E-112073-0001 [MOLEX]
BradCommunications SST 1 Ethernet and 2 Serial ports PLC communications module; BradCommunications SST 1个以太网和2个串行端口, PLC通信模块型号: | E-112073-0001 |
厂家: | Molex |
描述: | BradCommunications SST 1 Ethernet and 2 Serial ports PLC communications module |
文件: | 总3页 (文件大小:2355K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
This document was generated on 06/07/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
Part Number:
Status:
1120730001
Active
EU RoHS
ELV and RoHS
Compliant
REACH SVHC
China RoHS
Description:
BradCommunications™ SST™ 1 Ethernet and 2 Serial ports PLC communications
module for Allen-Bradley ControlLogix, includes Remote Link Library feature
Not Reviewed
Halogen-Free
Status
Documents:
Drawing (PDF)
RoHS Certificate of Compliance (PDF)
Not Reviewed
Need more information on product
environmental compliance?
General
Product Family
Series
Network Interface
112073
CE, Class 1 Division 2
Ethernet: 10/100 Mbps, Serial: 2,400 to 115,200 bps
N/A
SST™
N/A
Email productcompliance@molex.com
For a multiple part number RoHS Certificate of
Compliance, click here
Approvals
Communication Speed
Mounting Style
Product Name
Protocol
Please visit the Contact Us section for any
non-product compliance questions.
Type
PLC Module
Physical
Channels
3
Search Parts in this Series
112073Series
Interface
Ethernet - Serial
Ethernet: RJ45, Serial: D-Sub Male (9 pin)
Carton
Freescale MCF5772
0°C to +60°C
Network Connection Type
Packaging Type
Processor
Temperature Range - Operating
Electrical
Current - Maximum Input
EMC
5.5W
EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN
61000-6-2
N/A
Supply Voltage
Material Info
Old Part Number
SST-ESR2-CLX-RLL
E-112073-0001
Reference - Drawing Numbers
Sales Drawing
This document was generated on 06/07/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
The BradCommunications™ SST communications module
connects your Rockwell Automation ControlLogix®
controller with up to 1 Ethernet Modbus TCP and 2 Serial
Modbus networks.
03 Apr. 08
DW2007211
1 Ethernet + 2 Serial Channels
For the Allen-Bradley® ControlLogix® Controller
Features
y
y
y
Save money!
1 Ethernet and 2 RS232/RS485
Serial Modbus channels on a
single slot - 1756 backplane
compatible
Save time!
No ladder logic to write for
configuration and data transfer
between module and
ControlLogix processor
Boot user configuration and
update firmware module through
integrated USB port
Overview
The BradCommunications™ SST™ Ethernet / Serial module connects Rockwell
Automation® ControlLogix® controllers to Modbus networks. Each module has 1
Ethernet and 2 Serial communication channels that act as independent Modbus
TCP Client/Server and Modbus Master or Slave protocols to exchange data with
other Modbus compatible devices.
y
y
Data format: Bit, Byte, Word,
Dword, Float
RLL feature : configure and
diagnose Modbus network
remotely via A-B RSLinx®
The SST module acts as a 1756 input/output module between the Modbus network
and the ControlLogix backplane. The data transfer from the SST™ module to the
ControlLogix processor supports 2 modes; a direct mode allowing mapping of
Modbus data in I/O processor image (496 inputs bytes / 496 output bytes) and a
messaging mode (based on CIP transaction) allowing access to Modbus data
images stored in 32K registers of the SST™ module’s memory.
y
y
y
Advanced Windows configuration
and diagnostics tools
Up to 8 SST™ modules can be
used in one ControlLogix rack
Support local and remote
chassis
The SST module has a USB port on the front panel which can be used for the
startup of the module when the user configuration is stored to a USB key. This can
also be beneficial if a breakdown occurs, allowing a very quick startup to occur with
a new SST module.
Protocols
y
y
Modbus TCP Client /Server
Modbus Serial Master or Slave
(RTU / ASCII)
Configuration and Diagnostics
Save your time, the SST module doesn’t require any ladder logic programming to
be used. The configuration is created using a PC-based Windows console software
connected via RLL (Remote Link Library) functionality allowing a remote access to
the SST module for the configuration and the diagnostics through Rockwell network
architectures (Ethernet/ControlNet/DeviceNet™).
Typical Applications
y
y
y
SCADA / supervisory
communication
Integration of legacy Modbus
devices
Bridge Rockwell networks to
Modbus compatible devices
The SST console allows the user to define the network parameters, Modbus
devices and the cyclic data exchanges. The console includes a user configuration
manager offering services for download, upload, copy, and rename of user
configurations. With this, a user can very easily and quickly create a new
configuration to initialize and start a SST module.
The SST console includes diagnostic tools to help with the commissioning and
monitoring of the Modbus connection. These tools allow access in read and write
modes to the Modbus slaves or to monitor and modify the module’s internal data
shared bound for a Modbus Master. Thus, the user-friendly tools are available for
controlling the communication in commissioning phase (PROG mode). This same
information is also available in production (RUN mode) through status words
making it possible for the user to manage the execution of the control application in
its ladder logic.
1 Ethernet + 2 Serial Channels
Diagnostic & Software Tools
Hardware Specifications
•
•
•
•
•
•
•
Allen-Bradley® 1756 ControlLogix®
Support multiple modules in a chassis
Local and remote rack
128 MB of onboard shared memory
8 MB of flash memory (user configuration and firmware)
4 characters display
Bus Interface
Memory
3 LEDs indicator:
Diagnostics
1 - health of the network (COMM)
2 - communication status (SYS)
3 - initialization complete and module is ok (OK)
Type A, USB 2 and 1.1 compatible
User configuration boot
•
•
•
USB Port (pending)
Module firmware upgrade
Current Consumption
Operating Temperature
Storage Temperature
850 mA @ 5V or 1.75 mA @ 24V
0ºC (32ºF) up to +60ºC (140ºF)
-40ºC (-40°F) up to +85ºC (185°F)
CE
Regulatory Approvals
Class 1 Div 2 (pending)
•
•
•
•
•
•
•
Maximum 496 bytes input data
Maximum 496 bytes output data
Maximum 250 words status data
Maximum 41 bytes configuration data
32K words and 32K bits
I/O Mapping
(for ControlLogix)
Shared Memory
(for ControlLogix)
Read/Write access
Ladder logic based on CIP messaging
- User Configuration Manager -
Windows-based software tools through A-B RSLinx™ and
Remote TCP
Configuration/Diagnostics
Network Specifications
Serial Communication Port
Ethernet Communication Port
Port: 1 distinct Ethernet port
Speed: 10/100 Mbps, auto-negotiation
Connector: BaseT (RJ45)
Protocol:
Port: 2 distinct Serial ports
Speed: 110 to 115200 bps
Parity: none, even, and odd
Data bits: 5, 6, 7, or 8
Stop bits: 1 or 2
Support client/server modes
simultaneously
Support TCP and UDP connection
Client mode
Up to 128 Modbus server devices
Support up to 4 simultaneous requests
Function code: 0, 1, 2, 3, 4, 15,16
Data format: Intel / Motorola
Server mode
Connector: RJ45 (DB9 male supplied cable)
Electrical interface: RS232, RS422 and
RS485, 500V galvanic insulation
Protocol:
Master
RTU or ASCII Mode
Maximum slave: 127 slaves devices
Function code: 0, 1, 2, 3, 4, 5, 6, 15, 16
Data format: Intel® / Motorola®
Slave
- Configuration Console -
32K words / 32K bits shared memory
Function Code: 0, 1, 3, 15, 16
RTU or ASCII Mode
32K words / 32K bits shared memory
Function Code: 0, 1, 3, 5, 6, 15, 16
Ordering Information
Part Number
Description
BradCommunications™ SST™ 1 Ethernet and 2 Serial ports PLC
communications module for Allen-Bradley ControlLogix, includes
Remote Link Library feature
SST-ESR2-CLX-RLL
- Modbus Read/Write Data Diagnostic Tool -
BradCommunications™ SST™ 4 Serial ports PLC communications
module for Allen-Bradley ControlLogix, includes Remote Link
Library feature
Also available:
SST-SR4-CLX-RLL
More Serial and Ethernet protocols available for Altus (AL2000 series), Alstom (Alspa C80-35 & C80-75), GE
Fanuc (GE90-30 & 90-70), Mitsubishi (AnA, AnU, AnS, QnA, QnAS), Omron (Sysmac C, CV and CS1), Schneider
(Premium, Micro, TSX/PMX), Siemens (S7-200/300/400, S5, TI-505). Please contact us for more information.
To contact us: www.woodhead.com
Reference Number: DW2007211 Date Published: January 2008
North America: US: + 1 800 225 7724 – Canada: +1 519 725 5136
Europe:
Asia:
France: +33 2 32 96 04 20 – Germany: +49 7252 94 96 0– Italy: +39 010 59 30 77 –
United: Kingdom +44 1495 356300
Shanghai, China: +86 21-5835-9885 - Tianjin, China: +86 22-23321717
Singapore: +65 6268-6868 – Yamato, Japan: +81 46-265-2428 – Nagoya, Japan: +81 52-221-5950
BradCommunications and SST are trademarks of Woodhead Industries.
© 2008 Molex Incorporated.
相关型号:
E-112078-0001
BradCommunications SST 4 Serial ports PLC communications module for Allen- Bradley ControlLogix
MOLEX
©2020 ICPDF网 联系我们和版权申明