URB4803LD-30WHR3A4S [MORNSUN]

DC-DC Regulated Power Supply Module;
URB4803LD-30WHR3A4S
型号: URB4803LD-30WHR3A4S
厂家: MORNSUN SCIENCE& TECHNOLOGY LTD.    MORNSUN SCIENCE& TECHNOLOGY LTD.
描述:

DC-DC Regulated Power Supply Module

文件: 总9页 (文件大小:7181K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC/DC Converter  
URA_LD-30WR3 & URB_LD-30WR3 Series  
30W,Ultra wide input isolated & regulated dual/  
single output DC/DC converter  
FEATURES  
Ultra wide input voltage range (4:1)  
High efficiency up to 90% with full load  
High efficiency up to 82% with 5% load  
No-load power consumption as low as 0.14W  
Isolation voltage :1.5K VDC  
Input under-voltage protection, output short  
circuit, over-voltage, over-current protection  
Operating temperature range: -40to +80℃  
Meet CISPR22/EN55022 CLASS A, without  
external components  
Six-sided metal shielding package  
Reverse voltage protection available with  
A2S(Chassis mounting) or A4S(35mm DIN-Rail  
mounting)  
IEC60950, UL60950, EN60950 approval  
CB Patent Protection RoHS  
URA_LD-30WR3 & URB_LD-30WR3 series are isolated 30W DC-DC products with 4:1 input voltage. They feature efficiency up to 90%, 1500VDC  
isolation, operating temperature of -40~+80, Input under-voltage protection, output short circuit protection, over-voltage protection,  
over-current protection and EMI meets CISPR22/EN55022 CLASS A, which make them widely applied in data transmission device, battery  
power supply device, tele-comunication device, distributed power supply system, remote control system, industrial robot fields. And  
extension package A2S and A4S also enable them with reverse voltage protection.  
Selection Guide  
Input Voltage (VDC)  
Output  
Output Current  
Efficiency  
(%,Min./Typ.)  
@ Full Load  
Max.  
Capacitive  
Load(µF)  
Part No.  
Certification  
Nominal  
Output Voltage  
(VDC)  
Max.  
(mA)(Max./Min.)  
(Range)  
URB2403LD-30WR3  
3.3  
6000/0  
83/85  
86/88  
10000  
URB2405LD-30WR3  
URB2409LD-30WR3  
URB2412LD-30WR3  
URB2415LD-30WR3  
URB2424LD-30WR3  
URA2405LD-30WR3  
URA2412LD-30WR3  
URA2415LD-30WR3  
URA2424LD-30WR3  
URB4803LD-30WR3  
URB4805LD-30WR3  
URB4812LD-30WR3  
URB4815LD-30WR3  
URB4824LD-30WR3  
URA4805LD-30WR3  
URA4812LD-30WR3  
URA4815LD-30WR3  
5
9
6000/0  
3333/0  
2500/0  
2000/0  
1250/0  
±3000/0  
±1250/0  
±1000/0  
±625/0  
6000/0  
6000/0  
2500/0  
2000/0  
1250/0  
±3000/0  
±1250/0  
±1000/0  
10000  
4700  
2700  
1680  
680  
86/88  
88/90  
CB /UL/CE  
12  
88/90  
88/90  
15  
24  
(9-36)  
40  
24  
±5  
±12  
±15  
±24  
3.3  
5
84/86  
87/89  
87/89  
87/89  
84/86  
86/88  
86/88  
87/89  
87/89  
84/86  
86/88  
86/88  
2000  
1250  
680  
--  
470  
10000  
10000  
2700  
1680  
680  
12  
CB /UL/CE  
15  
48  
(18-75)  
80  
24  
±5  
±12  
±15  
2000  
1250  
680  
--  
Notes:①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mountingwith suffix “A4S” are DIN-Rail mounting, for example  
URB2405LD-30WHR3A2S is chassis mounting of with heat sink,URB2405LD-30WR3A4S is DIN-Rail mounting of without heat sink; If the application has a  
higher requirement for heat dissipation, you can choose modules with heat sink;  
Exceeding the maximum input voltage may cause permanent damage;  
Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection,  
minimum efficiency greater than Min.-2 is qualified.  
2016.07.07-A/4  
Page 1 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URA_LD-30WR3 & URB_LD-30WR3 Series  
Input Specifications  
Item  
Operating Conditions  
24VDC input  
Min.  
--  
Typ.  
970/60  
1420/60  
1388/6  
474/20  
710/20  
702/5  
40  
Max.  
993/100  
1453/100  
1488/12  
485/30  
726/35  
744/10  
--  
Unit  
mA  
3.3V output  
5V output  
Others  
--  
--  
Input Current (full load / no-load)  
3.3V output  
5V output  
Others  
--  
48VDC input  
--  
--  
Reflected Ripple Current  
Surge Voltage (1sec. max.)  
--  
24VDC input  
48VDC input  
24VDC input  
48VDC input  
24VDC input  
48VDC input  
-0.7  
-0.7  
--  
--  
50  
--  
100  
--  
9
Starting Voltage  
VDC  
ms  
--  
--  
18  
6.5  
5.5  
14.0  
--  
Under Voltage Shutdown  
Starting Time  
15.5  
--  
Nominal input voltage &  
constant resistance load  
10  
--  
--  
Input Filter  
Hot Plug  
Pi filter  
Unavailable  
Ctrl suspended or connected to TTL high level  
Module switch on  
(3.5-12VDC)  
Ctrl *  
Module switch off  
Ctrl pin connected to GND or low level (0-1.2VDC)  
Input current when switched off  
--  
5
8
mA  
Note: *The voltage of Ctrl pin is relative to input pin GND.  
Output Specifications  
Item  
Operating Conditions  
Min.  
--  
Typ.  
±1  
Max.  
Unit  
5%-100% load  
0%-5% load  
±3  
±5  
Output Voltage Accuracy  
--  
±1  
Positive Output  
--  
--  
--  
--  
±0.2  
±0.5  
±0.5  
±0.5  
±0.5  
±1  
Full load, the input voltage is  
from low voltage to high voltage  
Line Regulation  
Negative Output  
Positive Output  
Negative Output  
%
±1  
Load Regulation  
5%-100% load  
±1.5  
Dual output, main output 50% load,  
Supplement output from 10% to 100% load  
Cross Regulation  
--  
--  
±5  
Transient Recovery Time  
--  
--  
--  
--  
--  
--  
--  
300  
±5  
500  
±8  
µs  
%
25% load step change,  
3.3V/5V/±5V output  
nominal input voltage  
Transient Response Deviation  
Temperature Coefficient  
Others  
±3  
±5  
Full load  
--  
±0.03  
100  
%/  
50  
Singe output  
Dual output  
20MHz bandwidth, nominal input voltage,  
100% load  
Ripple & Noise  
Mv p-p  
50  
150  
--  
Trim  
±10  
%Vo  
%Io  
Over-voltage Protection  
Over-current Protection  
Short circuit Protection  
110  
110  
--  
--  
160  
190  
Input voltage range  
Hiccup, Continuous, self-recovery  
Note: When testing from 0% to100%load working conditions, load regulation index of ±5%;  
Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application Notes for specific operation.  
2016.07.07-A/4  
Page 2 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URA_LD-30WR3 & URB_LD-30WR3 Series  
General Specifications  
Item  
Operating Conditions  
Min.  
Typ.  
--  
Max.  
--  
Unit  
Input-output, with the test time of 1 minute and the  
leak current lower than 1mA  
Insulation Voltage  
1500  
VDC  
Input-output, insulation voltage 500VDC/60sec.,  
Ta=25, humidity=75%RH  
MΩ  
Insulation Resistance  
1000  
--  
--  
--  
--  
Isolation Capacitance  
Operating Temperature  
Storage Temperature  
Storage Humidity  
Input-output, 100KHz/0.1V  
2000  
pF  
see Fig. 1, Fig. 2, Fig. 3 and Fig. 4  
-40  
-55  
+5  
--  
--  
+80  
+125  
+95  
Non-condensing  
--  
%RH  
Pin Welding Resistance  
Temperature  
Welding spot is 1.5mm away from the casing, 10  
seconds  
--  
--  
+300  
Vibration  
10-55Hz, 10G, 30 Min. along X, Y and Z  
Switching Frequency *  
PWM mode  
--  
300  
--  
--  
--  
KHz  
MIL-HDBK-217F@25, Full load(Ground, Benign,  
controlled environment)  
MTBF  
1000  
K hours  
Note:* This series of products using reduced frequency technology, the switching frequency is test value of full load,When the load is reduced to below 50%, the  
switching frequency decreases with decreasing load.  
Physical Specifications  
Casing Material  
Aluminum alloy  
Horizontal package( without heat sink)  
Horizontal package( with heat sink)  
A2S wiring package ( without heat sink)  
A2S wiring package( with heat sink)  
A4S rail package( without heat sink)  
A4S rail package( with heat sink)  
50.80*25.40*11.80 mm  
50.80*25.40*16.30 mm  
76.00*31.50*21.20 mm  
76.00*31.50*25.10 mm  
76.00*31.50*25.80 mm  
76.00*31.50*29.70 mm  
26g/48g/68g(Typ.)  
Package Dimensions  
without heat sink  
with heat sink  
Horizontal package/A2S wiring package/A4S rail package  
Horizontal package/A2S wiring package/A4S rail package  
Weight  
34g/56g/76g(Typ.)  
Cooling Method  
Free air convection  
EMC Specifications  
for recommended circuit)  
for recommended circuit)  
for recommended circuit)  
CISPR22/EN55022 CLASS A (Bare component)/ CLASS B (see Fig.7-  
for recommended circuit)  
Single output CISPR22/EN55022 CLASS A (Bare component)/ CLASS B (see Fig.6-  
Dual output  
CISPR22/EN55022 CLASS A (Bare component)/ CLASS B (see Fig.7-  
Single output CISPR22/EN55022 CLASS A (Bare component)/ CLASS B (see Fig.6-  
CE  
EMI  
RE  
Dual output  
ESD  
RS  
IEC/EN61000-4-2  
IEC/EN61000-4-3  
IEC/EN61000-4-4  
IEC/EN61000-4-4  
IEC/EN61000-4-5  
IEC/EN61000-4-5  
Contact ±4KV  
perf. Criteria B  
10V/m  
perf. Criteria A  
perf. Criteria B  
perf. Criteria B  
perf. Criteria B  
perf. Criteria B  
perf. Criteria A  
perf. Criteria A  
±2KV (see Fig.6-for recommended circuit)  
±2KV (see Fig.7-for recommended circuit)  
line to line ±2KV (see Fig.6-for recommended circuit)  
line to line ±2KV (see Fig.7-for recommended circuit)  
3 Vr.m.s  
Single output  
Dual output  
Single output  
Dual output  
EFT  
EMS  
Surge  
CS  
Single output IEC/EN61000-4-6  
Dual output IEC/EN61000-4-6  
10Vr.m.s  
2016.07.07-A/4  
Page 3 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URA_LD-30WR3 & URB_LD-30WR3 Series  
Product Characteristic Curve  
Fig. 2  
Apply modelURA2405LD-30W(H)R318-36V input voltage、  
URA2424LD-30W(H)R318-36V input voltage、  
URA4805LD-30W(H)R336-75V input voltage、  
URA2412LD-30W(H)R3URA2415LD-30W(H)R3、  
URA4812LD-30W(H)R3URA4815LD-30W(H)R3  
Fig. 1  
Apply modelURA2405LD-30W(H)R3 9-18V input voltage、  
URA2424LD-30W(H)R3 9-18V input voltage、  
URA4805LD-30W(H)R318-36V input voltage)  
Fig. 4  
Fig. 3  
Apply modelURB2409LD-30W(H)R3URB2412LD-30W(H)R3、  
URB2415LD-30W(H)R3URB2424LD-30W(H)R3、  
URB4812LD-30W(H)R3URB4815LD-30W(H)R3、  
URB4824LD-30sW(H)R3  
Apply modelURB2403LD-30W(H)R3URB2405LD-30W(H)R3、  
URB4803LD-30W(H)R3URB4805LD-30W(H)R3  
Efficiency Vs Input (Full Load)  
100  
95  
90  
85  
80  
75  
70  
URB2405LD-  
30WR3  
9
12 15 18 21 24 27 30 33 36  
Input Voltage (V)  
2016.07.07-A/4  
Page 4 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URA_LD-30WR3 & URB_LD-30WR3 Series  
Design Reference  
1. Typical application  
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 5) before delivery.  
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or  
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product.  
Dual output:  
+Vo  
Vin  
Cout  
Cout  
Single output  
voltage  
Dual output  
voltage  
Cout  
(µF)  
Cin  
(µF)  
Cout  
(µF)  
Cin  
(µF)  
Cin  
0V  
DC DC  
(VDC)  
(VDC)  
GND  
-Vo  
Single output:  
Vin  
3.3/5/9  
220  
100  
±5/±12/±15  
±24  
220  
100  
100  
100  
+Vo  
0V  
12/15/24  
Cin  
Cout  
DC DC  
Fig. 5  
GND  
2. EMC solution-recommended circuit  
Parameter description  
Single output  
Model  
FUSE  
Vin:24V  
Vin:48V  
Choose according to actual input  
current  
CY  
1
LCM  
FUSE  
Vin  
Vin  
+Vo  
0V  
C3  
+
+
LOAD  
MOV  
S20K30  
S14K60  
DC/DC  
C2  
C1  
C0  
MOV  
C0  
C1  
C2  
C3  
680µF/50V  
330µF/50V  
4.7µF/50V  
330µF/100V  
330µF/100V  
2.2µF/100V  
GND  
GND  
2
CY  
Fig. 6  
Refer to the Cout in Fig.5  
1mH, recommended to use  
MORNSUN’s FL2D-30-102s  
Notes: Part in the Fig. 6 is used for EMS test and part for EMI filtering;  
LCM  
selected based on needs.  
CY1CY2  
1nF/2KV  
Model  
FUSE  
Vin:24V  
Vin:48V  
Choose according to actual input  
current  
Dual output  
CY  
1
FUSE  
MOV  
C0  
S20K30  
S14K60  
Vin  
Vin  
+Vo  
-V0  
680µF/50V  
2.2µF/50V  
2.2µF/50V  
330µF/50V  
330µF/100V  
2.2µF/100V  
2.2µF/100V  
330µF/100V  
C4  
+
+
C3  
LOAD  
DC/DC  
C2  
C0  
C1  
MOV  
C1  
GND  
GND  
LDM1  
C2  
2
CY  
C3  
Fig.7  
C4  
Refer to the Cout in Fig.5  
3.3µH  
Notes: Part in the Fig. 7 is used for EMS test and part for EMI filtering;  
LDM1  
CY1CY2  
selected based on needs.  
2.2nF/400VAC Safety Y Capacitor  
2016.07.07-A/4  
Page 5 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URA_LD-30WR3 & URB_LD-30WR3 Series  
3. Application of Trim and calculation of Trim resistance  
Vo’  
Vo’  
Calculation formula of Trim resistance:  
aR2  
R2-a  
Vref  
Vo’-Vref  
R
1
-R3  
-R3  
up:  
RT=  
RT=  
a=  
a=  
R1  
R2  
R
T
R
1
R
3
V
ref  
Trim  
R
3
V
ref  
aR1  
R1-a  
Trim  
Vo’-Vref  
Vref  
down:  
R
2
R
T
R
2
RT is Trim resistance ,a is a self-defined  
parameter, with no real meaning.  
Vo’ for the actual needs of the up or  
down regulated voltage  
0V  
Trim down  
0V  
Trim up  
Applied circuits of Trim (Part in broken line is the interior of models)  
R1(KΩ)  
4.801  
R2(KΩ)  
2.87  
R3(KΩ)  
12.4  
10  
Vout(VDC)  
Vref(V)  
1.24  
2.5  
3.3  
5
2.883  
2.87  
9
7.500  
2.87  
15  
2.5  
12  
15  
24  
11.000  
14.494  
24.872  
2.87  
15  
2.5  
2.87  
15  
2.5  
2.87  
17.8  
2.5  
4. It is not allowed to connect modules output in parallel to enlarge the power  
5. For more information please find DC-DC converter application notes on www.mornsun-power.com  
Horizontal Package (without heat sink) Dimensions and Recommended Layout  
2016.07.07-A/4  
Page 6 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URA_LD-30WR3 & URB_LD-30WR3 Series  
Horizontal Package (with heat sink) Dimensions  
URA_LD-30WR3A2S & URB_LD-30WR3A2S(without heat sink) Dimensions  
2016.07.07-A/4  
Page 7 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URA_LD-30WR3 & URB_LD-30WR3 Series  
URA_LD-30WR3A2S & URB_LD-30WR3A2S(with heat sink) Dimensions  
URA_LD-30WR3A4S & URB_LD-30WR3A4S(without heat sink) Dimensions  
2016.07.07-A/4  
Page 8 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URA_LD-30WR3 & URB_LD-30WR3 Series  
URA_LD-30WR3A4S & URB_LD-30WR3A4S(with heat sink) Dimensions  
Notes:  
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com.  
Horizontal Packing Bag Number: 58200035(without heat sink), 58200051(with heat sink), A2S/A4S Packing Bag Number: 58220022;  
2. The maximum capacitive load offered were tested at input voltage range and full load;  
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75%RH with nominal  
input voltage and rated output load;  
4. All index testing methods in this datasheet are based on Company’s corporate standards;  
5. We can provide product customization service, please contact our technicians directly for specific information;  
6. Specifications are subject to change without prior notice.  
Mornsun Guangzhou Science & Technology Co., Ltd.  
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China  
Tel: 86-20-38601850-8801  
Fax: 86-20-38601272  
E-mail: info@mornsun.cn  
2016.07.07-A/4  
Page 9 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  

相关型号:

URB4803LD-30WR3

DC-DC Regulated Power Supply Module, 1 Output, 19.8W, Hybrid, PACKAGE-6
MORNSUN

URB4803MP-12W

SINGLE OUTPUT DC-DC CONVERTER
MORNSUN

URB4803MT-3WR3

DC-DC Regulated Power Supply Module, 1 Output, 2.4024W, Hybrid, PACKAGE-14/7
MORNSUN

URB4803YMD-10WR3

DC/DC Converter
MORNSUN

URB4803YMD-15WR3

15W isolated DC-DC converter DIP package with Ultra-wide Input and Regulated Single Output
MORNSUN

URB4803YMD-20W

REGULATED SINGLE OUTPUT DIP PACKAGING, DC-DC CONVERTER
MORNSUN

URB4803YMD-20WR3

20W isolated DC-DC converter DIP package with Ultra-wide Input and Regulated Single Output
MORNSUN

URB4803YMD-6WR2

REGULATED DUAL/SINGLE OUTPUT DIP PACKAGING, DC-DC CONVERTER
MORNSUN

URB4803YMD-6WR3

DC-DC Regulated Power Supply Module, 1 Output, 4.95W, Hybrid, PACKAGE-5/4
MORNSUN

URB4803ZP-10WR3

10W, Ultra wide input, isolated & regulated dual/ single output, DIP package, DC-DC converter
MORNSUN

URB4803ZP-6WR2

DC-DC Regulated Power Supply Module, 1 Output, 4.95W, Hybrid, ROHS COMPLIANT, PACKAGE-7
MORNSUN

URB4803ZP-6WR3

DC-DC Regulated Power Supply Module, 1 Output, 4.95W, Hybrid, DIP-24/7
MORNSUN