URB1D12LMD-20WR3 [MORNSUN]
Ultra wide input voltage range;型号: | URB1D12LMD-20WR3 |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | Ultra wide input voltage range |
文件: | 总9页 (文件大小:3907K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC/DC Converter
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series
15&20W, Ultra wide input isolated & regulated
DC/DCconverter
FEATURES
Ultra wide input voltage range (4:1)
Enhanced isolation, isolation voltage: 2250VDC
Operating temperature range: -40℃ to +85℃
Input Under-voltage Protection, Output short
circuit, over-current, over–voltage protection
Low ripple & noise
EMI meet EN50121-3-2, without external
components
Meets requirements of railway standard
EN50155
Meet the IEC60950, UL60950, EN60950 approval
Reverse voltage protection available with
A2S(Chassis mounting) or A4S(35mm DIN-Rail
mounting)
International standard pin-out
Patent Protection RoHS
URB1D_LMD-15WR3 series are isolated 15W DC-DC products with 4:1 input voltage. URB1D_LMD-20WR3 series are isolated 20W DC-DC
products with 4:1 input voltage. Their feature efficiency up to 86%, 2250VDC isolation with Enhanced isolation, operating temperature of
-40℃ to +85℃, Input Under-voltage Protection, Output short circuit, over-current, over–voltage protection.Railway vehicle electronic
equipment widely used in 72V, 96V and 110V.
Selection Guide
③
Input Voltage (VDC)
Output
Output Current
Efficiency
(%,Min./Typ.)
@ Full Load
Max. Capacitive
Load(µF)
①
Part No.
Certification
Nominal
Output Voltage
(VDC)
②
Max.
(mA)(Max./Min.)
(Range)
URB1D03LMD-15WR3
URB1D05LMD-15WR3
URB1D12LMD-15WR3
URB1D15LMD-15WR3
URB1D24LMD-15WR3
URB1D03LMD-20WR3
URB1D05LMD-20WR3
URB1D12LMD-20WR3
URB1D15LMD-20WR3
URB1D24LMD-20WR3
3.3
5
4000/0
80/82
82/84
82/84
83/85
83/85
80/82
82/84
83/85
84/86
84/86
5400
5400
1000
820
3000/0
12
15
24
3.3
5
1250/0
1000/0
625/0
270
110
170
--
(40-160)
5000/0
10000
10000
1600
1000
470
4000/0
12
15
24
1667/0
1333/0
833/0
Note:
①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting,with suffix “A4S” are DIN-Rail mounting, for example
URB1D05LMD-20WHR3A2S is chassis mounting of with heat sink, URB1D05LMD-20WR3A4S is DIN-Rail mounting of without heat sink; If the application has a
higher requirement for heat dissipation, you can choose modules with heat sink;
②Absolute maximum rating without damage on the converter, but it isn't recommended;
③Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection, minimum
efficiency greater than Min.-2 is qualified.
Input Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
mA
3.3V output
5V output
Others
--
--
--
147/10
163/10
159/3
150/20
167/20
166/8
URB1D_LMD-15WR3 series,
Nominal input voltage
Input Current (full load /
no-load)
3.3V output
--
183/10
188/20
URB1D_LMD-20WR3 series,
Nominal input voltage
5V output
Others
--
--
--
217/10
214/3
25
222/20
219/8
--
Reflected Ripple Current
Nominal input voltage
2016.11.03-A/0
Page 1 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series
Surge Voltage (1sec. max.)
-0.7
--
--
--
180
40
--
VDC
ms
Starting Voltage
Shutdown Voltage
Starting Time
Input Filter
100% load
33
10
28
--
Nominal input voltage & constant resistance load
--
Pi filter
Hot Plug
Unavailable
Ctrl suspended or connected to TTL high level
(3.5-12VDC)
Module switch on
Ctrl*
Module switch off
Ctrl pin connected to GND or low level (0-1.2VDC)
Input current when switched off
mA
--
2
7
Note: * the voltage of Ctrl pin is relative to input pin GND.
Output Specifications
Item
Operating Conditions
Min.
--
Typ.
±1
Max.
Unit
Output Voltage Accuracy
0%-100% load
±3
Full load, the input voltage is from low voltage to
high voltage
Line Regulation
±0.2
±0.5
%
--
Load Regulation
0%-100% load
±0.5
300
±3
±1
500
±8
--
--
--
--
Transient Recovery Time
µs
%
25% load step change,
3.3V/5V output
nominal input voltage
Transient Response Deviation
Others
±3
±5
%/℃
Temperature Coefficient
Ripple & Noise *
Full load
--
--
±0.02
50
±0.03
100
20MHz bandwidth, 5%-100% load
mV p-p
90
--
110
Trim
%Vo
%Io
Over-voltage Protection
Over-current Protection
Short Circuit Protection
110
120
--
--
160
210
Input voltage range
Continuous, self-recovery
Note: *0%-5% load ripple&Noise is no more than 5%Vo.Ripple and noise are measured by ”parallel cable” method, please see DC-DC Converter Application
Notes for specific operation.
General Specifications
Item
Operating Conditions
Input-output, with the test time of 1 minute and the
leak current lower than 1mA.
Min.
Typ.
--
Max.
--
Unit
2250
Insulation Voltage
VDC
Input and output respectively on the shell, with the
test time of 1 minute and the leak current lower
than 1mA.
1600
--
--
Insulation Resistance
Isolation Capacitance
Operating Temperature
Storage Temperature
Storage Humidity
Pin Welding Resistance
Temperature
Switching Frequency*
Shock & Vibration test
MTBF
Input-output, isolation voltage 500VDC
Input-output, 100KHz/0.1V
see Fig. 1
1000
--
--
2200
--
--
--
M
Ω
pF
-40
-55
5
+85
+125
95
℃
--
Non-condensing
Welding spot is 1.5mm away from the casing, 10
seconds
--
%RH
℃
--
--
--
+300
--
300
PWM mode
KHz
IEC 61373, car body 1 B mold
-- --
MIL-HDBK-217F@25
℃
1000
K hours
Note: *This series of products using reduced frequency technology, the switching frequency is test value of full load,When the load is reduced to below 50%, the
switching frequency decreases with decreasing load.
Physical Specifications
Casing Material
Aluminum alloy
Horizontal package
A2S wiring package
A4S rail package
50.80*25.40*11.80mm
76.00*31.50*21.20 mm
76.00*31.50*25.80 mm
Package Dimensions
Without heat sink
2016.11.03-A/0
Page 2 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series
Horizontal package
50.80*25.40*16.30mm
76.00*31.50*25.10 mm
76.00*31.50*29.70 mm
Package Dimensions
With heat sink
A2S wiring package
A4S rail package
Horizontal package/A2S wiring package/A4S rail
package
Without heat sink
With heat sink
26g/48g/68g(Typ.)
Weight
Horizontal package/A2S wiring package/A4S rail
package
34g/56g/76g(Typ.)
Free air convection
Cooling Method
EMC Specifications
CLASS A(see Fig.3 for recommended circuit)/
CLASS B(see Fig.5 for recommended circuit)
CLASS A(without external components)/
CLASS B (see Fig.5 for recommended circuit)
CE
CISPR22/EN55022
EMI
RE
CISPR22/EN55022
ESD
RS
IEC/EN61000-4-2
IEC/EN61000-4-3
IEC/EN61000-4-4
Contact ±6KV/Air ±8KV
perf. Criteria B
10V/m
perf. Criteria A
perf. Criteria B
EFT
±4KV (see Fig.4 or Fig.5 for recommended circuit)
line to line ±2KV (2Ω0.5uF see Fig.4 for recommended circuit)
line to ground ±4KV (12Ω0.5uF see Fig.4 for recommended circuit)
EMS
IEC/EN61000-4-5
perf. Criteria B
Surge
CS
line to line ±1KV (42Ω0.5uF see Fig.5 for recommended circuit)
line to ground ±2KV (42Ω0.5uF see Fig.5 for recommended circuit)
EN50121-3-2
perf. Criteria B
perf. Criteria A
IEC/EN61000-4-6
10 Vr.m.s
Product Characteristic Curve
Temperature Derating Cur ve
120
Temperature Derating Curve
120
With heatsink
40V Vin 120V Without heatsink
Without heatsink
100
80
100
≤
≤
With heatsink
80
60
40
20
0
120V Vin 160 V Without heatsink
<
≤
60
Safe Operating Area
Safe Operating Area
40
20
0
-40
0
40 6571 85
℃
Operating Temperature( )
-40
0
40 6571 85
120
℃
Operating Temperature(
)
URB1D03LMD-20W(H)R3(A2S/A4S) Operating Temperature
Operating Temperature, ExceptURB1D03/05LMD-20W(H)R3(A2S/A4S)
Temperature Derating Curve
120
Temperature Derating Curve
120
①
②
③
④
≤
<
40V Vin 66V Without heatsink
100
80
≤
<
40V Vin 66V With heatsink
120V Vin 160 V Without heatsink
120V Vin 160 V With heatsink
100
66V Vin 120V Wit hout heatsink
≤
≤
①
②
<
≤
80
60
40
≤
≤
66V Vin 120V Wit h heat sink
<
≤
60
Safe Operating Area
Sa fe Op erating Area
40
①
①
②
20
0
③
④
②
20
0
-40
55 606570
85
-40
0
0
40 6571 85
℃
Operating Temperature(
)
℃
Operating Temperature(
)
URB1D05LMD-20W(H)R3(A2S/A4S) Operating Temperature
Fig. 1
2016.11.03-A/0
Page 3 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series
Design Reference
1. Typical application
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product.
Vout(VDC)
3.3/5
Fuse
Cin
Cout
470µF
220µF
100µF
Fuse
Cin
Vin
+Vo
0V
Cout
DC
DC
2A,slow blow
12/15
24
10µF - 47µF
GND
Fig. 2
2. EMC solution-recommended circuit
+Vo
0V
Vin
Fig. 3 Parameter description:
Cin
Cout
DC DC
Cin
27uF -100µF/250V
GND
Cout
Refer to the Cout in Fig.2
Fig. 3
Notes: Fig. 3 Cin please use the 250V withstand voltage of the
capacitor.
CY 1
FUSE
+Vin
+Vo
0V
Vin
+
FC-CX1D
DC-DC
-Vin
LOAD
C2
C0 C1
GND
CY 2
Fig. 4
2016.11.03-A/0
Page 4 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series
Fig. 4 Parameter description:
FUSE
Choose according to actual input current
FC-CX1D is the EMC auxiliary component of our
company. Input voltage range: 40V-160V
FC-CX1D
C0
C1
C2
100µF/200V
Refer to the Cin in Fig.2
Refer to the Cout in Fig.2
CY1、CY2
1000pF/400VAC
LCM1
LCM
2
3
CY
+Vin
+Vo
0V
Vin
CY1
C4
+
LOAD
DC/DC
C3
C0
C1
C2
CY2
GND
-Vin
4
CY
①
②
Fig. 5
Notes: Part ①in the Fig. 4 is used for EMS test and part ②for EMI filtering; selected based on needs.
Fig. 5 Parameter description:
Model
C0
URB1D_LMD-15WR3
URB1D_LMD-20WR3
100µF/200V
0.22µF/250V
C1、C2
C3
Refer to the Cin in Fig.2
15mH
LCM1
LCM2
2.2mH(FL2D-10-222)
(UU common mode inductance)
15mH
0.53mH
(material:TN150P-RH12.7*12.7*7.9)
(UU common mode inductance)
CY1、CY2、
CY3、CY4
1000pF/400VAC
C4
Refer to the Cout in Fig.2
Notes: FL2D-10-222 for MORNSUM EMC auxiliary device
3. Trim application & Trim resistance
+Vot
+Vot
Calculation formula of Trim resistance:
aR2
R2-a
Vref
Vo’-Vref
R1
-R3
-R3
up:
RT=
RT=
a=
a=
R1
R2
RT
R1
R3
Vref
R2
Trim
R3
Vref
R2
aR1
R1-a
Vo’-Vref
Vref
Trim
down:
RT
0V
Trim down
0V
Trim up
Application circuit for TRIM (Part in broken line is the interior of models)
Note: Leave open if not used. RT: Resistance of Trim. a: User-defined parameter, no actual meanings.
Vout(V)
R1(KΩ)
4.801
R2(KΩ)
2.87
R3(KΩ)
10
Vref(V)
1.24
2.5
3.3
5
2.883
2.87
10
12
15
24
11.000
14.384
24.872
2.87
15
2.5
2.87
15
2.5
2.87
17.8
2.5
4. It is not allowed to connect modules output in parallel to enlarge the power
5. For more information please find DC-DC converter application notes on www.mornsun-power.com
2016.11.03-A/0
Page 5 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series
Horizontal Package (without heat sink) Dimensions and Recommended Layout
Horizontal Package (with heatsink) Dimensions
2016.11.03-A/0
Page 6 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series
URB1D_LMD-15WR3A2S & URB1D_LMD-20WR3A2S (without heatsink) Dimensions
URB1D_LMD-15WHR3A2S & URB1D_LMD-20WHR3A2S (with heatsink) Dimensions
2016.11.03-A/0
Page 7 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series
URB1D_LMD-15WR3A4S & URB1D_LMD-20WR3A4S (without heatsink) Dimensions
URB1D_LMD-15WHR3A4S & URB1D_LMD-20WHR3A4S (with heatsink) Dimensions
2016.11.03-A/0
Page 8 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series
Note:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com.The
Packing bag number of Horizontal package :58200035(without heat sink), 58200051(with heat sink), A2S/ A4S package number:
58220022;
2. The maximum capacitive load offered were tested at input voltage range and full load;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25℃, humidity<75%RH with nominal
input voltage and rated output load;
4. All index testing methods in this datasheet are based on Company’s corporate standards;
5. Other product application information, please see DC-DC(railway power supply)Converter Application Notes for specific operation
methods;
6. We can provide product customization service, please contact our technicians directly for specific information;
7. Specifications are subject to change without prior notice.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: info@mornsun.cn
2016.11.03-A/0
Page 9 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation