LWR3A00A18C300 概述
Interconnection Device 其他互连器件
LWR3A00A18C300 规格参数
生命周期: | Obsolete | Reach Compliance Code: | unknown |
风险等级: | 8.46 | 连接器类型: | INTERCONNECTION DEVICE |
Base Number Matches: | 1 |
LWR3A00A18C300 数据手册
通过下载LWR3A00A18C300数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Brad® Ultra-Lock®
(M12) EX
Connection System
for Zone 2
Hazardous
Locations
Achieve non-arcing connections in a one-step installation
process with the Brad® Ultra-Lock® (M12) EX Connection
System, designed for industrial automation use in Class I,
Division 2 and Zone 2 hazardous areas
Brad Ultra-Lock (M12) EX cordsets and receptacles provide process
automation installers a safe, quick connection interface for instrumentation
and control devices in potentially explosive and hazardous areas.
120614 Single Ended
Cordsets
The patented push-to-lock technology provides a simple and secure operator-
independent connection. Ultra-Lock connectors are designed to eliminate
connector-related intermittent signals in the harshest environments.
120613 Double Ended
Cordsets
120615 Receptacles
The Ultra-Lock (M12) EX connector has been designed with an integral
isolating ring that limits the access to the release mechanism of the
connector. The connector can be pushed on, but requires a screwdriver
to disconnect. With this characteristic, the connection point is considered
normally non-arcing and, therefore, suitable for use in a hazardous Class I,
Division 2 and Zone 2 classified areas.
Features and Benefits
Certified Class I, Division 2 and
Zone 2 cordsets and receptacles
Meets safety requirements for
hazardous usage areas
Brad® Ultra-Lock® (M12)
EX Connection System
for Zone 2 Hazardous
Locations
Integral isolating ring with access
notch design on cordset
Ensures a code-compliant
connection without additional
installation steps
Left: Female Single
Ended (Series 120614)
Pre-wired molded connections with
polarized positioning on cordset
Provides excellent performance
in high vibration applications;
provides fast installation
eliminating wiring termination
errors
Right: Male Single
Ended (Series 120614)
Push-to-lock connector design
Radial sealed
Provides a quick, secure and
reliable connection
Provides IP67 / IP68 / IP69K
watertight connection for
temporary submersion; consistent
operator-independent seal
Brad® Ultra-Lock®
(M12) EX
Specifications
Connection System
for Zone 2
Reference Information
FM File No.:
Electrical
Voltage (max.):
125V – 3 and 4 Pole
32V – 5 Pole
Current (max.): 4.0A
Contact Resistance: < 5mOhms
Hazardous
Certificate 3039279 (for US) and
3039279C (for Canada)
Class I, Division 2, Groups A, B,
C, D T6 when installed per
control drawing SD-120614-999
Class1, Zone 2, Aex nA IIC T6
when installed per control
CSA File No.:
Locations
Cables
Environmental
Protection: IP67 / IP68 / IP69K
Operating Temperature: -20 to +40°C
K05 – Yellow TPE jacket, 22 AWG PVC
conductors, 300V, UL PLTC-ER,
-40 to +105°C
Certificate 2251424 (for Canada)
Class I, Division 2, Groups A, B,
C, D
K03 – Yellow TPE jacket, 18 AWG PVC
conductors, 300V, UL PLTC-ER,
-40 to +105°C
C02 – Yellow thermostat rubber cable,
18 AWG EPDM conductor 300V,
SJOOW (UL) – SJOW (CSA),
-50 to +105°C
A18 – PVC insulated Conductors,
22 AWG, 300V, 19x#34 stranding,
UL 1061, 80°C
Physical
Isolating Ring: Stainless Steel 303
Coupling Nut: Nickel Plated Brass
O-ring: VITON
Contact Carrier: PUR
Connector Body: TPE
Contact:
Class I, Zone 2, IIC
Note: for FM and CSA Certificates see
product specification PS-120614-001
Copper Alloy with Gold over
Nickel plating
A16 – PVC insulated Conductors,
18 AWG, 300V, 19x#34 stranding,
UL 1061, 80°C
Additional Product Information
How it works -
Integral Isolating Ring
Access notch
Mate/Disconnect Sequence*
1. Align keyways and push-to-lock
connector to make connection
2. After mated connector is locked
in place, there is no possibility to
disconnect by hand
3. Insert #1 standard screwdriver
into access notch, twist-to-release
Ultra-Lock mechanism and pull at
the same time to disconnect
4. The connector is now disconnected
from the receptacle
Ultra-Lock
Receptacle
* WARNING – Explosion Hazard -
DO NOT CONNECT OR DISCONNECT
WHILE ENERGIZED
#1 Screwdriver required to
release latch or disconnect
1. Push-to-mate connector
2. Integral isolating ring does
not allow pull-to-disconnect
3. Insert tool, twist and pull
4. Disconnect
Brad® Ultra-Lock®
(M12) EX
Connection System
for Zone 2
Hazardous
Locations
Ordering Information
Single-Ended Cordsets, Female
Female Straight
Female 90°
Wire
Size
(AWG)
Current Voltage
Cable
Type
Cable Jacket
(Cable Code)
Length
(m)
Pole
*Certifications
(max.)
(max.)
Eng. No.
Order No.
Eng. No.
Order No.
PLTC-ER
SJOOW
TPE (K05)
RUBBER (C02)
TPE (K05)
22
18
22
(1)
LW03000K05M020
LW03000C02M020
LW04000K05M020
LW04000K03M020
LW04000C02M020
LW05000K03M020
120614-0001
120614-4001
120614-0005
120614-2001
120614-4002
120614-2002
LW03001K05M020
LW03001C02M020
LW04001K05M020
LW04001K03M020
LW04001C02M020
LW05001K03M020
120614-0007
120614-4005
120614-0008
120614-2005
120614-4006
120614-2006
3
(1), (2)
125
32
4.0A
PLTC-ER
2
(1)
4
5
TPE (K03)
SJOOW
RUBBER (C02)
TPE (K03)
18
(1), (2)
(1)
PLTC-ER
Single-Ended Cordsets, Male
Male Straight
Male 90°
Wire
Size
(AWG)
Current Voltage
Cable
Type
Cable Jacket
(Cable Code)
Length
(m)
Pole
*Certifications
(max.)
(max.)
Eng. No.
Order No.
Eng. No.
Order No.
PLTC-ER
SJOOW
TPE (K05)
RUBBER (C02)
TPE (K05)
22
18
22
(1)
LW03006K05M020
LW03006C02M020
LW04006K05M020
LW04006K03M020
LW04006C02M020
LW05006K03M020
120614-0003
120614-4003
120614-0006
120614-2003
120614-4004
120614-2004
LW03007K05M020
LW03007C02M020
LW04007K05M020
LW04007K03M020
LW04007C02M020
LW05007K03M020
120614-0009
120614-4007
120614-0010
120614-2007
120614-4008
120614-2008
3
(1), (2)
125
32
4.0A
PLTC-ER
2
(1)
4
5
TPE (K03)
SJOOW
RUBBER (C02)
TPE (K03)
18
(1), (2)
(1)
PLTC-ER
Double-Ended Cordsets
Female Straight to Male Straight
Female 90° to Male Straight
Wire
Size
(AWG)
Current Voltage
Cable
Type
Cable Jacket
(Cable Code)
Length
(m)
Pole
*Certifications
(max.)
(max.)
Eng. No.
Order No.
Eng. No.
Order No.
PLTC-ER
SJOOW
TPE (K05)
RUBBER (C02)
TPE (K05)
22
18
22
(1)
LWLW3030K05M010
LWLW3030C02M010
LWLW4030K05M010
LWLW4030K03M010
LWLW4030C02M010
LWLW5030K03M010
120613-0001
120613-4001
120613-0002
120613-2001
120613-4002
120613-2002
LWLW3031K05M010
LWLW3031C02M010
LWLW4031K05M010
LWLW4031K03M010
LWLW4031C02M010
LWLW5031K03M010
120613-0005
120613-4005
120613-0006
120613-2005
120613-4006
120613-2006
3
(1), (2)
125
32
4.0A
PLTC-ER
2
(1)
4
5
TPE (K03)
SJOOW
RUBBER (C02)
TPE (K03)
18
(1), (2)
(1)
PLTC-ER
Female Straight to Male 90°
Female 90° to Male 90°
Wire
Size
(AWG)
Current Voltage
Cable
Type
Cable Jacket
(Cable Code)
Length
(m)
Pole
*Certifications
(max.)
(max.)
Eng. No.
Order No.
Eng. No.
Order No.
PLTC-ER
SJOOW
TPE (K05)
RUBBER (C02)
TPE (K05)
22
18
22
(1)
LWLW3032K05M010
LWLW3032C02M010
LWLW4032K05M010
LWLW4032K03M010
LWLW4032C02M010
LWLW5032K03M010
120613-0003
120613-4003
120613-0004
120613-2003
120613-4004
120613-2004
LWLW3033K05M010
LWLW3033C02M010
LWLW4033K05M010
LWLW4033K03M010
LWLW4033C02M010
LWLW5033K03M010
120613-0007
120613-4007
120613-0008
120613-2007
120613-4008
120613-2008
3
(1), (2)
125
32
4.0A
PLTC-ER
2
(1)
4
5
TPE (K03)
SJOOW
RUBBER (C02)
TPE (K03)
18
(1), (2)
(1)
PLTC-ER
* (1) Certified for US installations (2) Certified for Canadian installations
Brad® Ultra-Lock®
(M12) EX
Connection System
for Zone 2
Hazardous
Locations
Ordering Information
Female Receptacles
½” - 14NPT Front Panel Mount
¼” - 18NPT Front Panel Mount
Current Voltage
Wire
Type
Wire Size
(AWG)
Length
(m)
Pole
(max.)
(max.)
Eng. No.
Order No.
Eng. No.
Order No.
3
4
5
LWR3000A18C300
LWR4000A18C300
LWR5000A18C300
120615-0001
120615-0002
120615-0003
LWR3A00A18C300
LWR4A00A18C300
LWR5A00A18C300
120615-0004
120615-0005
120615-0006
PVC
UL1061
(A18)
125
32
4.0A
22
0.305
Male Receptacles
½” - 14NPT Front Panel Mount
¼” - 18NPT Front Panel Mount
Current Voltage
Pole
Wire
Type
Wire Size
(AWG)
Length
(m)
(max.)
(max.)
Eng. No.
Order No.
Eng. No.
Order No.
3
4
5
LWR3006A18C300
LWR4006A18C300
LWR5006A18C300
120615-1001
120615-1002
120615-1003
LWR3A06A18C300
LWR4A06A18C300
LWR5A06A18C300
120615-1004
120615-1005
120615-1006
PVC
UL1061
(A18)
125
32
4.0A
22
0.305
Applications
Field Instrumentation and Control
Devices in Class I, Division 2 and
Zone 2 Hazardous areas:
– Oil and Gas Production and
Transportation Facilities
– Oil Refineries
– Petrochemical Complexes
– Waste Water Processing Plants
– Pharmaceutical Manufacturing
– Food and Beverage Processing
www.molex.com/link/bradultralockex.html
Order No. 987650-6781 Rev. 2
Printed in USA/KC/2012.08
©2012 Molex
LWR3A00A18C300 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
LWR4000A18C300 | MOLEX | Interconnection Device | 获取价格 | |
LWR5A06A18C300 | MOLEX | Interconnection Device | 获取价格 | |
LWR98A | INFINEON | Visible LED, Diffused | 获取价格 | |
LWS-0505E | POWER-SYSTEMS | DC-DC Converter UNIT 5 W WIDE INPUT RANGE DC-DC CONVERTER | 获取价格 | |
LWS-0512E | POWER-SYSTEMS | DC-DC Converter UNIT 5 W WIDE INPUT RANGE DC-DC CONVERTER | 获取价格 | |
LWS-0515E | POWER-SYSTEMS | DC-DC Converter UNIT 5 W WIDE INPUT RANGE DC-DC CONVERTER | 获取价格 | |
LWS-1203.3E | POWER-SYSTEMS | DC-DC Converter UNIT 5 W WIDE INPUT RANGE DC-DC CONVERTER | 获取价格 | |
LWS-1203.3T | POWER-SYSTEMS | DC-DC Converter UNIT 5 W WIDE INPUT RANGE DC-DC CONVERTER | 获取价格 | |
LWS-1205E | POWER-SYSTEMS | DC-DC Converter UNIT 5 W WIDE INPUT RANGE DC-DC CONVERTER | 获取价格 | |
LWS-1205T | POWER-SYSTEMS | DC-DC Converter UNIT 5 W WIDE INPUT RANGE DC-DC CONVERTER | 获取价格 |
LWR3A00A18C300 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6