E-112073-0001 [MOLEX]

BradCommunications SST 1 Ethernet and 2 Serial ports PLC communications module; BradCommunications SST 1个以太网和2个串行端口, PLC通信模块
E-112073-0001
型号: E-112073-0001
厂家: Molex    Molex
描述:

BradCommunications SST 1 Ethernet and 2 Serial ports PLC communications module
BradCommunications SST 1个以太网和2个串行端口, PLC通信模块

以太网 通信
文件: 总3页 (文件大小:2355K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
This document was generated on 06/07/2010  
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION  
Part Number:  
Status:  
1120730001  
Active  
EU RoHS  
ELV and RoHS  
Compliant  
REACH SVHC  
China RoHS  
Description:  
BradCommunications™ SST™ 1 Ethernet and 2 Serial ports PLC communications  
module for Allen-Bradley ControlLogix, includes Remote Link Library feature  
Not Reviewed  
Halogen-Free  
Status  
Documents:  
Drawing (PDF)  
RoHS Certificate of Compliance (PDF)  
Not Reviewed  
Need more information on product  
environmental compliance?  
General  
Product Family  
Series  
Network Interface  
112073  
CE, Class 1 Division 2  
Ethernet: 10/100 Mbps, Serial: 2,400 to 115,200 bps  
N/A  
SST™  
N/A  
Email productcompliance@molex.com  
For a multiple part number RoHS Certificate of  
Compliance, click here  
Approvals  
Communication Speed  
Mounting Style  
Product Name  
Protocol  
Please visit the Contact Us section for any  
non-product compliance questions.  
Type  
PLC Module  
Physical  
Channels  
3
Search Parts in this Series  
112073Series  
Interface  
Ethernet - Serial  
Ethernet: RJ45, Serial: D-Sub Male (9 pin)  
Carton  
Freescale MCF5772  
0°C to +60°C  
Network Connection Type  
Packaging Type  
Processor  
Temperature Range - Operating  
Electrical  
Current - Maximum Input  
EMC  
5.5W  
EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN  
61000-6-2  
N/A  
Supply Voltage  
Material Info  
Old Part Number  
SST-ESR2-CLX-RLL  
E-112073-0001  
Reference - Drawing Numbers  
Sales Drawing  
This document was generated on 06/07/2010  
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION  
The BradCommunicationsSST communications module  
connects your Rockwell Automation ControlLogix®  
controller with up to 1 Ethernet Modbus TCP and 2 Serial  
Modbus networks.  
03 Apr. 08  
DW2007211  
1 Ethernet + 2 Serial Channels  
For the Allen-Bradley® ControlLogix® Controller  
Features  
y
y
y
Save money!  
1 Ethernet and 2 RS232/RS485  
Serial Modbus channels on a  
single slot - 1756 backplane  
compatible  
Save time!  
No ladder logic to write for  
configuration and data transfer  
between module and  
ControlLogix processor  
Boot user configuration and  
update firmware module through  
integrated USB port  
Overview  
The BradCommunicationsSSTEthernet / Serial module connects Rockwell  
Automation® ControlLogix® controllers to Modbus networks. Each module has 1  
Ethernet and 2 Serial communication channels that act as independent Modbus  
TCP Client/Server and Modbus Master or Slave protocols to exchange data with  
other Modbus compatible devices.  
y
y
Data format: Bit, Byte, Word,  
Dword, Float  
RLL feature : configure and  
diagnose Modbus network  
remotely via A-B RSLinx®  
The SST module acts as a 1756 input/output module between the Modbus network  
and the ControlLogix backplane. The data transfer from the SSTmodule to the  
ControlLogix processor supports 2 modes; a direct mode allowing mapping of  
Modbus data in I/O processor image (496 inputs bytes / 496 output bytes) and a  
messaging mode (based on CIP transaction) allowing access to Modbus data  
images stored in 32K registers of the SSTmodule’s memory.  
y
y
y
Advanced Windows configuration  
and diagnostics tools  
Up to 8 SST™ modules can be  
used in one ControlLogix rack  
Support local and remote  
chassis  
The SST module has a USB port on the front panel which can be used for the  
startup of the module when the user configuration is stored to a USB key. This can  
also be beneficial if a breakdown occurs, allowing a very quick startup to occur with  
a new SST module.  
Protocols  
y
y
Modbus TCP Client /Server  
Modbus Serial Master or Slave  
(RTU / ASCII)  
Configuration and Diagnostics  
Save your time, the SST module doesn’t require any ladder logic programming to  
be used. The configuration is created using a PC-based Windows console software  
connected via RLL (Remote Link Library) functionality allowing a remote access to  
the SST module for the configuration and the diagnostics through Rockwell network  
architectures (Ethernet/ControlNet/DeviceNet).  
Typical Applications  
y
y
y
SCADA / supervisory  
communication  
Integration of legacy Modbus  
devices  
Bridge Rockwell networks to  
Modbus compatible devices  
The SST console allows the user to define the network parameters, Modbus  
devices and the cyclic data exchanges. The console includes a user configuration  
manager offering services for download, upload, copy, and rename of user  
configurations. With this, a user can very easily and quickly create a new  
configuration to initialize and start a SST module.  
The SST console includes diagnostic tools to help with the commissioning and  
monitoring of the Modbus connection. These tools allow access in read and write  
modes to the Modbus slaves or to monitor and modify the module’s internal data  
shared bound for a Modbus Master. Thus, the user-friendly tools are available for  
controlling the communication in commissioning phase (PROG mode). This same  
information is also available in production (RUN mode) through status words  
making it possible for the user to manage the execution of the control application in  
its ladder logic.  
1 Ethernet + 2 Serial Channels  
Diagnostic & Software Tools  
Hardware Specifications  
Allen-Bradley® 1756 ControlLogix®  
Support multiple modules in a chassis  
Local and remote rack  
128 MB of onboard shared memory  
8 MB of flash memory (user configuration and firmware)  
4 characters display  
Bus Interface  
Memory  
3 LEDs indicator:  
Diagnostics  
1 - health of the network (COMM)  
2 - communication status (SYS)  
3 - initialization complete and module is ok (OK)  
Type A, USB 2 and 1.1 compatible  
User configuration boot  
USB Port (pending)  
Module firmware upgrade  
Current Consumption  
Operating Temperature  
Storage Temperature  
850 mA @ 5V or 1.75 mA @ 24V  
0ºC (32ºF) up to +60ºC (140ºF)  
-40ºC (-40°F) up to +85ºC (185°F)  
CE  
Regulatory Approvals  
Class 1 Div 2 (pending)  
Maximum 496 bytes input data  
Maximum 496 bytes output data  
Maximum 250 words status data  
Maximum 41 bytes configuration data  
32K words and 32K bits  
I/O Mapping  
(for ControlLogix)  
Shared Memory  
(for ControlLogix)  
Read/Write access  
Ladder logic based on CIP messaging  
- User Configuration Manager -  
Windows-based software tools through A-B RSLinx™ and  
Remote TCP  
Configuration/Diagnostics  
Network Specifications  
Serial Communication Port  
Ethernet Communication Port  
Port: 1 distinct Ethernet port  
Speed: 10/100 Mbps, auto-negotiation  
Connector: BaseT (RJ45)  
Protocol:  
Port: 2 distinct Serial ports  
Speed: 110 to 115200 bps  
Parity: none, even, and odd  
Data bits: 5, 6, 7, or 8  
Stop bits: 1 or 2  
Support client/server modes  
simultaneously  
Support TCP and UDP connection  
Client mode  
Up to 128 Modbus server devices  
Support up to 4 simultaneous requests  
Function code: 0, 1, 2, 3, 4, 15,16  
Data format: Intel / Motorola  
Server mode  
Connector: RJ45 (DB9 male supplied cable)  
Electrical interface: RS232, RS422 and  
RS485, 500V galvanic insulation  
Protocol:  
Master  
RTU or ASCII Mode  
Maximum slave: 127 slaves devices  
Function code: 0, 1, 2, 3, 4, 5, 6, 15, 16  
Data format: Intel® / Motorola®  
Slave  
- Configuration Console -  
32K words / 32K bits shared memory  
Function Code: 0, 1, 3, 15, 16  
RTU or ASCII Mode  
32K words / 32K bits shared memory  
Function Code: 0, 1, 3, 5, 6, 15, 16  
Ordering Information  
Part Number  
Description  
BradCommunications™ SST™ 1 Ethernet and 2 Serial ports PLC  
communications module for Allen-Bradley ControlLogix, includes  
Remote Link Library feature  
SST-ESR2-CLX-RLL  
- Modbus Read/Write Data Diagnostic Tool -  
BradCommunications™ SST™ 4 Serial ports PLC communications  
module for Allen-Bradley ControlLogix, includes Remote Link  
Library feature  
Also available:  
SST-SR4-CLX-RLL  
More Serial and Ethernet protocols available for Altus (AL2000 series), Alstom (Alspa C80-35 & C80-75), GE  
Fanuc (GE90-30 & 90-70), Mitsubishi (AnA, AnU, AnS, QnA, QnAS), Omron (Sysmac C, CV and CS1), Schneider  
(Premium, Micro, TSX/PMX), Siemens (S7-200/300/400, S5, TI-505). Please contact us for more information.  
To contact us: www.woodhead.com  
Reference Number: DW2007211 Date Published: January 2008  
North America: US: + 1 800 225 7724 – Canada: +1 519 725 5136  
Europe:  
Asia:  
France: +33 2 32 96 04 20 – Germany: +49 7252 94 96 0– Italy: +39 010 59 30 77 –  
United: Kingdom +44 1495 356300  
Shanghai, China: +86 21-5835-9885 - Tianjin, China: +86 22-23321717  
Singapore: +65 6268-6868 – Yamato, Japan: +81 46-265-2428 – Nagoya, Japan: +81 52-221-5950  
BradCommunications and SST are trademarks of Woodhead Industries.  
© 2008 Molex Incorporated.  

相关型号:

E-112078-0001

BradCommunications SST 4 Serial ports PLC communications module for Allen- Bradley ControlLogix
MOLEX

E-1150

STANDARD TOLERANCE
ETC

E-1200

STANDARD TOLERANCE
ETC

E-1250

STANDARD TOLERANCE
ETC

E-127111-10-9

Label format - Old format order code cross reference
MACOM

E-1300

STANDARD TOLERANCE
ETC

E-1350

STANDARD TOLERANCE
ETC

E-1400

STANDARD TOLERANCE
ETC

E-145AK-4

E-145AK-4 SPST, 5 Amps, 115 VAC
TE

E-145Y

E-145Y 2PST, 60 Amps, 115/208 VAC
TE

E-145Z

E-145Z 2PST, 25 Amps, 120/208 VAC
TE

E-154064-10-9

Label format - Old format order code cross reference
TE