TS101-EX [MORNSUN]
Isolating / Safety Switching Barrier;型号: | TS101-EX |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | Isolating / Safety Switching Barrier |
文件: | 总3页 (文件大小:461K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FEATURES
●Fitted devices: 1. NAMUR Sensors;
2. Mechanical Joints.
● Phase-angel and inverse control setting;
● Open circuit detection setting
● Operation Temperature:-25°C to +71°C
● Reliable Performance (MTBF>1,000,000 hours)
Isolating / Safety Switching Barrier
(Transistor Output)
——TSX01-EX Series
PART NUMBER SYSTEM
GENERAL DESCRIPTION
TS201-EX
This Isolation Switching Barrier can detect switch or approach
switch’s status in locations where hazardous exists; isolate, transmit
and output it to safe area. Input and output can be set to inverse
control. Approach switch open circuit detection function. Isolation
between Input/ Output/Power source.
Safety barrier mark
Transistor output
Channel number
Signal style
Product seriers
PRODUCT PROGRAM
Input(Power)
Voltage(VDC)
Output(Hazardous end)
Output
(Safe end)
Channel
numbers
Part number
Voltage
Typ.
Short Circuit
Current
Typ.
Range
TS101
TS201
1
2
1
2
24
18-36
8VDC
About 8 mA
Transistor Output
TS101-EX
TS201-EX
ELECTRICAL SPECIFICATIONS
Operation voltage
18-36VDC
Common parameter
Hazardous Area
Input frequency
Power indicating
Input Signal
About 2.4W
LED light (green) ON when operating
Switch status of NAMUR sensor, mechanical joint etc
Distribution voltage
Short circuit current
About 8V (Open status)
About 8mA
Input switching frequency
Open circuit threshold current
Switching threshold
Output signal
≤5kHz
≤0.1mA
Typ:1.55mA (hysteresis:0.2mA)
Transistor output (Passive pulse)
≤40VDC
External source
Safe Area
Driving capability
≤40mA(Build-in short circuit protection)
High Level: Vcc ; Low Level: ≤2.5VDC
High Level: Vcc-2.5V ; Low Level: ≤0.5VDC
Transistor collector
Transistor Emitter
TRANSMISSION SPECIFICATIONS
Input loop current > 2.1mA, transistor output open, channel indicator light (red) ON.
Under phase-angel control (K2 K3 OFF )
Input loop current < 1.2mA, transistor output close, channel indicator light (red) OFF.
Input loop current > 2.1mA, transistor output close, channel indicator light (red) OFF.
Input loop current < 1.2mA, transistor output open, channel indicator light (red) ON.
Input loop current < 0.05mA, open circuit alarm, channel red indicator light (yellow) ON.
Under inverse control (K2 K3 ON )
When connected with NAMUR sensor
When connected with common contact joint To achieve open circuit detection function, a 10KΩ resistor must be connected to the switch in
switch parallel.
Note: K2 is setup channel1 to be reverse or not ,K3 is setup channel2 to be reverse or not.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
TSX01-EX
2013.07.01-A/4
Page 1 of 3
ISOLATION SPECIFICATIONS
Output ~ Input: 2.5KVAC
Power Supply ~ Input: 2.5KVAC
Power Supply ~ Output: 1.5KVAC
Output 1 ~ Output 2: 1.5KVAC
Input 1 ~ Input 2: 1.5VAC
Five-port isolation
Electrical isolation
Isolation strength
EMC
Three-port isolation (Single channel); Five-port isolation(Dual channels)
2.5KVAC (test for 1minute, humidity < 70%)
EN61326
STANDARDS & CERTIFICATES
Explosion protection Certificate mark
[Exia]IIC
Between the pin 11 and 12:
Explosion protection certificate parameters
Um=250VAC/DC
Po=14mW
Uo=10.5VDC
Co=1.68µF
Io=5.3mA
Lo=1000mH
CHINA NATIONAL QUALITY SUPERVISION AND TEST CENTRE FOR EXPLOSION
PROTECTED ELECTRICAL PRODUCTS
Explosion protection certificate agency
Explosion qualified NO.
CNEx08.0003
OTHER SPECIFICATIONS
Operation temperature:-25°C ~ +71°C
Transport and Storage temperature:-50°C ~ +105°C
Ambient temperature
Mounting
Safety Grade
Weight
35mm DIN-rail package, hot plug, thickness: 22.5mm, Plastic UL94-V0
IP20(IEC60529 / EN60529)
About 128g
CONNECTION
In intrinsic safety explosion protection systems, isolating barrier belongs to affiliated device. It is installed at safe area, as a connection between
intrinsic safety devices in the hazardous area and non-intrinsic safety devices in the safe area. By limiting the energy to a certain safe amount, it
ensures the safety of in spot devices and people.
Selection regulations for intrinsic safety explosion protection system:
1.The explosion protection grade of the barrier must be equal to or higher than that of in spot intrinsic safety explosion protection device.
2.Take inconsideration of hazardous end output resistance and loop resistance, ake sure the barrier’s output voltage meets the minimum operation
voltage requirement of in spot intrinsic safety device.
3.The safety parameters of Barrier’s intrinsic safety end meets:
Uo ≤ UI, Io ≤ Iin, Po ≤ Pin
Co ≥ Cin, Lo ≥ Lin
4.Select suitable Safety barrier which matches the in spot intrinsic safety device for the power’s phase, signal type and transmission mode.
5.Apply necessary protections, avoid influence the in spot intrinsic safety device’s operation from leakage current that generated by safety barrier.
Operation notes:
1. Please read the user manual carefully before using. If any questions please contact our technical support department.
2. Please do not use this product in hazardous area.
3. The power supply of this product should be 24VDC power source. It is forbidden to use 220VAC power supply.
4. To avoid invalid explosion protection function, or any failure, users disassemble this product is forbidden.
APPLICATION CIRCUIT DIAGRAM & PIN DESCRIPTION
Safe area
Hazardous area
16
15
12
11
7
Channel1 DCS
8
3
4
PLC
Channel2
5
6
Power
Note:In single model channel2 is invaid
Transistor output mode and connections (safe area):
VCC
VCC
RL=2~20KΩ
Passive pulse
Passive pulse
RL=2~20KΩ
Transistor collector output
Transistor Emitter output
The copyright and authority for the interpretation of the products are reserved by MORNSUN
TSX01-EX
2013.07.01-A/4
Page 2 of 3
INSTALLATION & DISASSEMBLY
Installation
Disassembly
DIN35mm standard rail installation:
1. Use a screwdriver (Width of edge ≤ 6mm), cut in the metal card lock
from the underside;
1.Insert the top of the instrument card in the rail;
2.Push the bottom of the instrument into the rail.
2. Boost up the screwdriver and pry the metal card lock downwards;
3. Pull the instrument out of the rail.
3
1
2
PACKAGING DIMENSION & PACKAGING DIAGRAM
Note:
1. All specifications are measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
2. In this datasheet, all the test setup and methods are based on our corporate standards.
3. All characteristics are for listed models, and non-standard models may perform differently. Please contact our technical support for more details.
4. Please contact our technical support for any specific requirement.
5. Specifications of this product are subject to changes without prior notice.
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
E-mail: info@mornsun.cn
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
TSX01-EX
2013.07.01-A/4
Page 3 of 3