Active Single channel Analog signal
Isolation barrier (Iin & Iout)
T11/12/21/22_B
APPLICATIONS
PRODUCT PROGRAM
Analog signal isolating barrier, is
a signal
Part
Number
Isolation
Power Output
Power Supply
Input
Output
Channels
conditioner with electrical insulation between
input and output, which can receive the standard
or non-standard analog signal input from the
scene, and transmit a standard output signal to
the control room or DCS, to get three-port
isolated among power supply, input and output. It
is designed for translating signals of apparatus in
hazardous area, isolating and transforming these
signals into standard signals which can be
accepted by industry computer, DCS, PLC, or
user-specified special signals. It is widely used in
the industrial measurement systems, medical
electronic equipment, electrical equipment etc.
We adopt high efficiency magnetism and
electricity isolated technology to achieve signal
isolation, with characteristics of high output
accuracy, good linearity and low temperature
drift.
T1133B
T1130B
T2233B
T2230B
24V
24V
24V
24V
4-20mA
4-20mA
0-20mA
0-20mA
4-20mA
4-20mA
0-20mA
0-20mA
24V
NONE
24V
1
1
1
1
NONE
Note: We could also offer customer design for special input and output.
ELECTRICAL CHARACTERISTICS
Power Supply
Power Dissipation
Power Protection
Output Voltage
Output Current
Input Signal
(Nominal Power Supply)±5%
Power Supply
Data
≤2W
Reverse protection
(Nominal)±10%
≤25mA
Isolation Power
Output Data
See above
Input Data
Input Impedance
Overload
Input 20mA with voltage drop about 250mV
≤300mA
Output Signal
Load
See above
Output Data
≤500Ω(At Output =20mA)
FEATURES
● Three port Isolation(input, output, power supply)
● High accuracy (0.1% F.S.)
TRANSMISSION CHARACTERISTICS
● High linearity (0.1% F.S.)
Offset
0.1%F.S.
● Isolation voltage(2500VDC/60S)
● High frequency response(15KHz)
● Low temperature drift(35PPM/℃)
● Industry class(Operation temp.: -25℃ to +71℃)
● High reliability(MTBF>500,000 hours)
Gain Error
Temperature Drift
0.1%F.S.
0.0035%F.S./℃ (-25℃ to +71℃)
ISOLATION CHARACTERISTICS
Galvanic Isolation
Three port Isolation(input, output, power supply)
Isolation Voltage
2.5KVDC (Tested for 1minute and 1mA max, humidity < 70%)
Insulation
Resistance
100MΩ,500VDC(Among signal input ,signal output, power supply
and isolation power output)
MODEL SELECTION
TXXXXB
OTHER CHARACTERISTICS
Package style
Isolation power output
Power supply
Output
Operation temperature:-25℃ to +71℃
Ambient
temperature
Transport and Storage temperature:-50℃ to +105℃
35mm DIN-rail package
Package
Input
Isolation amplifier
Safety Class
EMC compliance
Weight
IP20(IEC60529 / EN60529)
GB/T 18268(IEC61326-1)
About 60g
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Huangzhou Industrial
District, Guangzhou, China
Tel: 86-20-38601850
Application
environment
No dusts, gases of fiercely vibration, impulsion or gases that may
erode to the components surrounded
Fax:86-20-38601272
Note:
Http://www.mornsun-power.com
1 .All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output
load unless otherwise specified.
2. Only typical models listed, specifications of custom product may be different. Please contact our
service people directly for certain conditions.
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
T11/12/21/22_B A/1-2008 Page 1 of 2
SINGLE CHANNEL SCHEMATIC DIAGRAM
CONNECTION
1. Cross section area of wiring: 0.5mm2-2.5 mm2;
2. Multi-strand wire, the length of bare wire is
about 8mm, fixed by the M4 bolt.
2+
Power supply
-
1
8+
Isolation
power output
7
-
4+
Output
6+
Application Note
Input
5
-
3
-
1. Please read the user manual carefully before
using. If any questions please contact our
technical support department.
APPLICATION CIRCUIT DIAGRAM
2. Please do not use this product in hazardous
area.
1(-)
5(-)
3. The power supply of this product should be DC
power source. It is forbidden to use 220VAC
power supply.
Power supply
Output
Input
2(+)
3(-)
6(+)
4. To avoid equipment invalidation, or any failure,
users’ disassembling this product is forbidden.
7(-)
Isolation
power output
4(+)
8(+)
AFTER SERVICE
1. Products are carefully inspected and
controlled before going out from our factory. If
they operated abnormally or there were
anything wrong in the inner parts, please
contact with our agents near you or technical
support in our company as soon as possible.
2. 3 years warranty since the delivery date.
During the period of quality guarantee,our
company will repair or change free of charge if
product has any quality problem in the process
of normally using.
PACKAGING SIZE AND TERMINAL DESCRIPTION
Power supply-
1-
2+
3-
4+
5-
6+
7-
8+
Power supply+
Output-
MORNSUN
Output+
Input-
Input+
Isolation power output-
Isolation power output+
41
25
Unit: mm
Tolerance:±0.5
INSTALLATION
DISASSEMBLY
DIN35mm standard rail installation
1. Use a screwdriver (Width of edge≤6mm),
cut in the metal card lock from the
underside;
1. Upside of the instrument card in the
rail;
2. Push underside of the instrument into
the rail.
2. Boost up the screwdriver and prize the
metal card lock downwards;
3. Pull the instrument out of the rail.
1
3
2
1
2
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
T11/12/21/22_B
A/1-2008
Page 2 of 2