IE2405KS-1W [MORNSUN]
DUAL OUTPUT DC-DC CONVERTER; 双输出DC- DC转换器型号: | IE2405KS-1W |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | DUAL OUTPUT DC-DC CONVERTER |
文件: | 总2页 (文件大小:166K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
IE_KS-1W & IE_S-1W Series
1W FIXED INPUT ISOLATED & REGULATED
DUAL OUTPUT DC-DC CONVERTER
multi-country patent protection RoHS
FEATURES
PRODUCT PROGRAM
Low ripple and good EMC features
Good dynamic feature
3KVDC Isolation
Input
Output
Switching
frequency
(KHz,Typ.)
Part
Number
Efficiency
(%, Typ)
Voltage (VDC)
Nominal Range
Current (mA)
Voltage
(VDC)
Max
±100
±100
±56
Min
±10
±10
±6
SIP Package
IE0505S-1W
±5
69
54
61
62
64
72
54
61
63
64
72
54
60
63
64
83
83
Temperature Range: -40°C to +85°C
Internal SMD construction
No Heat sink Required
No External Component Required
RoHS Compliance
IE0505KS-1W*
IE0509KS-1W*
IE0512KS-1W
IE0515KS-1W
IE1205S-1W
±5
5
4.75-5.25
11.4-12.6
22.8-25.2
±9
83
±12
±15
±5
±42
±5
83
±33
±4
250
100
83
±100
±100
±56
±10
±10
±6
IE1205KS-1W*
IE1209KS-1W*
IE1212KS-1W*
IE1215KS-1W*
IE2405S-1W
±5
12
24
±9
83
APPLICATIONS
±12
±15
±5
±42
±5
83
The IE_KS-1W&IE_S-1W Series are
specially designed for applications where a
group of polar power supplies are isolated
from the input power supply in a distributed
power supply system on a circuit board.
These products apply to:
±33
±4
83
±100
±100
±56
±10
±10
±6
83
IE2405KS-1W
IE2409KS-1W*
IE2412KS-1W
IE2415KS-1W
±5
83
±9
83
±12
±15
±42
±5
83
1) Where the voltage of the input power
supply is fixed (voltage variation ≤±5%);
2) Where isolation is necessary between
input and output (isolation voltage
≤3000VDC);
±33
±4
300
* Designing.
3) Where the regulation of the output
voltage and the output ripple noise are
demanded.
ISOLATION SPECIFICATIONS
Item
Test conditions
Min
Typ
Typ
Max Units
VDC
Isolation voltage
Isolation resistance
Tested for 1 minute and 1 mA max 3000
Test at 500VDC
1000
MΩ
MODEL SELECTION
IE0505KS-1W
OUTPUT SPECIFICATIONS
Item
Test conditions
Min
0.1
Max
1
Units
W
Rated Power
Package Style
Output Voltage
Output power
Line regulation
Load regulation
For Vin change of ±5%
±0.25
±1
Input Voltage
Product Series
%
10% to 100% full load
Output voltage accuracy 100% full load
±3
Temperature drift
Output ripple*
Output noise*
100% full load
0.03
20
%/°C
20MHz Bandwidth
20MHz Bandwidth
10
50
mVp-p
100
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Hangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
Fax: 86-20-38601272
http://www.mornsun-power.com
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at testing of Power
Converter section, application notes.
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
2. See below recommended circuits for more details.
MORNSUN reserves the copyright
Specifications subject to change without notice
IE_KS-1W & IE_S-1W
A/2-2008
Page 1 of 2
COMMON SPECIFICATIONS
Filtering
To get an extreme low ripple, an “LC”
Item
Test conditions
Min
Typ
20
Max
95
Units
%
filtering network may be connected to the
input and output ends of the DC/DC
Storage humidity
Operating temp. range
Storage temp. range
Temp. rise at full load
Lead temperature
Cooling
-40
-55
85
converter, which may produce
a
more
125
30
significant filtering effect. It should also be
noted that the inductance and the frequency
of the “LC” filtering network should be
staggered with the DC/DC frequency to avoid
mutual interference see (figure 1).
°C
1.5mm from case for 10 seconds
300
Free air convection
Plastic (UL94-V0)
Continuous
1
Case material
IEXXXXS-1W
L
Short circuit protection
L
+Vo
IEXXXXKS-1W *
s
Vin
Cout
Cin
0V
DC
DC
MTBF
3500
K hours
g
L
Cout
GND
-Vo
Weight
5.2
(Figure 1)
*Supply voltage must be discontinued at the end of short circuit duration.
In some circuits which are sensitive to noise
and ripple, a filtering capacitor may be added
to the DC/DC output end and input end to
reduce the noise and ripple. However, the
capacitance of the output filter capacitor must
proper. If the capacitance is too big, a startup
problem might arise. For every channel of
output, providing the safe and reliable
TYPICAL CHARACTERISTICS
Temperature Derating Graph
operation
is
ensured,
the
greatest
capacitance of its filter capacitor refer to the
external capacitor table (table1).
EXTERNAL CAPACITOR TABLE (TABLE1)
Operating Temp.( C)
Vin
(VDC)
Vout
(VDC)
Cout
(uF)
Cin
(uF)
OUTLINE DIMENSIONS
5
4.7
2.2
1
±5
±9
4.7
2.2
1
First Angle Projection
12
24
--
±12
±15
(Bottom View)
7
RECOMMENDED FOOTPRINT
Top view,grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
1 2
9 10
--
0.47
2.32
2.54
Overload Protection
Under normal operating conditions, the
output circuit of these products has no
protection against over-current. The simplest
method is to connect a self-recovery fuse in
series at the input end or add a circuit breaker
to the circuit.
2
1
7
9
10
(1.080)
FOOTPRINT DETAILS
(Side View)
When the environment temperature is
higher than 71°C, the product output
power should be less then 60% of the
rated power.
Function
Pin
1
Vin
GND
+Vo
-Vo
0.50
(0.020)
2
7
Note:
Unit:mm(inch)
Pin section:0.50*0.30mm(0.020*0.012inch)
Pin section tolerances: 0.10mm( 0.004inch)
General tolerances: 0.25mm( 0.010inch)
No parallel connection or plug and play.
9
Use dual output simultaneously, forbid
opening output pin(0V) to use as single
output.
0V
10
APPLICATION NOTE
Requirement on output load
To ensure this module can operate efficiently and reliably, a minimum load is specified for
this kind of DC/DC converter in addition to a maximum load (namely full load). During
operation, make sure the specified range of input voltage is not exceeded, the minimum
output load is not less than 10% of the full load, that this product should never be
operated under no load!
MORNSUN reserves the copyright
Specifications subject to change without notice
IE_KS-1W & IE_S-1W
A/2-2008
Page 2 of 2
相关型号:
©2020 ICPDF网 联系我们和版权申明