Noise Measurement Test  
Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between  
50 mm and 75 mm from the DC-DC Converter.  
Copper Strip  
Cout  
+Vin  
+Out  
Copper Strip  
Cout  
+Vin  
+Out  
Com.  
-Out  
Scope  
Scope  
Single Output  
DC / DC  
Converter  
Dual Output  
DC / DC  
Converter  
Resistive  
Load  
Resistive  
Load  
Scope  
Copper Strip  
Cout  
-Vin  
-Out  
Copper Strip  
-Vin  
Copper Strip  
Technical Notes  
Remote On/Off  
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off,  
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent. A logic  
low is 0V to 1.2V. A logic high is 3.5V to 12V. The maximum sink current at the on/off terminal (Pin 1) during a logic low is -500μA.  
Overload Protection  
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited  
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back  
into its specified range.  
Input Source Impedance  
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.  
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.  
By using a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 4.7μF for the 24V input devices and a 2.2μF for the 48V devices,  
capacitor mounted close to the power module helps ensure stability of the unit.  
+
+Vin  
+Out  
+
DC / DC  
Converter  
DC Power  
Source  
Load  
Cin  
-
-Vin  
-Out  
Output Ripple Reduction  
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is  
recommended to use 3.3μF capacitors at the output.  
+
+Vin  
+Out  
+
+Vin  
+Out  
Single Output  
DC / DC  
Converter  
Load  
Load  
Dual Output  
DC / DC Com.  
Converter  
DC Power  
Source  
Cout  
Cout  
DC Power  
Source  
Cout  
Load  
-
-Vin  
-Out  
-
-Vin  
-Out  
Maximum Capacitive Load  
The MKWI10C series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up,  
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the  
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105.  
The derating curves are determined from measurements obtained in a test setup.  
Position of air velocity  
probe and thermocouple  
Air Flow  
50mm / 2in  
15mm / 0.6in  
DUT  
Minmax Technology Co., Ltd.  
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan  
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw  
2018/10/08 REV:5 Page 6 of 6  

相关型号:

MKWI10C

DC-DC Power Module 10W
MINMAX

MKWI40

Smallest Encapsulated 40W Converter
TOTAL-POWER

MKWI40

DC/DC CONVERTER 40W, Highest Power Density
MINMAX

MKWI40-24D12

Smallest Encapsulated 40W Converter
TOTAL-POWER

MKWI40-24D12

DC/DC CONVERTER 40W, Highest Power Density
MINMAX

MKWI40-24D15

Smallest Encapsulated 40W Converter
TOTAL-POWER

MKWI40-24D15

DC/DC CONVERTER 40W, Highest Power Density
MINMAX

MKWI40-24S033

Smallest Encapsulated 40W Converter
TOTAL-POWER

MKWI40-24S033

DC/DC CONVERTER 40W, Highest Power Density
MINMAX

MKWI40-24S05

Smallest Encapsulated 40W Converter
TOTAL-POWER

MKWI40-24S05

DC/DC CONVERTER 40W, Highest Power Density
MINMAX

MKWI40-24S12

Smallest Encapsulated 40W Converter
TOTAL-POWER