URB1D12LMD-20WR3 [MORNSUN]

Ultra wide input voltage range;
URB1D12LMD-20WR3
型号: URB1D12LMD-20WR3
厂家: MORNSUN SCIENCE& TECHNOLOGY LTD.    MORNSUN SCIENCE& TECHNOLOGY LTD.
描述:

Ultra wide input voltage range

文件: 总9页 (文件大小:3907K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC/DC Converter  
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series  
15&20W, Ultra wide input isolated & regulated  
DC/DCconverter  
FEATURES  
Ultra wide input voltage range (4:1)  
Enhanced isolation, isolation voltage: 2250VDC  
Operating temperature range: -40to +85℃  
Input Under-voltage Protection, Output short  
circuit, over-current, over–voltage protection  
Low ripple & noise  
EMI meet EN50121-3-2, without external  
components  
Meets requirements of railway standard  
EN50155  
Meet the IEC60950, UL60950, EN60950 approval  
Reverse voltage protection available with  
A2S(Chassis mounting) or A4S(35mm DIN-Rail  
mounting)  
International standard pin-out  
Patent Protection RoHS  
URB1D_LMD-15WR3 series are isolated 15W DC-DC products with 4:1 input voltage. URB1D_LMD-20WR3 series are isolated 20W DC-DC  
products with 4:1 input voltage. Their feature efficiency up to 86%, 2250VDC isolation with Enhanced isolation, operating temperature of  
-40to +85, Input Under-voltage Protection, Output short circuit, over-current, over–voltage protection.Railway vehicle electronic  
equipment widely used in 72V, 96V and 110V.  
Selection Guide  
Input Voltage (VDC)  
Output  
Output Current  
Efficiency  
(%,Min./Typ.)  
@ Full Load  
Max. Capacitive  
Load(µF)  
Part No.  
Certification  
Nominal  
Output Voltage  
(VDC)  
Max.  
(mA)(Max./Min.)  
(Range)  
URB1D03LMD-15WR3  
URB1D05LMD-15WR3  
URB1D12LMD-15WR3  
URB1D15LMD-15WR3  
URB1D24LMD-15WR3  
URB1D03LMD-20WR3  
URB1D05LMD-20WR3  
URB1D12LMD-20WR3  
URB1D15LMD-20WR3  
URB1D24LMD-20WR3  
3.3  
5
4000/0  
80/82  
82/84  
82/84  
83/85  
83/85  
80/82  
82/84  
83/85  
84/86  
84/86  
5400  
5400  
1000  
820  
3000/0  
12  
15  
24  
3.3  
5
1250/0  
1000/0  
625/0  
270  
110  
170  
--  
(40-160)  
5000/0  
10000  
10000  
1600  
1000  
470  
4000/0  
12  
15  
24  
1667/0  
1333/0  
833/0  
Note:  
Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mountingwith suffix “A4S” are DIN-Rail mounting, for example  
URB1D05LMD-20WHR3A2S is chassis mounting of with heat sink, URB1D05LMD-20WR3A4S is DIN-Rail mounting of without heat sink; If the application has a  
higher requirement for heat dissipation, you can choose modules with heat sink;  
Absolute maximum rating without damage on the converter, but it isn't recommended;  
Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection, minimum  
efficiency greater than Min.-2 is qualified.  
Input Specifications  
Item  
Operating Conditions  
Min.  
Typ.  
Max.  
Unit  
mA  
3.3V output  
5V output  
Others  
--  
--  
--  
147/10  
163/10  
159/3  
150/20  
167/20  
166/8  
URB1D_LMD-15WR3 series,  
Nominal input voltage  
Input Current (full load /  
no-load)  
3.3V output  
--  
183/10  
188/20  
URB1D_LMD-20WR3 series,  
Nominal input voltage  
5V output  
Others  
--  
--  
--  
217/10  
214/3  
25  
222/20  
219/8  
--  
Reflected Ripple Current  
Nominal input voltage  
2016.11.03-A/0  
Page 1 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series  
Surge Voltage (1sec. max.)  
-0.7  
--  
--  
--  
180  
40  
--  
VDC  
ms  
Starting Voltage  
Shutdown Voltage  
Starting Time  
Input Filter  
100% load  
33  
10  
28  
--  
Nominal input voltage & constant resistance load  
--  
Pi filter  
Hot Plug  
Unavailable  
Ctrl suspended or connected to TTL high level  
(3.5-12VDC)  
Module switch on  
Ctrl*  
Module switch off  
Ctrl pin connected to GND or low level (0-1.2VDC)  
Input current when switched off  
mA  
--  
2
7
Note: * the voltage of Ctrl pin is relative to input pin GND.  
Output Specifications  
Item  
Operating Conditions  
Min.  
--  
Typ.  
±1  
Max.  
Unit  
Output Voltage Accuracy  
0%-100% load  
±3  
Full load, the input voltage is from low voltage to  
high voltage  
Line Regulation  
±0.2  
±0.5  
%
--  
Load Regulation  
0%-100% load  
±0.5  
300  
±3  
±1  
500  
±8  
--  
--  
--  
--  
Transient Recovery Time  
µs  
%
25% load step change,  
3.3V/5V output  
nominal input voltage  
Transient Response Deviation  
Others  
±3  
±5  
%/℃  
Temperature Coefficient  
Ripple & Noise *  
Full load  
--  
--  
±0.02  
50  
±0.03  
100  
20MHz bandwidth, 5%-100% load  
mV p-p  
90  
--  
110  
Trim  
%Vo  
%Io  
Over-voltage Protection  
Over-current Protection  
Short Circuit Protection  
110  
120  
--  
--  
160  
210  
Input voltage range  
Continuous, self-recovery  
Note: *0%-5% load ripple&Noise is no more than 5%Vo.Ripple and noise are measured by ”parallel cable” method, please see DC-DC Converter Application  
Notes for specific operation.  
General Specifications  
Item  
Operating Conditions  
Input-output, with the test time of 1 minute and the  
leak current lower than 1mA.  
Min.  
Typ.  
--  
Max.  
--  
Unit  
2250  
Insulation Voltage  
VDC  
Input and output respectively on the shell, with the  
test time of 1 minute and the leak current lower  
than 1mA.  
1600  
--  
--  
Insulation Resistance  
Isolation Capacitance  
Operating Temperature  
Storage Temperature  
Storage Humidity  
Pin Welding Resistance  
Temperature  
Switching Frequency*  
Shock & Vibration test  
MTBF  
Input-output, isolation voltage 500VDC  
Input-output, 100KHz/0.1V  
see Fig. 1  
1000  
--  
--  
2200  
--  
--  
--  
M
Ω
pF  
-40  
-55  
5
+85  
+125  
95  
--  
Non-condensing  
Welding spot is 1.5mm away from the casing, 10  
seconds  
--  
%RH  
--  
--  
--  
+300  
--  
300  
PWM mode  
KHz  
IEC 61373, car body 1 B mold  
-- --  
MIL-HDBK-217F@25  
1000  
K hours  
Note: *This series of products using reduced frequency technology, the switching frequency is test value of full load,When the load is reduced to below 50%, the  
switching frequency decreases with decreasing load.  
Physical Specifications  
Casing Material  
Aluminum alloy  
Horizontal package  
A2S wiring package  
A4S rail package  
50.80*25.40*11.80mm  
76.00*31.50*21.20 mm  
76.00*31.50*25.80 mm  
Package Dimensions  
Without heat sink  
2016.11.03-A/0  
Page 2 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series  
Horizontal package  
50.80*25.40*16.30mm  
76.00*31.50*25.10 mm  
76.00*31.50*29.70 mm  
Package Dimensions  
With heat sink  
A2S wiring package  
A4S rail package  
Horizontal package/A2S wiring package/A4S rail  
package  
Without heat sink  
With heat sink  
26g/48g/68g(Typ.)  
Weight  
Horizontal package/A2S wiring package/A4S rail  
package  
34g/56g/76g(Typ.)  
Free air convection  
Cooling Method  
EMC Specifications  
CLASS A(see Fig.3 for recommended circuit)/  
CLASS B(see Fig.5 for recommended circuit)  
CLASS A(without external components)/  
CLASS B (see Fig.5 for recommended circuit)  
CE  
CISPR22/EN55022  
EMI  
RE  
CISPR22/EN55022  
ESD  
RS  
IEC/EN61000-4-2  
IEC/EN61000-4-3  
IEC/EN61000-4-4  
Contact ±6KV/Air ±8KV  
perf. Criteria B  
10V/m  
perf. Criteria A  
perf. Criteria B  
EFT  
±4KV (see Fig.4 or Fig.5 for recommended circuit)  
line to line ±2KV (2Ω0.5uF see Fig.4 for recommended circuit)  
line to ground ±4KV (12Ω0.5uF see Fig.4 for recommended circuit)  
EMS  
IEC/EN61000-4-5  
perf. Criteria B  
Surge  
CS  
line to line ±1KV (42Ω0.5uF see Fig.5 for recommended circuit)  
line to ground ±2KV (42Ω0.5uF see Fig.5 for recommended circuit)  
EN50121-3-2  
perf. Criteria B  
perf. Criteria A  
IEC/EN61000-4-6  
10 Vr.m.s  
Product Characteristic Curve  
Temperature Derating Cur ve  
120  
Temperature Derating Curve  
120  
With heatsink  
40V Vin 120V Without heatsink  
Without heatsink  
100  
80  
100  
With heatsink  
80  
60  
40  
20  
0
120V Vin 160 V Without heatsink  
60  
Safe Operating Area  
Safe Operating Area  
40  
20  
0
-40  
0
40 6571 85  
Operating Temperature( )  
-40  
0
40 6571 85  
120  
Operating Temperature(  
)
URB1D03LMD-20W(H)R3(A2S/A4S) Operating Temperature  
Operating Temperature, ExceptURB1D03/05LMD-20W(H)R3(A2S/A4S)  
Temperature Derating Curve  
120  
Temperature Derating Curve  
120  
40V Vin 66V Without heatsink  
100  
80  
40V Vin 66V With heatsink  
120V Vin 160 V Without heatsink  
120V Vin 160 V With heatsink  
100  
66V Vin 120V Wit hout heatsink  
80  
60  
40  
66V Vin 120V Wit h heat sink  
60  
Safe Operating Area  
Sa fe Op erating Area  
40  
20  
0
20  
0
-40  
55 606570  
85  
-40  
0
0
40 6571 85  
Operating Temperature(  
)
Operating Temperature(  
)
URB1D05LMD-20W(H)R3(A2S/A4S) Operating Temperature  
Fig. 1  
2016.11.03-A/0  
Page 3 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series  
Design Reference  
1. Typical application  
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.  
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or  
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product.  
Vout(VDC)  
3.3/5  
Fuse  
Cin  
Cout  
470µF  
220µF  
100µF  
Fuse  
Cin  
Vin  
+Vo  
0V  
Cout  
DC  
DC  
2Aslow blow  
12/15  
24  
10µF - 47µF  
GND  
Fig. 2  
2. EMC solution-recommended circuit  
+Vo  
0V  
Vin  
Fig. 3 Parameter description:  
Cin  
Cout  
DC DC  
Cin  
27uF -100µF/250V  
GND  
Cout  
Refer to the Cout in Fig.2  
Fig. 3  
Notes: Fig. 3 Cin please use the 250V withstand voltage of the  
capacitor.  
CY 1  
FUSE  
+Vin  
+Vo  
0V  
Vin  
+
FC-CX1D  
DC-DC  
-Vin  
LOAD  
C2  
C0 C1  
GND  
CY 2  
Fig. 4  
2016.11.03-A/0  
Page 4 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series  
Fig. 4 Parameter description:  
FUSE  
Choose according to actual input current  
FC-CX1D is the EMC auxiliary component of our  
company. Input voltage range: 40V-160V  
FC-CX1D  
C0  
C1  
C2  
100µF/200V  
Refer to the Cin in Fig.2  
Refer to the Cout in Fig.2  
CY1CY2  
1000pF/400VAC  
LCM1  
LCM  
2
3
CY  
+Vin  
+Vo  
0V  
Vin  
CY1  
C4  
+
LOAD  
DC/DC  
C3  
C0  
C1  
C2  
CY2  
GND  
-Vin  
4
CY  
Fig. 5  
Notes: Part in the Fig. 4 is used for EMS test and part for EMI filtering; selected based on needs.  
Fig. 5 Parameter description:  
Model  
C0  
URB1D_LMD-15WR3  
URB1D_LMD-20WR3  
100µF/200V  
0.22µF/250V  
C1C2  
C3  
Refer to the Cin in Fig.2  
15mH  
LCM1  
LCM2  
2.2mH(FL2D-10-222)  
(UU common mode inductance)  
15mH  
0.53mH  
(materialTN150P-RH12.7*12.7*7.9)  
(UU common mode inductance)  
CY1CY2、  
CY3CY4  
1000pF/400VAC  
C4  
Refer to the Cout in Fig.2  
Notes: FL2D-10-222 for MORNSUM EMC auxiliary device  
3. Trim application & Trim resistance  
+Vot  
+Vot  
Calculation formula of Trim resistance:  
aR2  
R2-a  
Vref  
Vo’-Vref  
R1  
-R3  
-R3  
up:  
RT=  
RT=  
a=  
a=  
R1  
R2  
RT  
R1  
R3  
Vref  
R2  
Trim  
R3  
Vref  
R2  
aR1  
R1-a  
Vo’-Vref  
Vref  
Trim  
down:  
RT  
0V  
Trim down  
0V  
Trim up  
Application circuit for TRIM (Part in broken line is the interior of models)  
Note: Leave open if not used. RT: Resistance of Trim. a: User-defined parameter, no actual meanings.  
Vout(V)  
R1(KΩ)  
4.801  
R2(KΩ)  
2.87  
R3(KΩ)  
10  
Vref(V)  
1.24  
2.5  
3.3  
5
2.883  
2.87  
10  
12  
15  
24  
11.000  
14.384  
24.872  
2.87  
15  
2.5  
2.87  
15  
2.5  
2.87  
17.8  
2.5  
4. It is not allowed to connect modules output in parallel to enlarge the power  
5. For more information please find DC-DC converter application notes on www.mornsun-power.com  
2016.11.03-A/0  
Page 5 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series  
Horizontal Package (without heat sink) Dimensions and Recommended Layout  
Horizontal Package (with heatsink) Dimensions  
2016.11.03-A/0  
Page 6 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series  
URB1D_LMD-15WR3A2S & URB1D_LMD-20WR3A2S (without heatsink) Dimensions  
URB1D_LMD-15WHR3A2S & URB1D_LMD-20WHR3A2S (with heatsink) Dimensions  
2016.11.03-A/0  
Page 7 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series  
URB1D_LMD-15WR3A4S & URB1D_LMD-20WR3A4S (without heatsink) Dimensions  
URB1D_LMD-15WHR3A4S & URB1D_LMD-20WHR3A4S (with heatsink) Dimensions  
2016.11.03-A/0  
Page 8 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB1D_LMD-15WR3 & URB1D_LMD-20WR3 Series  
Note:  
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com.The  
Packing bag number of Horizontal package :58200035(without heat sink), 58200051(with heat sink), A2S/ A4S package number:  
58220022;  
2. The maximum capacitive load offered were tested at input voltage range and full load;  
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75%RH with nominal  
input voltage and rated output load;  
4. All index testing methods in this datasheet are based on Company’s corporate standards;  
5. Other product application information, please see DC-DCrailway power supplyConverter Application Notes for specific operation  
methods;  
6. We can provide product customization service, please contact our technicians directly for specific information;  
7. Specifications are subject to change without prior notice.  
Mornsun Guangzhou Science & Technology Co., Ltd.  
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China  
Tel: 86-20-38601850-8801  
Fax: 86-20-38601272  
E-mail: info@mornsun.cn  
2016.11.03-A/0  
Page 9 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  

相关型号:

URB1D12XD-10W

DC/DC Converter
MORNSUN

URB1D12YMD-6W

DC-DC converter
MORNSUN

URB1D12YMD-6WR3

Ultra wide input voltage range
MORNSUN

URB1D15LD-15W

DC/DC Converter
MORNSUN

URB1D15LD-20W

DC/DC Converter
MORNSUN

URB1D15LD-20WR3

20W isolated DC-DC converter with Ultra-wide Input and Regulated Single Output
MORNSUN

URB1D15LMD-10WR3

Enhanced isolation, isolation voltage
MORNSUN

URB1D15LMD-15WR3

Ultra wide input voltage range
MORNSUN

URB1D15LMD-20WR3

Ultra wide input voltage range
MORNSUN

URB1D15XD-10W

DC/DC Converter
MORNSUN

URB1D15YMD-6W

DC-DC converter
MORNSUN

URB1D15YMD-6WR3

Ultra wide input voltage range
MORNSUN