URB2415MT-3WR3 [MORNSUN]

DC-DC Regulated Power Supply Module, 1 Output, 3W, Hybrid, PACKAGE-14/7;
URB2415MT-3WR3
型号: URB2415MT-3WR3
厂家: MORNSUN SCIENCE& TECHNOLOGY LTD.    MORNSUN SCIENCE& TECHNOLOGY LTD.
描述:

DC-DC Regulated Power Supply Module, 1 Output, 3W, Hybrid, PACKAGE-14/7

光电二极管
文件: 总5页 (文件大小:1205K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC/DC Converter  
URB_MT-3WR3 Series  
3W, Ultra wide input isolated & regulated  
single output DC/DC converter  
FEATURES  
Ultra wide input voltage rang (4:1)  
High efficiency up to 84%  
No-load power consumption as low as 0.10W  
Isolation voltage:1.5K VDC  
Input Under-voltage Protection, output  
short-circuit protection , over-current protection  
Operating temperature range: -40to +85℃  
International standard pin-out  
IEC60950 , UL60950 , EN60950 approval  
CB Patent Protection RoHS  
URB_MT-3WR3 series products are of 3W output power, extremely wide range of voltage input of 9-36VDC, 18-75VDC, isolation voltage of  
1500VDC, Input Under-voltage Protection, output short circuit protection, over-current protection, these products are widely used in fields  
such as industrial control, electric power, instruments and communication.  
Selection Guide  
Input Voltage (VDC)  
Nominal  
(Range)  
Output  
Efficiency  
(%, Min./Typ.)  
@ Full Load  
Max.  
Capacitive  
Load(µF)  
Certification  
Part No.  
Output Voltage Output Current (mA)  
Max.  
40  
(Max./Min.)  
(VDC)  
--  
UL /CE/ CB  
--  
URB2403MT-3WR3  
URB2405MT-3WR3  
URB2409MT-3WR3  
URB2412MT-3WR3  
3.3  
5
728/0  
600/0  
333/0  
250/0  
73/75  
78/80  
78/80  
80/82  
2200  
2200  
1000  
680  
24  
(9-36)  
9
12  
UL/ CE/ CB  
URB2415MT-3WR3  
URB2424MT-3WR3  
URB4803MT-3WR3  
15  
24  
3.3  
200/0  
125/0  
728/0  
81/83  
80/82  
73/75  
470  
100  
2200  
URB4805MT-3WR3  
URB4812MT-3WR3  
URB4815MT-3WR3  
URB4824MT-3WR3  
5
600/0  
250/0  
200/0  
125/0  
77/79  
80/82  
82/84  
80/82  
2200  
680  
470  
100  
48  
(18-75)  
12  
15  
24  
CE  
80  
Notes:  
Exceeding the maximum input voltage may cause permanent damage;  
The efficiency value is measured in the input nominal voltage and output rated load.  
Input Specifications  
Item  
Operating Conditions  
Min.  
Typ.  
Max.  
Unit  
mA  
3.3V Output  
Others  
--  
--  
--  
--  
134/4  
154/4  
67/4  
138/7  
161/7  
69/7  
24VDC input series nominal  
input voltage  
Input Current (full load / no-load)  
3.3V Output  
Others  
48VDC input series nominal  
input voltage  
77/4  
82/7  
Nominal 24VDC input series  
Nominal 48VDC input series  
Nominal 24VDC input series  
Nominal 48VDC input series  
Nominal 24VDC input series  
Nominal 48VDC input series  
Nominal 24VDC input series  
Nominal 48VDC input series  
--  
--  
120  
60  
--  
--  
--  
Reflected Ripple Current  
Surge Voltage (1sec. max.)  
Starting Voltage  
-0.7  
-0.7  
--  
50  
100  
9
--  
--  
VDC  
ms  
--  
--  
18  
--  
6.5  
15.5  
5.5  
13  
Input under-voltage protection  
--  
Nominal input voltage & constant resistance  
load  
Starting Time  
Input Filter  
10  
--  
--  
C filter  
Ctrl pin floating or connected to TTL high  
Module turn-on  
level(3.5-12VDC)  
Ctrl*  
Module turn-off  
Ctrl pin connected to GND or low level(0-1.2VDC)  
--  
6
10  
Input current when switched off  
mA  
2016.09.30-A/4  
Page 1 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB_MT-3WR3 Series  
Hot Plug  
Unavailable  
Note: *The voltage of Ctrl pin is relative to input pin GND.  
Output Specifications  
Item  
Operating Conditions  
Min.  
--  
Typ.  
±1  
Max.  
±3  
Unit  
%
Output Voltage Accuracy  
Full load, the input voltage is from low voltage to  
high voltage  
Line Regulation  
--  
±0.2  
±0.5  
Load Regulation  
0%-100% load  
--  
--  
--  
--  
--  
--  
±0.5  
300  
±3  
±1  
500  
±5  
Transient Recovery Time  
Transient Response Deviation  
Temperature Coefficient  
Ripple & Noise*  
µs  
%
25% load step change, nominal input voltage  
Full load  
--  
±0.03  
120  
250  
%/  
20MHz bandwidth , 5%-100% load  
30  
mV p-p  
%Io  
Over-current Protection  
Short circuit Protection  
150  
Input voltage range  
Hiccup protection  
Note: *Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application Notes for specific operation.  
0%-5% load ripple&Noise is no more than 5%Vo.  
General Specifications  
Item  
Operating Conditions  
Input-output, with the test time of 1 minute and  
the leak current lower than 1mA  
Min.  
Typ.  
--  
Max.  
--  
Unit  
Insulation Voltage  
1500  
VDC  
Insulation Resistance  
Isolation Capacitance  
Operating Temperature  
Storage Temperature  
Casing Temperature Rise  
Input-output, insulation voltage 500VDC  
Input-output, 100KHz/0.1V  
see Fig. 1  
1000  
--  
--  
1000  
--  
--  
--  
M
Ω
pF  
-40  
-55  
--  
+85  
+125  
--  
--  
Ta=25  
, nominal input voltage, full load output  
+40  
Pin Welding Resistance  
Temperature  
Welding spot is 1.5mm away from the casing, 10  
seconds  
--  
--  
+300  
Storage Humidity  
Non-condensing  
5
--  
95  
%RH  
Peak temp.245, maximum duration time60s  
at 217.  
For actual application, please refer to IPC/JEDEC  
J-STD-020D.1.  
Reflow Soldering Temperature  
Vibration  
10-55Hz, 10G, 30 Min. along X, Y and Z  
Switching Frequency*  
MTBF  
PWM Mode  
--  
350  
--  
--  
--  
KHz  
MIL-HDBK-217F@25℃  
1000  
K hours  
Note:*This series of products using lower frequency technology, the switching frequency value is the test value in full load, when the load is reduced to 50% or less  
the switching frequency decreases with decreasing load.  
Physical Specifications  
Casing Material  
Dimensions  
Black flame-retardant heat-proof plastic  
19.20*18.10*10.16 mm  
3.5g(Typ.)  
Weight  
Cooling Method  
Free air convection  
EMC Specifications  
CE  
CISPR22/EN55022 CLASS B (see Fig.3-  
for recommended circuit)  
EMI  
RE  
CISPR22/EN55022 CLASS B (see Fig.3-for recommended circuit)  
IEC/EN61000-4-2 Contact ±4KV  
IEC/EN61000-4-3 10V/m  
ESD  
RS  
perf. Criteria B  
perf. Criteria A  
perf. Criteria B  
perf. Criteria B  
perf. Criteria A  
EFT  
Surge  
CS  
IEC/EN61000-4-4 ±2KV (see Fig.3-for recommended circuit)  
IEC/EN61000-4-5 line to line ±2KV (see Fig.3-for recommended circuit)  
IEC/EN61000-4-6 3 Vr.m.s  
EMS  
Immunities of voltage dip, drop  
and short interruption  
IEC/EN61000-4-29 0%, 70%  
perf. Criteria B  
2016.09.30-A/4  
Page 2 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB_MT-3WR3 Series  
Product Characteristic Curve  
Temperature Derating Curve  
Safe Operating Area  
120  
100  
80  
60  
40  
20  
0
-40  
0
40  
71 85  
120  
Operating Temperature(  
)
Fig. 1  
Design Reference  
1. Typical application  
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.  
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or  
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product.  
Vn  
Cin  
Cout  
10µF  
+Vo  
Vin  
24VDC  
100µF  
Cout  
Cin  
DC  
DC  
48VDC  
10µF-47µF  
10µF  
GND  
0V  
Fig. 2  
2016.09.30-A/4  
Page 3 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB_MT-3WR3 Series  
2. EMC solution-recommended circuit  
Parameter description  
LDM1  
FUSE  
Vin  
+Vo  
0V  
Vin  
Model  
FUSE  
MOV  
C0  
Vin:24V  
Vin:48V  
+
Choose according to actual input current  
LOAD  
DC/DC  
C1  
C2  
C3  
MOV  
C0  
S20K30  
S14K60  
GND  
GND  
680µF/50V  
4.7µF/50V  
680µF/100V  
4.7µF/100V  
CY1  
C1,C2  
C3  
Refer to the Cout in Fig.2  
Fig. 3  
LDM1  
CY1  
12µH  
Notes: Part in the Fig. 3 is used for EMS test and part for EMI filtering;  
selected based on needs.  
1nF/2KV  
3. It is not allowed to connect modules output in parallel to enlarge the power  
4. For more information about Mornsun EMC Filter products, please visit www.mornsun-power.com to  
download the Selection Guide of EMC Filter  
Dimensions and Recommended Layout  
NC: Pin to be isolated from circuitry  
2016.09.30-A/4  
Page 4 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URB_MT-3WR3 Series  
Notes:  
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Tube  
Packing Bag Number : 58010114, Reel Packing Bag Number : 58010115 ;  
2. The max. capacitive load should be tested within the input voltage range and under full load conditions;  
3. If the product needs to be cleaned after welding, please wait to completely dried before electrical use it;  
4. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75%RH with nominal  
input voltage and rated output load;  
5. All index testing methods in this datasheet are based on our Company’s corporate standards;  
6. We can provide product customization service, please directly contact our technicians for specific information;  
7. Specifications of this product are subject to changes without prior notice.  
Mornsun Guangzhou Science & Technology Co., Ltd.  
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China  
Tel: 86-20-38601850-8801  
Fax: 86-20-38601272  
E-mail: info@mornsun.cn  
2016.09.30-A/4  
Page 5 of 5  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  

相关型号:

URB2415S-10WR3

10W, Ultra wide input, isolated & regulated single output, SIP package, DC-DC converter
MORNSUN

URB2415S-6WR3

6W, Ultra wide input, isolated & regulated single output, SIP package, DC-DC converter
MORNSUN

URB2415YMD-10WR3

DC/DC Converter
MORNSUN

URB2415YMD-15WR3

15W isolated DC-DC converter DIP package with Ultra-wide Input and Regulated Single Output
MORNSUN

URB2415YMD-20W

REGULATED SINGLE OUTPUT DIP PACKAGING, DC-DC CONVERTER
MORNSUN

URB2415YMD-20WR3

20W isolated DC-DC converter DIP package with Ultra-wide Input and Regulated Single Output
MORNSUN

URB2415YMD-6WR2

REGULATED DUAL/SINGLE OUTPUT DIP PACKAGING, DC-DC CONVERTER
MORNSUN

URB2415YMD-6WR3

DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, PACKAGE-5/4
MORNSUN

URB2415ZP-10WR3

10W, Ultra wide input, isolated & regulated dual/ single output, DIP package, DC-DC converter
MORNSUN

URB2415ZP-6WR2

DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, ROHS COMPLIANT, PACKAGE-7
MORNSUN

URB2424D-5W

DUAL/SINGLE OUTPUT DC-DC CONVERTER
MORNSUN

URB2424LD-15WHR2

Analog Circuit
MORNSUN