DRL-SIE-SWF [MOLEX]

DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Parallel Dongle Protection; 的DirectLink SW1000软件驱动程序西门子S5 , S7 , TI - 全部标记 - 并口加密狗保护
DRL-SIE-SWF
型号: DRL-SIE-SWF
厂家: Molex    Molex
描述:

DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Parallel Dongle Protection
的DirectLink SW1000软件驱动程序西门子S5 , S7 , TI - 全部标记 - 并口加密狗保护

驱动
文件: 总3页 (文件大小:831K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
This document was generated on 05/18/2010  
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION  
Part Number:  
Status:  
1120275013  
Active  
EU RoHS  
ELV and RoHS  
Compliant  
REACH SVHC  
China RoHS  
Description:  
DirectLink™ SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Parallel  
Dongle Protection  
Not Reviewed  
Halogen-Free  
Status  
Documents:  
Drawing (PDF)  
RoHS Certificate of Compliance (PDF)  
Not Reviewed  
Need more information on product  
environmental compliance?  
General  
Product Family  
Series  
Software and Development Kits  
112027  
SW1000 integrates a powerful Console for  
configuration, diagnostic with test tools, and data  
Email productcompliance@molex.com  
For a multiple part number RoHS Certificate of  
Compliance, click here  
Comments  
servers (OPC DA, SuiteLink/FastDDE, library DLL).  
Ethernet TCP/IP: . - Siemens - Industrial Ethernet . .  
Serial: . - Siemens - AS511, PPI/PPI+, TI-Dir  
Yes  
Please visit the Contact Us section for any  
non-product compliance questions.  
DLL/API Available  
Engineering Console  
Functionality  
Yes  
Client / Server, Master  
Operating System  
Windows 7, Windows Server 2003, Windows Server  
2008, Windows Vista, Windows XP  
Direct-Link®  
EtherNet TCP/IP, Serial  
Search Parts in this Series  
112027Series  
Product Name  
Protocol  
Source Code  
Specification Compliance  
N/A  
N/A  
Material Info  
Old Part Number  
DRL-SIE-SWF-P  
DRL-SIE-SWF-*  
Reference - Drawing Numbers  
Sales Drawing  
This document was generated on 05/18/2010  
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION  
Direct-Link™ communication drivers provide data  
acquisition between Windows based applications and  
industrial devices connected to Ethernet TCP/IP and  
Serial networks.  
21 Jan. 10  
DW200594  
Direct-Link™ SW1000  
Economical and Reliable Industrial Communications  
Features  
Well suited for embedded and  
light architecture (laptop,  
panel PC, MMI)  
Uses Standard PC resources  
X Ethernet port  
X Serial port (COM1, COM2)  
100% software solution  
Data Servers:  
X OPC DA v3.0, 2.05 and 1.0a  
X Wonderware DAServer  
X Wonderware I/O  
(SuiteLink/FastDDE)  
X ActiveX Control  
Overview  
X Library DLL  
Direct-Link™ SW1000 is a complete software package designed to connect your  
computer to Industrial Ethernet TCP/IP and Serial networks.  
Supports multi Ethernet TCP/IP  
protocols simultaneously  
Direct-Link™ SW1000 is well adapted for embedded environments and it is used  
by operator interface manufacturers and OEM equipment manufacturers needing  
to make their computerized systems communicate.  
Protection  
X Software key  
Direct-Link™ SW1000 is ideally suited for small and medium-sized applications  
with low time constraints. It easily adapts to the light architectures of laptops,  
operator interfaces and workstations. Widely adopted in Industry, Direct-Link™  
solutions are used for technical management in the building sector, electrical  
installations, tests and measurement.  
X Dongle (Parallel or USB)  
Database (32Kbits, 32 Kwords)  
for Server mode to exchange  
data with applications  
To collect data, SW1000 uses existing computer resources (Ethernet port, COM  
ports) to connect a broad range of control and sensor devices from Allen-Bradley,  
Siemens, Schneider, and many others.  
Economical and easy-to-use, the SW1000 package is designed for Windows  
PC-Based applications (HMI, SCADA, MES, RDBM, custom developments, etc),  
which require reliable data exchange with plant floor.  
Supported OS  
Windows 32-bits  
(2003 Server / XP SP2 / 2000  
SP4 / NT 4.0 SP6)  
Available in Windows 2003 server, XP, 2000 and NT 4.0 environments, Direct-  
Link™ SW1000 integrates a powerful Console for configuration, diagnostic and  
test tools and data servers (OPC DA, DAServer, SuiteLink/FastDDE, ActiveX  
control, library DLL), that provide information for client applications.  
Compatible with  
Direct-Link™ SW1000  
Software tools  
Protocols (all included in the package)  
Direct-Link™ products lie in effective  
software tools enabling fast integration  
of industrial communication into your  
applications.  
Ethernet TCP/IP - All protocols can run simultaneously  
C/S(1)(2)  
New Allen-Bradley - Logix5000 messaging for (ControlLogix and  
FlexLogix)  
Altus - Alnet II (AL2000 and WebGate Series)  
Alstom - SRTP (Alspa C80-35 and C80-75 Series)  
GE Fanuc - SRTP (90-30 and 90-70 Series)  
Mitsubishi - Melsec (A and Q Series)  
C/S  
C/S  
C/S  
C/S  
C/S  
C/S  
C/S  
C/S  
Omron - FINS (C, CV and CS Series)  
Schneider - Open Modbus TCP/UDP (Premium and Quantum Series)  
Schneider - Uni-TE (Micro and Premium)  
Siemens - Industrial Ethernet (S5, S7 and TI-505 Series)  
Serial  
Modbus ASCII & RTU  
M/S  
M
S, C/S  
M
M
M
GE Fanuc – SNPX (90-xx and 80-xx Series)  
Schneider – Uni-Telway (TSX 7 Series)  
Siemens – AS511 (Simatic S5 Series)  
Siemens – PPI/PPI+ (Simatic S7-200 Series)  
Siemens – Ti-Dir (Simatic TI-505 Series)  
- Configuration Software -  
M: Master - S: Slave - M/S: Master/Slave - C/S: Client/Server - C: Client  
(1): Library DLL and DAServer are not supported with the Logix5000 messaging.  
(2): Server mode via PCCC messaging  
Ordering Information  
SAP  
Part Number  
Product description  
Direct-Link™ SW1000 software package.  
All protocols and data servers included.  
Ethernet TCP/IP 1000 tags + Serial Full tags.  
Direct-Link™ SW1000 software package.  
All protocols and data servers included.  
Ethernet TCP/IP Full tags + Serial Full tags.  
Direct-Link™ SW1000 software package.  
Siemens protocols (S5, S7, TI) and data  
servers included.  
DRL-ALL-SWL-P  
DRL-ALL-SWL-S  
DRL-ALL-SWL-U  
1120270004 (P)  
1120270005 (S)  
1120270006 (U)  
- OPC Browser -  
DRL-ALL-SWF-P  
DRL-ALL-SWF-S  
DRL-ALL-SWF-U  
1120270001 (P)  
1120270002 (S)  
1120270003 (U)  
DRL-SIE-SWF-P  
DRL-SIE-SWF-S  
DRL-SIE-SWF-U  
1120270013 (P)  
1120270014 (S)  
1120270015 (U)  
Ethernet TCP/IP Full tags + Serial Full tags.  
Direct-Link™ SW1000 upgrade from 1000  
tags to Full tags  
DRL-UPG-SWF  
1120270010  
(*): to order, replace X with the corresponding letter below.  
Replace X  
Type of protection  
P
S
U
Dongle for parallel port (small format)  
Software Key  
Dongle for USB port (not supported on NT 4)  
The performance of SW1000 depends on the operating system and the characteristics of your  
PC (processor, memory, etc). If in the future, your application requires increased performance,  
it is very easy to migrate SW1000 to applicom® solutions based on intelligent network  
interface cards (on-board processor managing industrial protocols, multi communication  
channels up to 32, embedded electrical interfaces RS232/RS422/RS485/Current loop).  
- Network Diagnostics & Test Tools -  
Other related products: IP67/IP20 Ethernet switches, Intelligent Ethernet card and gateways,  
Ethernet I/O for control/command.  
To contact us: www.woodhead.com  
North America: US: + 1 800 225 7724 – Canada: +1 519 725 5136  
Europe:  
France: +33 2 32 96 04 20 – Germany: +49 7252 94 96 0– Italy: +39 010 59 30 77 –  
United Kingdom: +44 1495 356300  
Asia:  
Shanghai, China: +86 21-5835-9885 - Tianjin, China: +86 22-23321717  
Singapore: +65 6268-6868 – Yamato, Japan: +81 46-265-2428 – Nagoya, Japan: +81 52-221-5950  
Brad is a registered trademark and BradCommunications and applicom are trademarks of Molex Incorporated. © 2008 Molex  

相关型号:

DRL-SIE-SWF-P

DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Parallel Dongle Protection
MOLEX

DRL-SIE-SWF-S

DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Software Key Protection
MOLEX

DRL-SIE-SWF-U

DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - USB Dongle Protection
MOLEX

DRL09P

D Type Connector, 9 Contact(s), Male, 0.109 inch Pitch, Solder Terminal, #4-40, Receptacle
AUK

DRL09S

D Type Connector, 9 Contact(s), Female, 0.109 inch Pitch, Solder Terminal, #4-40, Plug
AUK

DRL09SN

D Type Connector, 9 Contact(s), Female, 0.109 inch Pitch, Solder Terminal, #4-40, Plug
AUK

DRL10-12-1

AC-DC电源
TDK

DRL10-24-1

AC-DC电源
TDK

DRL100-24-1

AC-DC电源
TDK

DRL100-24-1/C2

AC-DC电源
TDK

DRL30-12-1

AC-DC电源
TDK

DRL30-15-1

AC-DC电源
TDK