LH40-13B24 [MORNSUN]

40W, AC/DC converter;
LH40-13B24
型号: LH40-13B24
厂家: MORNSUN SCIENCE& TECHNOLOGY LTD.    MORNSUN SCIENCE& TECHNOLOGY LTD.
描述:

40W, AC/DC converter

文件: 总5页 (文件大小:917K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AC/DC Converter  
LH40-13Bxx series  
40W, AC/DC converter  
FEATURES  
Input voltage range: 85 - 305VAC/100 - 430VDC  
AC and DC dual-use(input from the same terminal)  
High efficiency up to 84%  
Isolation voltage: 3K VAC  
Operating temperature range: -40to +85℃  
Output short circuit, over-current, over-voltage protection  
RoHS  
LH40-13Bxx series are 40W efficient environmental-protection AC-DC module power supply, which have advantages such as universal input  
voltage, accept either AC or DC input, high efficiency, high reliability, low power consumption and high safety isolation. They offer good  
EMC performance, meet IEC/EN61000-4, CISPR32/EN55032, UL62368 and EN62368 standards. The series products are widely used in  
industries such as industrial control, electricity, office.  
Note: Please refer to Design Reference when module being used in a bad EMC environment.  
Selection Guide  
Nominal Output Voltage and  
Current(Vo/Io)  
Efficiency  
(277VAC, %/Typ.)  
Max. Capacitive  
Load(µF)  
Part No.  
Output Power  
40W  
LH40-13B12  
LH40-13B24  
12VDC/3333mA  
24VDC/1667mA  
84  
84  
9000  
2000  
Input Specifications  
Item  
Operating Conditions  
AC input  
Min.  
85  
100  
47  
--  
Typ.  
--  
Max.  
305  
430  
63  
Unit  
VAC  
VDC  
Hz  
Input Voltage Range  
Input frequency  
Input current  
--  
DC input  
--  
115VAC  
277VAC  
115VAC  
277VAC  
--  
1.0  
0.5  
--  
--  
--  
A
--  
30  
70  
Inrush current  
Hot Plug  
--  
--  
Unavailable  
Output Specifications  
Item  
Operating Conditions  
Min.  
--  
Typ.  
±2  
Max.  
--  
Unit  
%
Output Voltage Accuracy  
Line Regulation  
Full load  
--  
±0.5  
±1  
--  
%
Load Regulation  
0% - 100% load  
--  
--  
Ripple & Noise*  
--  
50  
100  
--  
mV  
20MHz bandwidth (peak-peak value)  
--  
±0.02  
--  
%/  
Temperature Coefficient  
Stand-by Power Consumption  
Short Circuit Protection  
--  
0.8  
W
Continuous, self-recovery  
110%Io self-recovery  
16VDC  
Over-current Protection  
12V  
24V  
Over-voltage Protection  
35VDC  
Min. Load  
Trim  
0
--  
--  
--  
--  
--  
--  
±10  
--  
%
15  
60  
115VAC input  
277VAC input  
Hold-up Time  
ms  
--  
Note: * Ripple and noise are measured by “parallel cable” method, please see AC-DC Converter Application Notes for specific operation.  
2018.06.30-A/0  
Page 1 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
AC/DC Converter  
LH40-13Bxx series  
General Specifications  
Item  
Operating Conditions  
Min.  
3000  
-40  
-40  
--  
Typ.  
--  
Max.  
--  
Unit  
Test time: 1min (leakage current5mA)  
Isolation Voltage  
Input-output  
VAC  
--  
+85  
+85  
95  
Operating Temperature  
Storage Temperature  
Storage Humidity  
--  
--  
%RH  
Wave-soldering  
Manual-welding  
260 ± 5; time: 5 - 10s  
360 ± 10; time: 3 - 5s  
Welding Temperature  
Switching Frequency  
--  
65  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
--  
kHz  
-40to -30(LH40-13B12)  
+55to +70(LH40-13B12)  
+70to +85(LH40-13B12)  
-40to -30(LH40-13B24)  
+55to +70(LH40-13B24)  
+70to +85(LH40-13B24)  
85-100VAC  
3.0  
3.67  
1.67  
2.0  
%/℃  
Power Derating  
Safety Standard  
2.7  
2.33  
1.33  
0.72  
%/VAC  
277-305VAC  
IEC62368/EN62368/UL62368  
CLASS II  
Safety Class  
MTBF  
MIL-HDBK-217F@25300,000 h  
Physical Specifications  
Casing Material  
Dimensions  
Black flame-retardant and heat-resistant plastic (UL94V-0)  
89.00*63.50*25.00 mm  
225g (Typ.)  
Weight  
Cooling Method  
Free air convection  
EMC Specifications  
CE  
CISPR32/EN55032 CLASS B  
EMI  
RE  
CISPR32/EN55032 CLASS B  
IEC/EN61000-4-2 Contact ±6KV/Air ±8KV  
IEC/EN61000-4-3 10V/m  
Perf. Criteria B  
perf. Criteria A  
perf. Criteria B  
perf. Criteria B  
perf. Criteria B  
ESD  
RS  
IEC/EN61000-4-4 ±2KV  
EFT  
IEC/EN61000-4-4 ±4KV (See Fig. 2 for recommended circuit)  
IEC/EN61000-4-5 line to line ±1KV  
EMS  
Surge  
CS  
IEC/EN61000-4-5 line to line±2KV/ line to ground ±4KV  
(See Fig. 2 for recommended circuit)  
perf. Criteria B  
perf. Criteria A  
IEC/EN61000-4-6 10Vr.m.s  
Product Characteristic Curve  
Note:  
Input voltage should be derated based on temperature derating when it is 85-100VAC/277-305VAC/100-120VDC/400-430VDC;  
This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE.  
2018.06.30-A/0  
Page 2 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
AC/DC Converter  
LH40-13Bxx series  
Design Reference  
1. Typical application circuit  
NTC  
FUSE  
MOV  
RL  
C1 C2 TVS1  
AC(L)  
+Vo  
AC(L)  
AC-DC  
AC(N)  
AC(N)  
-Vo  
Fig. 1  
Model  
FUSE  
MOV  
S10K350  
NTC  
C1(µF)  
1
C2(µF)  
220  
TVS1  
LH40-13B12  
LH40-13B24  
SMBJ20A  
SMBJ30A  
3.15A/300VAC, slow  
fusing, necessary  
5D-9  
120  
Note: Output filtering capacitor C2 is electrolytic capacitors, it is recommended to apply electrolytic capacitor with high frequency and low resistance. For  
capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitor voltage reduced to at least 80%. C1 is ceramic capacitors, which is  
used to filter high-frequency noise. TVS is a recommended component to protect post-circuits if converter fails.  
2. EMC solution-recommended circuit  
NTC  
MOV2  
MOV3  
FUSE  
C1  
C2  
TVS  
RL  
AC(L)  
AC(L)  
+Vo  
CY1  
CY2  
R1  
+
CX  
AC/DC  
LCM  
MOV1  
-Vo  
AC(N)  
AC(N)  
Fig.2 (Output external circuit refer to the typical application circuit)  
Element model  
Recommended value  
S14K350  
MOV1  
MOV2, MOV3  
CX  
S07K350  
0.15µF/300VAC  
2.2nF/400VAC  
2.2nF /400VAC  
1MΩ/2W  
CY1  
CY2  
R1  
LCM  
NTC  
2.2mH, recommended to use MORNSUN’s FL2D-10-222;  
5D-14  
FUSE  
3.15A/300V, slow fusing, necessary  
2018.06.30-A/0  
Page 3 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
AC/DC Converter  
LH40-13Bxx series  
3. Application of Trim and calculation of Trim resistance  
+Vot  
+Vot  
R1  
RT  
R1  
R3  
Vref  
Trim  
R3  
Vref  
R2  
Trim  
R2  
RT  
0V  
Trim down  
0V  
Trim up  
Applied circuits of Trim (Part in broken line is the interior of models)  
Calculation formula of Trim resistance:  
aR2  
R2-a  
Vref  
Vot-Vref  
-R3  
up:  
RT=  
a=  
R1  
RT is Trim resistance, a is a self-defined  
parameter, with no real meaning.  
aR1  
R1-a  
Vot-Vref  
Vref  
down:  
-R3  
RT=  
a=  
R2  
Vout  
12V  
R1(KΩ)  
R2(KΩ)  
R3(KΩ)  
Vref(V)  
Vot(V)  
3.83  
1
1
2.5  
Output voltage  
after regulation,  
variation ±10%  
24V  
8.66  
1
1
2.5  
4. For more information, Please find the application note on www.mornsun-power.com  
Dimensions and Recommended Layout  
2018.06.30-A/0  
Page 4 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
AC/DC Converter  
LH40-13Bxx series  
Notes:  
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing  
bag number: 58220021;  
2. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75% with nominal  
input voltage and rated output load;  
3. All index testing methods in this datasheet are based on our Company’s corporate standards;  
4. We can provide product customization service, please contact our technicians directly for specific information;  
5. Products are related to laws and regulations: see "Features" and "EMC";  
6. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by  
qualified units.  
Mornsun Guangzhou Science & Technology Co., Ltd.  
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China  
Tel: 86-20-38601850-8801  
Fax: 86-20-38601272  
E-mail: info@mornsun.cn  
2018.06.30-A/0  
Page 5 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  

相关型号:

LH4001

Wideband Current Buffer
NSC

LH4001CN

Wideband Current Buffer
NSC

LH4002

Wideband Video Buffer
CALOGIC

LH4002A

Wideband Video Buffer
CALOGIC

LH4002AH

Wideband Video Buffer
CALOGIC

LH4002AH

Buffer Amplifier, 1 Func, Hybrid, MBCY8,
SIPEX

LH4002AN

Wideband Video Buffer
CALOGIC

LH4002C

Wideband Video Buffer
CALOGIC

LH4002CH

Wideband Video Buffer
CALOGIC

LH4002CH

Buffer Amplifier, 1 Func, Hybrid, MBCY8,
SIPEX

LH4002CN

Wideband Video Buffer
CALOGIC

LH4002CN-8

BUFFER AMPLIFIER, PDIP8, PLASTIC, DIP-8
TI