URA1D05YMD-6WR3 [MORNSUN]
6W, ultra wide input isolated & regulated dual / single output DC-DC converter;型号: | URA1D05YMD-6WR3 |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | 6W, ultra wide input isolated & regulated dual / single output DC-DC converter |
文件: | 总8页 (文件大小:2779K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC/DC Converter
URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Series
6W, ultra wide input isolated & regulated dual / single
output DC-DC converter
FEATURES
Ultra wide input voltage range (4:1)
High efficiency up to 86%
Isolation voltage: 2.25K VDC
Operating temperature range: -40℃ to +85℃
Input Under-voltage Protection, Output short
circuit, over-current, over–voltage protection
Low ripple & noise
Reverse voltage protection available with
A2S(Chassis mounting) or A4S(35mm DIN-Rail
mounting)
EN62368 approval(URA1D_YMD-6WR3)
EN60950 approval(URB1D_YMD-6WR3)
Meets requirements of railway standard
EN50155(URB1D_YMD-6WR3)
International standard pin-out
RoHS Patent Protection
URA1D_YMD-6WR3 & URB1D_YMD-6WR3 series are isolated 6W DC-DC products with 40-160VDC input voltage .They feature efficiency up to
86%, 2250VDC isolation, operating temperature of -40 ℃ to +85℃, Input Under-voltage Protection, Output short circuit, over-current,
over–voltage protection. Railway vehicle electronic equipment widely used in 72V, 96V and 110V.
Selection Guide
③
Input Voltage (VDC)
Output
Efficiency
Max.
①
certification
Part No.
Capacitive
Load(µF)
Nominal
(Range)
Output Voltage
(VDC)
Output Current (mA) (%,Min./Typ.)
②
Max.
(Max./Min.)
@ Full Load
470
100
100
1000
470
220
100
URA1D05YMD-6WR3
URA1D12YMD-6WR3
URA1D15YMD-6WR3
URB1D05YMD-6WR3
URB1D12YMD-6WR3
URB1D15YMD-6WR3
URB1D24YMD-6WR3
±5
±12
±15
5
±600/0
±250/0
±200/0
1200/0
500/0
78/80
82/84
83/85
78/80
82/84
83/85
84/86
CE
110
170
(40-160)
12
CE
15
400/0
24
250/0
Note:
①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting , with suffix “A4S” are DIN-Rail mounting, for example
URB1D05YMD-6WHR3A2S is chassis mounting of with heat sink, URB1D05YMD-6WR3A4S is DIN-Rail mounting of without heat sink; If the application has a higher
requirement for heat dissipation, you can choose modules with heat sink;
②Absolute maximum rating without damage on the converter, but it isn't recommended;
③Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection, minimum
efficiency greater than Min.-2 is qualified.
Input Specifications
Item
Operating Conditions
Min.
--
Typ.
68/3
25
Max.
70/8
--
Unit
mA
Input Current (full load / no-load) Nominal input voltage
Reflected Ripple Current
Surge Voltage (1sec. max.)
Starting Voltage
Shutdown Voltage
Starting Time
Nominal input voltage
--
-0.7
--
--
180
40
--
VDC
ms
28
--
33
--
Nominal input voltage & constant resistance load
Module switch on
10
--
Input Filter
Pi filter
Hot Plug
Unavailable
Ctrl suspended or connected to TTL high level
(3.5-12VDC)
Ctrl pin connected to GND or low level
Ctrl*
Module switch off
(0-1.2VDC)
Input current when switched off
mA
--
3
8
Note: *The voltage of Ctrl pin is relative to input pin GND.
2018.06.05-A/4
Page 1 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Series
Output Specifications
Item
Operating Conditions
Min.
--
Typ.
±1
Max.
±3
Unit
①
Output Voltage Accuracy
Positive output
--
±0.2
±0.5
±0.5
±0.5
±1
Full load, the input voltage is
from low voltage to high voltage
Line Regulation
Negative output
URB1D_YMD-6WR3
--
0%-100% load
5%-100% load
--
±1
%
URA1D_YMD-6WR3
Positive output
URA1D_YMD-6WR3
Negative output
②
±0.5
±0.5
--
±1
Load Regulation
±1.5
±10
Dual output, main circuit with 50% load,
auxiliary circuit with 25% -100% load
Cross Regulation
--
Transient Recovery Time
--
--
300
±3
500
±8
µs
%
25% load step change,
nominal input voltage
5V /±5 output
Others
Transient Response Deviation
--
±3
±5
%/℃
mV p-p
%Vo
Temperature Coefficient
③
Ripple & Noise
Full load
--
±0.02
50
±0.03
100
160
210
20MHz bandwidth , 5%-100% load
Input voltage range
--
Over-voltage Protection
Over-current Protection
Short circuit Protection
110
120
--
--
%Io
Continuous, self-recovery
Note: ①At 0%-5% load, the Max. output voltage accuracy of ±5VDC output converter negative output is ±5%;
②When testing from 0% to100%load working conditions,load regulation of URA1D_YMD-6WR3 series index of ±5%;
③Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods. 0%-5% load
ripple&Noise is no more than 5%Vo.
General Specifications
Item
Operating Conditions
Input-output, with the test time of 1 minute and the
leak current lower than 1mA.
Input and output respectively on the shell, with the test
time of 1 minute and the leak current lower than 1mA.
Min.
Typ.
--
Max.
--
Unit
2250
Insulation Voltage
VDC
1600
--
--
MΩ
Insulation Resistance
Isolation Capacitance
Operating Temperature
Storage Temperature
Input-output, isoiation voltage 500VDC
Input-output, 100KHz/0.1V
see Fig.1
1000
--
--
1000
--
--
--
pF
-40
-55
+85
+125
--
℃
Pin Welding Resistance
Temperature
Welding spot is 1.5mm away from the casing, 10
seconds.
--
5
--
--
+300
95
Storage Humidity
Vibration
Non-condensing
%RH
IEC61373 car body 1 B mold
--
Switching Frequency *
PWM Mode
--
300
KHz
MIL-HDBK-217F@25℃
MTBF
1000
--
--
K hours
Note:* This series of products using reduced frequency technology, the switching frequency is test value of full load,When the load is reduced to below 50%, the
switching frequency decreases with decreasing load.
Physical Specifications
Casing Material
Aluminum alloy
Horizontal package( without heat sink)
Horizontal package( with heat sink)
A2S wiring package ( without heat sink)
A2S wiring package( with heat sink)
A4S rail package( without heat sink)
A4S rail package( with heat sink)
25.40*25.40*11.70 mm
25.40*25.40*16.20 mm
76.00*31.50*21.20 mm
76.00*31.50*25.20 mm
76.00*31.50*25.80 mm
76.00*31.50*29.80 mm
Dimensions
without heat sink Horizontal package/A2S wiring package/A4S rail package 15g/35g/54g(Typ.)
Weight
with heat sink
Horizontal package/A2S wiring package/A4S rail package 20g/40g/59g(Typ.)
Free air convection
Cooling Methods
2018.06.05-A/4
Page 2 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Series
EMC Specifications
CE
CISPR32/EN55032 CLASS B (see Fig.3 or Fig.4-② for recommended circuit)
EMI
RE
CISPR32/EN55032 CLASS B (see Fig.3 or Fig.4-② for recommended circuit)
IEC/EN61000-4-2 Contact ±6KV/Air ±8KV
ESD
RS
perf. Criteria B
perf. Criteria A
perf. Criteria B
IEC/EN61000-4-3 20V/m
EFT
IEC/EN61000-4-4 ±4KV(see Fig.3 or Fig.4-① for recommended circuit)
EMS
IEC/EN61000-4-5 line to line ±2KV (2Ω 18uF see Fig.3 for recommended circuit)
line to ground ±4KV (12Ω 9uF see Fig.3 for recommended circuit)
Surge
CS
perf. Criteria B
perf. Criteria A
IEC/EN61000-4-6 10 Vr.m.s
EMC Specifications(EN50155)
EN50121-3-2 150kHz-500kHz 99dBuV
CE
500kHz-30MHz 93dBuV
EN50121-3-2 30MHz-230MHz 40dBuV/m at 10m
230MHz-1GHz 47dBuV/m at 10m
EMI
RE
ESD
RS
EN50121-3-2 Contact ±6KV/Air ±8KV
EN50121-3-2 20V/m
perf. Criteria B
perf. Criteria A
perf. Criteria A
EFT
EN50121-3-2 ±2kV 5/50ns 5kHz
EMS
EN50121-3-2 line to line ±1KV(42Ω, 0.5μF)
line to ground ±2KV(42Ω, 0.5μF)
Surge
CS
perf. Criteria B
perf. Criteria A
EN50121-3-2 0.15MHz-80MHz 10Vr.m.s
Note:All the tests are testing under the conditions of inputs capacitor 100uF/200V or FC-C01D.
Product Characteristic Curve
Temperature Derating Curve
120
100
80
60
40
20
0
without heatsink
Safe Operating Area
with hea tsink
-40
0
40
717585
120
Operating Temperature(℃ )
Fig. 1
2018.06.05-A/4
Page 3 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Series
Design Reference
1. Typical application
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.
If a further decrease of the input and output ripple is required, properly increase the input & output of additional capacitors Cin and Cout
or select capacitors of low equivalent impedance,and ensure the capacitance should be lower than the max. capacitive load of the
product.
Dual Output
+Vo
Vin
Cout
0V
Cin
DC
DC
DC
DC
Cout
GND
-Vo
Cin
Cout
10µF
Single Output
Vin
10µF -47µF
+Vo
0V
Cout
Cin
GND
Fig. 2
2. EMC solution-recommended circuit
CY 1
FUSE
+Vin
+Vo
Vin
+
FC-C01D
DC-DC
-Vin
LOAD
C2
C0 C1
-Vo
(0V)
GND
CY 2
Fig. 3
Fig.3 Parameter description:
FUSE
Choose according to actual input current
FC-CX1D is the EMC auxiliary component of our
company. Input voltage range: 40V-160V
FC-C01D
C0
100µF/200V
C1
Refer to the Cin in Fig.2
Refer to the Cout in Fig.2
1nF /3KV
C2
CY1、CY2
2018.06.05-A/4
Page 4 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Series
Fig. 4 Parameter description:
C0
C1、C2、C3、C4
L1
100uF/200V
0.22uF/250V
68μH
CY1、CY2
1nF/3KV
Fig. 4
3. It is not allowed to connect modules output in parallel to enlarge the power
4. For more information about Mornsun EMC Filter products, please visit www.mornsun-power.com to
download the Selection Guide of EMC Filter
Horizontal Package (without heat sink) Dimensions and Recommended Layout
2018.06.05-A/4
Page 5 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Series
Horizontal Package (with heat sink) Dimensions
URA1D_YMD-6WR3A2S & URB1D_YMD-6WR3A2S (without heat sink) Dimensions
2018.06.05-A/4
Page 6 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Series
URA1D_YMD-6WHR3A2S & URB1D_YMD-6WHR3A2S (with heat sink) Dimensions
URA1D_YMD-6WR3A4S & URB1D_YMD-6WR3A4S (without heat sink) Dimensions
2018.06.05-A/4
Page 7 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Series
URA1D_YMD-6WHR3A4S & URB1D_YMD-6WHR3A4S(with heat sink) Dimensions
Note:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com.The
Packing bag number of Horizontal package :58210003(without heat sink), 58200048(with heat sink, A2S/ A4S package number:
58220022;
2. The maximum capacitive load offered were tested at input voltage range and full load;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25℃, humidity<75%RH with nominal
input voltage and rated output load;
4. Other product application information, please see DC-DC(railway power supply)Converter Application Notes for specific operation
methods--2016 Edition.
5. All index testing methods in this datasheet are based on Company’s corporate standards;
6. We can provide product customization service, please contact our technicians directly for specific information;
7. Products are related to laws and regulations: see "Features" and "EMC";
8. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by
qualified units.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: info@mornsun.cn
2018.06.05-A/4
Page 8 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
相关型号:
URA1D12YMD-6WR3
6W, ultra wide input isolated & regulated dual / single output DC-DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
URA1D15YMD-6WR3
6W, ultra wide input isolated & regulated dual / single output DC-DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
URA1H4R7MDR-TP
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 50V, 20% +Tol, 20% -Tol, 4.7uF, Through Hole Mount, 5 MML RADIAL LEADED, CANWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NICHICON
URA1V220MDR-TD
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 35V, 20% +Tol, 20% -Tol, 22uF, Through Hole Mount, 5 MML RADIAL LEADED, CANWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NICHICON
URA2405D-10W
DUAL/SINGLE OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
URA2405D-30W
DUAL/ SINGLE OUTPUT DIP DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
URA2405D-30WH
Analog CircuitWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
URA2405D-30WR2
DUAL/ SINGLE OUTPUT DIP DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
URA2405D-5W
DUAL/SINGLE OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
URA2405LD-15W
Analog CircuitWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
URA2405LD-15WHR2
Analog CircuitWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
URA2405LD-15WR2
Analog CircuitWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MORNSUN
©2020 ICPDF网 联系我们和版权申明