IE2405KS-1W [MORNSUN]

DUAL OUTPUT DC-DC CONVERTER; 双输出DC- DC转换器
IE2405KS-1W
型号: IE2405KS-1W
厂家: MORNSUN SCIENCE& TECHNOLOGY LTD.    MORNSUN SCIENCE& TECHNOLOGY LTD.
描述:

DUAL OUTPUT DC-DC CONVERTER
双输出DC- DC转换器

转换器 输出元件 DC-DC转换器
文件: 总2页 (文件大小:166K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
IE_KS-1W & IE_S-1W Series  
1W FIXED INPUT ISOLATED & REGULATED  
DUAL OUTPUT DC-DC CONVERTER  
multi-country patent protection RoHS  
FEATURES  
PRODUCT PROGRAM  
Low ripple and good EMC features  
Good dynamic feature  
3KVDC Isolation  
Input  
Output  
Switching  
frequency  
(KHz,Typ.)  
Part  
Number  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Nominal Range  
Current (mA)  
Voltage  
(VDC)  
Max  
±100  
±100  
±56  
Min  
±10  
±10  
±6  
SIP Package  
IE0505S-1W  
±5  
69  
54  
61  
62  
64  
72  
54  
61  
63  
64  
72  
54  
60  
63  
64  
83  
83  
Temperature Range: -40°C to +85°C  
Internal SMD construction  
No Heat sink Required  
No External Component Required  
RoHS Compliance  
IE0505KS-1W*  
IE0509KS-1W*  
IE0512KS-1W  
IE0515KS-1W  
IE1205S-1W  
±5  
5
4.75-5.25  
11.4-12.6  
22.8-25.2  
±9  
83  
±12  
±15  
±5  
±42  
±5  
83  
±33  
±4  
250  
100  
83  
±100  
±100  
±56  
±10  
±10  
±6  
IE1205KS-1W*  
IE1209KS-1W*  
IE1212KS-1W*  
IE1215KS-1W*  
IE2405S-1W  
±5  
12  
24  
±9  
83  
APPLICATIONS  
±12  
±15  
±5  
±42  
±5  
83  
The IE_KS-1W&IE_S-1W Series are  
specially designed for applications where a  
group of polar power supplies are isolated  
from the input power supply in a distributed  
power supply system on a circuit board.  
These products apply to:  
±33  
±4  
83  
±100  
±100  
±56  
±10  
±10  
±6  
83  
IE2405KS-1W  
IE2409KS-1W*  
IE2412KS-1W  
IE2415KS-1W  
±5  
83  
±9  
83  
±12  
±15  
±42  
±5  
83  
1) Where the voltage of the input power  
supply is fixed (voltage variation ≤±5%);  
2) Where isolation is necessary between  
input and output (isolation voltage  
3000VDC);  
±33  
±4  
300  
* Designing.  
3) Where the regulation of the output  
voltage and the output ripple noise are  
demanded.  
ISOLATION SPECIFICATIONS  
Item  
Test conditions  
Min  
Typ  
Typ  
Max Units  
VDC  
Isolation voltage  
Isolation resistance  
Tested for 1 minute and 1 mA max 3000  
Test at 500VDC  
1000  
MΩ  
MODEL SELECTION  
IE0505KS-1W  
OUTPUT SPECIFICATIONS  
Item  
Test conditions  
Min  
0.1  
Max  
1
Units  
W
Rated Power  
Package Style  
Output Voltage  
Output power  
Line regulation  
Load regulation  
For Vin change of ±5%  
±0.25  
±1  
Input Voltage  
Product Series  
%
10% to 100% full load  
Output voltage accuracy 100% full load  
±3  
Temperature drift  
Output ripple*  
Output noise*  
100% full load  
0.03  
20  
%/°C  
20MHz Bandwidth  
20MHz Bandwidth  
10  
50  
mVp-p  
100  
MORNSUN Science & Technology co.,Ltd.  
Address: 2th floor 6th building, Hangzhou  
Industrial District, Guangzhou, China  
Tel: 86-20-38601850  
Fax: 86-20-38601272  
http://www.mornsun-power.com  
*Test ripple and noise by parallel cablemethod. See detailed operation instructions at testing of Power  
Converter section, application notes.  
Note:  
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load  
unless otherwise specified.  
2. See below recommended circuits for more details.  
MORNSUN reserves the copyright  
Specifications subject to change without notice  
IE_KS-1W & IE_S-1W  
A/2-2008  
Page 1 of 2  
COMMON SPECIFICATIONS  
Filtering  
To get an extreme low ripple, an LC”  
Item  
Test conditions  
Min  
Typ  
20  
Max  
95  
Units  
%
filtering network may be connected to the  
input and output ends of the DC/DC  
Storage humidity  
Operating temp. range  
Storage temp. range  
Temp. rise at full load  
Lead temperature  
Cooling  
-40  
-55  
85  
converter, which may produce  
a
more  
125  
30  
significant filtering effect. It should also be  
noted that the inductance and the frequency  
of the LCfiltering network should be  
staggered with the DC/DC frequency to avoid  
mutual interference see (figure 1).  
°C  
1.5mm from case for 10 seconds  
300  
Free air convection  
Plastic (UL94-V0)  
Continuous  
1
Case material  
IEXXXXS-1W  
L
Short circuit protection  
L
+Vo  
IEXXXXKS-1W *  
s
Vin  
Cout  
Cin  
0V  
DC  
DC  
MTBF  
3500  
K hours  
g
L
Cout  
GND  
-Vo  
Weight  
5.2  
(Figure 1)  
*Supply voltage must be discontinued at the end of short circuit duration.  
In some circuits which are sensitive to noise  
and ripple, a filtering capacitor may be added  
to the DC/DC output end and input end to  
reduce the noise and ripple. However, the  
capacitance of the output filter capacitor must  
proper. If the capacitance is too big, a startup  
problem might arise. For every channel of  
output, providing the safe and reliable  
TYPICAL CHARACTERISTICS  
Temperature Derating Graph  
operation  
is  
ensured,  
the  
greatest  
capacitance of its filter capacitor refer to the  
external capacitor table (table1).  
EXTERNAL CAPACITOR TABLE (TABLE1)  
Operating Temp.( C)  
Vin  
(VDC)  
Vout  
(VDC)  
Cout  
(uF)  
Cin  
(uF)  
OUTLINE DIMENSIONS  
5
4.7  
2.2  
1
±5  
±9  
4.7  
2.2  
1
First Angle Projection  
12  
24  
--  
±12  
±15  
(Bottom View)  
7
RECOMMENDED FOOTPRINT  
Top view,grid:2.54mm(0.1inch)  
diameter:1.00mm(0.039inch)  
1 2  
9 10  
--  
0.47  
2.32  
2.54  
Overload Protection  
Under normal operating conditions, the  
output circuit of these products has no  
protection against over-current. The simplest  
method is to connect a self-recovery fuse in  
series at the input end or add a circuit breaker  
to the circuit.  
2
1
7
9
10  
(1.080)  
FOOTPRINT DETAILS  
(Side View)  
When the environment temperature is  
higher than 71°C, the product output  
power should be less then 60% of the  
rated power.  
Function  
Pin  
1
Vin  
GND  
+Vo  
-Vo  
0.50  
(0.020)  
2
7
Note:  
Unit:mm(inch)  
Pin section:0.50*0.30mm(0.020*0.012inch)  
Pin section tolerances: 0.10mm( 0.004inch)  
General tolerances: 0.25mm( 0.010inch)  
No parallel connection or plug and play.  
9
Use dual output simultaneously, forbid  
opening output pin(0V) to use as single  
output.  
0V  
10  
APPLICATION NOTE  
Requirement on output load  
To ensure this module can operate efficiently and reliably, a minimum load is specified for  
this kind of DC/DC converter in addition to a maximum load (namely full load). During  
operation, make sure the specified range of input voltage is not exceeded, the minimum  
output load is not less than 10% of the full load, that this product should never be  
operated under no load!  
MORNSUN reserves the copyright  
Specifications subject to change without notice  
IE_KS-1W & IE_S-1W  
A/2-2008  
Page 2 of 2  

相关型号:

IE2405S

DC-DC Power Supplies
XPPOWER

IE2405S-1W

DUAL OUTPUT DC-DC CONVERTER
MORNSUN

IE2405S-H

DC-DC Regulated Power Supply Module, 1 Output, 1W, Hybrid, SIP-4
XPPOWER

IE2405SH

Analog IC
ETC

IE2405XS-1W

FIXED INPUT,ISOLATED®ULATED Dual Output DC/DC Converter
MICRODC

IE2405XS-2W

FIXED INPUT,ISOLATED®ULATED Dual Output DC/DC Converter
MICRODC

IE2409

DC/DC Converters
ETC

IE2409D

Analog IC
ETC

IE2409D-H

暂无描述
XPPOWER

IE2409DH

Analog IC
ETC

IE2409H

DC/DC Converters
ETC

IE2409KS-1W

DUAL OUTPUT DC-DC CONVERTER
MORNSUN