URB1D24LMD-10WR3 [MORNSUN]
Enhanced isolation, isolation voltage;![URB1D24LMD-10WR3](http://pdffile.icpdf.com/pdf2/p00329/img/icpdf/URB1D03LMD-1_2025836_icpdf.jpg)
型号: | URB1D24LMD-10WR3 |
厂家: | ![]() |
描述: | Enhanced isolation, isolation voltage |
文件: | 总8页 (文件大小:4377K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
DC/DC Converter
URB1D_LMD-10WR3 Series
10W, ultra wide input isolated & regulated
single output DC-DC converter
FEATURES
Ultra wide input voltage range (4:1)
High efficiency up to 85%
Enhanced isolation, isolation voltage: 2250VDC
Operating temperature range: -40℃ to +85℃
Input under-voltage Protection, Output short
circuit, over-current, over–voltage protection
Low ripple & noise
EMI meet EN50121-3-2 & CISPR22/EN55022 CLASS
A, without external components
Meets requirements of railway standard
EN50155
Meet the IEC60950, UL60950, EN60950 approval
Reverse voltage protection available with
A2S(Chassis mounting) or A4S(35mm DIN-Rail
mounting)
International standard pin-out
RoHS Patent Protection
URB1D_LMD-10WR3 series are isolated 10W DC-DC products with 4:1 input voltage .Their feature efficiency up to 85%, 2250VDC isolation with
enhanced isolation, operating temperature of -40 ℃to +85℃, Input Under-voltage Protection, Output short circuit, over-current,
over–voltage protection. Railway vehicle electronic equipment widely used in 72V, 96V and 110V.
Selection Guide
③
Input Voltage (VDC)
Output
Efficiency
(%, Min./Typ.)
@ Full Load
Max.
Capacitive
Load(µF)
①
certification
Part No.
Nominal
Output Voltage
(VDC)
Output Current (mA)
②
Max.
(Max./Min.)
(Range)
URB1D03LMD-10WR3
3.3
2400/0
74/76
5400
5400
470
URB1D05LMD-10WR3
URB1D12LMD-10WR3
URB1D15LMD-10WR3
URB1D24LMD-10WR3
5
2000/0
833/0
667/0
417/0
78/80
82/84
82/84
83/85
110
170
--
12
15
24
(40-160)
330
100
Note:
①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting,with suffix “A4S” are DIN-Rail mounting, for example
URB1D05LMD-10WHR3A2S is chassis mounting of with heat sink, URB1D05LMD-10WR3A4S is DIN-Rail mounting of without heat sink; If the application has a
higher requirement for heat dissipation, you can choose modules with heat sink;
②Absolute maximum rating without damage on the converter, but it isn't recommended;
③Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection, minimum
efficiency greater than Min.-2 is qualified.
Input Specifications
Item
Operating Conditions
Nominal input voltage
Nominal input voltage
Min.
--
Typ.
95/3
110/3
Max.
98/8
Unit
mA
3.3V output
Others
Input Current (full load / no-load)
--
117/8
Reflected Ripple Current
Surge Voltage (1sec. max.)
Starting Voltage
--
-0.7
--
28
--
25
--
--
--
180
40
--
100% load
VDC
ms
Shutdown Voltage
33
Nominal input voltage & constant resistance
load
Starting Time
Input Filter
Hot Plug
10
--
Pi filter
Unavailable
2016.11.07-A/0
Page 1 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-10WR3 Series
Output Specifications
Item
Operating Conditions
0%-100% load
Min.
--
Typ.
±1
Max.
±3
Unit
%
Output Voltage Accuracy
Full load, the input voltage is from low voltage to
high voltage
Line Regulation
--
±0.2
±0.5
Load Regulation
0%-100% load
--
--
±0.5
300
±3
±1
500
±8
Transient Recovery Time
µs
%
25% load step change,
3.3V/5V output
--
nominal input voltage
Transient Response Deviation
Others
--
±3
±5
Temperature Coefficient
①
Ripple & Noise
Full load
--
±0.02
50
±0.03
100
160
210
%/
℃
20MHz bandwidth , 5%-100% load
--
mV p-p
%Vo
Over-voltage Protection
Over-current Protection
Short circuit Protection
110
120
--
Input voltage range
--
%Io
Continuous, self-recovery
Note: ①0%-5% load ripple&Noise is no more than 5%Vo.Ripple and noise are measured by ”parallel cable” method, please see DC-DC Converter Application
Notes for specific operation.
General Specifications
Item
Operating Conditions
Input-output, with the test time of 1 minute and
the leak current lower than 1mA.
Min.
Typ.
--
Max.
--
Unit
2250
Insulation Voltage
VDC
Input and output respectively on the shell, with
the test time of 1 minute and the leak current
lower than 1mA.
1600
--
--
MΩ
Insulation Resistance
Isolation Capacitance
Input-output, insulation voltage 500VDC
Input-output, 100KHz/0.1V
1000
--
--
--
--
2200
pF
Operating Temperature
see Fig.1
-40
--
+85
℃
Storage Temperature
-55
--
--
--
+125
+300
95
Pin Welding Resistance
Temperature
Storage Humidity
Welding spot is 1.5mm away from the casing,
10 seconds.
Non-condensing
5
--
%RH
Vibration
IEC61373 car body 1 B mold
--
Switching Frequency *
MTBF
PWM Mode
--
300
--
KHz
1000
--
K hours
MIL-HDBK-217F@25℃
Note:* This series of products using reduced frequency technology, the switching frequency is test value of full load,When the load is reduced to below 50%, the
switching frequency decreases with decreasing load.
Physical Specifications
Casing Material
Aluminum alloy
50.80*25.40*11.80 mm
Horizontal package( without heat sink)
Horizontal package( with heat sink)
A2S wiring package ( without heat sink)
A2S wiring package( with heat sink)
A4S rail package( without heat sink)
A4S rail package( with heat sink)
50.80*25.40*16.30 mm
76.00*31.50*21.20 mm
76.00*31.50*25.10 mm
76.00*31.50*25.80 mm
76.00*31.50*29.70 mm
Dimensions
without heat sink
with heat sink
Horizontal package/A2S wiring package/A4S rail package 26g/48g/68g(Typ.)
Horizontal package/A2S wiring package/A4S rail package 34g/56g/76g(Typ.)
Free air convection
Weight
Cooling Methods
2016.11.07-A/0
Page 2 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-10WR3 Series
EMC Specifications
CE
CISPR22/EN55022 CLASS A (without external components)/ CLASS B (see Fig.4 forrecommended circuit)
EMI
RE
CISPR22/EN55022 CLASS A (without external components)/CLASS B (see Fig.4 for recommended circuit)
ESD
RS
IEC/EN61000-4-2
IEC/EN61000-4-3
IEC/EN61000-4-4
Contact ±6KV/Air ±8KV
perf. Criteria B
perf. Criteria A
perf. Criteria B
10V/m
EFT
±4KV(see Fig.3 or Fig.4 for recommended circuit)
line to line ±2KV (2Ω 0.5uF see Fig.3 for recommended circuit)
line to ground ±4KV (12Ω 0.5uF see Fig.3 for recommended circuit)
line to line ±1KV (42Ω 0.5uF see Fig.4 for recommended circuit)
line to ground ±2KV (42Ω 0.5uF see Fig.4 for recommended circuit)
EMS
IEC/EN61000-4-5
perf. Criteria B
Surge
CS
EN50121-3-2
perf. Criteria B
perf. Criteria A
IEC/EN61000-4-6
10 Vr.m.s
Product Characteristic Curve
Temperature Derating Curve
120
100
80
without heatsink
60
Safe Operating Area
with heatsink
40
20
0
-40
0
40
717585
Operating Temperature(
)
℃
Fig. 1
2016.11.07-A/0
Page 3 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-10WR3 Series
Design Reference
1. Typical application
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.
If a further decrease of the input and output ripple is required, properly increase the input & output of additional capacitors Cin and Cout
or select capacitors of low equivalent impedance,and ensure the capacitance should be lower than the max. capacitive load of the
product.
Vout(VDC)
3.3/5
Fuse
Cin
Cout
100µF
47µF
Fuse
Cin
Vin
+Vo
0V
Cout
DC
DC
2A,slow blow
12/15
24
10µF - 47µF
GND
Fig. 2
22µF
2. EMC solution-recommended circuit
CY 1
FUSE
+Vin
+Vo
Vin
+
FC-CX1D
DC-DC
-Vin
LOAD
C2
C0 C1
GND
0V
CY 2
Fig. 3
Fig. 3 Parameter description:
FUSE
Choose according to actual input current
FC-CX1D
FC-CX1D is the EMC auxiliary component of our
company. Input voltage range: 40V-160V
100µF/200V
Refer to the Cin in Fig.2
Refer to the Cout in Fig.2
C0
C1
C2
CY1、CY2
1000pF/400VAC
LCM1
LCM
2
3
CY
Fig. 4 Parameter description:
+Vin
-Vin
+Vo
0V
Vin
CY1
C4
C0
100µF/200V
0.22µF/250V
+
LOAD
DC/DC
C3
C0
C1
C2
CY2
C1、C2
C3
GND
4
CY
①
②
Refer to the Cin in Fig.2
LCM1
2.2mH(FL2D-10-222)
1.1mH
(material:TN150P-RH12.7*12.7*7.9)
Fig. 4
Notes: Part ① in the Fig. 4 is used for EMS test and part ② for EMI filtering;
LCM2
selected based on needs.
CY1、CY2、CY3、CY4
1000pF/400VAC
C4
Refer to the Cout in Fig.2
Notes: FL2D-10-222 is the EMC auxiliary component of our
company.
3. It is not allowed to connect modules output in parallel to enlarge the power
4. For more information about Mornsun EMC Filter products, please visit www.mornsun-power.com to
download the Selection Guide of EMC Filter
2016.11.07-A/0
Page 4 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-10WR3 Series
Horizontal Package (without heat sink) Dimensions and Recommended Layout
Horizontal Package (with heat sink) Dimensions
2016.11.07-A/0
Page 5 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-10WR3 Series
URB_LMD-10WR3A2S (without heat sink) Dimensions
URB_LMD-10WHR3A2S (with heat sink) Dimensions
2016.11.07-A/0
Page 6 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-10WR3 Series
URB_LMD-10WR3A4S (without heat sink) Dimensions
URB_LMD-10WHR3A4S(with heat sink) Dimensions
2016.11.07-A/0
Page 7 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URB1D_LMD-10WR3 Series
Note:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com.The
Packing bag number of Horizontal package :58200035(without heat sink), 58200051(with heat sink), A2S/ A4S package number:
58220022;
2. The maximum capacitive load offered were tested at input voltage range and full load;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25℃, humidity<75%RH with nominal
input voltage and rated output load;
4. All index testing methods in this datasheet are based on Company’s corporate standards;
5. Other product application information, please see DC-DC(railway power supply)Converter Application Notes for specific operation
methods;
6. We can provide product customization service, please contact our technicians directly for specific information;
7. Specifications are subject to change without prior notice.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: info@mornsun.cn
2016.11.07-A/0
Page 8 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
相关型号:
©2020 ICPDF网 联系我们和版权申明