URB4812ZP-6WR2 [MORNSUN]
DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, ROHS COMPLIANT, PACKAGE-7;型号: | URB4812ZP-6WR2 |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, ROHS COMPLIANT, PACKAGE-7 |
文件: | 总5页 (文件大小:242K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC/DC Converter
URA_ZP-6WR2 & URB_ZP-6WR2 Series
6W, ultra-wide input isolated & regulated
dual / single output
FEATURES
z
z
z
z
z
z
z
z
z
Wide range of input voltage (4:1)
Efficiency up to 88%
Isolation voltage :1500VDC
Operating temperature range: -40℃ to +85℃
Output short circuit protection
Output over voltage protection
International standard pin-out
Low ripple & noise
Patent Protection RoHS
Meet CISPR22/EN55022 CLASS A
URA_ZP-6WR2 & URB_ZP-6WR2 series products are of 6W output power, ultra-wide range of voltage input of 9-36VDC, 18-75VDC, isolation
voltage of 1500VDC, output over-voltage protection and output short circuit protection with the six-sided metal shielding package; these
products are widely used in fields such as industrial control, electric power, instruments and communication.
Selection Guide
Input Voltage (VDC)
Nominal
(Range)
Output
Efficiency
(%,Min./Typ.)
@ Full Load
Max. Capacitive
Part No.
②
Output Voltage
(VDC)
Output Current
①
Load (μF)
Max.
(mA)(Max./Min.)
±600/±30
±250/±12
±200/±10
±125/±6.25
1500/75
1200/60
500/25
81/83
85/87
85/87
85/87
77/79
81/83
85/87
86/88
85/87
81/83
85/87
86/88
78/80
82/84
85/87
86/88
85/87
470
100
100
47
URA2405ZP-6WR2
URA2412ZP-6WR2
URA2415ZP-6WR2
URA2424ZP-6WR2
URB2403ZP-6WR2
URB2405ZP-6WR2
URB2412ZP-6WR2
URB2415ZP-6WR2
URB2424ZP-6WR2
URA4805ZP-6WR2
URA4812ZP-6WR2
URA4815ZP-6WR2
URB4803ZP-6WR2
URB4805ZP-6WR2
URB4812ZP-6WR2
URB4815ZP-6WR2
URB4824ZP-6WR2
±5
±12
±15
±24
3.3
5
24
(9-36)
1800
1000
100
100
47
40
12
15
400/20
24
250/12
470
100
100
1800
1000
100
100
47
±5
±12
±15
3.3
5
±600/±30
±250/±12
±200/±10
1500/75
1200/60
500/25
48
(18-75)
80
12
15
400/20
24
250/12
Note:①Absolute maximum rating without damage on the converter, but it isn't recommended;
②The capacitive loads of positive and negative outputs are identical.
Input Specifications
Item
Operating Conditions
Min.
--
Typ.
Max.
Unit
mA
24VDC input
48VDC input
24VDC/48VDC input
24VDC input
48VDC input
24VDC input
48VDC input
301/7
149/3
20
--
--
Input Current (full load / no-load)
Reflected Ripple Current
Input impulse Voltage (1sec. max.)
--
--
--
-0.7
-0.7
--
--
50
100
VDC
--
--
--
--
9
Starting Voltage
Input Filter
18
TT filter
2014.10.30-A/2
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_ZP-6WR2 & URB_ZP-6WR2 Series
Output Specifications
Item
Operating Conditions
5%-100% load
Min.
--
Typ.
±1
Max.
±2
Unit
%
Output Voltage Accuracy
Output Voltage Balance
Dual output, balance load
--
±0.5
±1.5
Full load, the input voltage is
from low voltage to high
voltage
Main load
--
±0.2
±0.5
Line Regulation
Supplement load
--
--
--
--
±0.5
--
±1.0
±1
Load Regulation
Cross Regulation
5%-100% load
Dual output, main output 50% load,
Supplement output from 10% to 100% load
±5
Transient Recovery Time
--
--
--
--
μs
%
300
±3
--
500
±5
25% load step change
Transient Response Deviation
Temperature Drift Coefficient
%/℃
Full load
±0.03
25
*
20MHz bandwidth
10
Ripple
3.3V, 5V output
mV p-p
%Vo
--
--
30
50
--
80
Noise*
20MHz bandwidth
others
100
140
Output Over-voltage Protection
Output Short circuit Protection
110
Input voltage range
Hiccup, continuous, self-recovery
Note:* Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods.
General Specifications
Item
Operating Conditions
Min.
Typ.
--
Max.
--
Unit
Input-output, with the test time of 1 minute
and the leak current lower than 1mA
Isolation Voltage
1500
VDC
Isolation Resistance
Isolation Capacitance
Operating Temperature
Storage Temperature
Storage Humidity
Input-output, insulation voltage 500VDC
Input-output, 100KHz/0.1V
see Fig. 1
1000
--
--
1000
--
--
--
MΩ
pF
-40
-55
5
85
℃
--
125
95
Non-condensing
--
%RH
Max. Operating Temperature for casing Within the operating temperature curve
--
--
105
℃
Welding spot is 1.5mm away from the
casing, 10 seconds
Pin Welding Resistance Temperature
--
--
300
--
300
--
Switching Frequency
MTBF
PWM mode
--
KHz
MIL-HDBK-217F@25°C
1000
--
K hours
Physical Specifications
Casing Material
Package Dimensions
Weight
Aluminum alloy
32.00*20.00*10.80mm
14g (Typ.)
Cooling Method
Free air convection
EMC Specifications
CISPR22/EN55022 CLASS A (Bare component)/ CLASS B (see Fig.3-② for recommended circuit)
CISPR22/EN55022 CLASS A(Bare component)/ CLASS B (see Fig.3-② for recommended circuit)
Conducted disturbance
EMI
Radiated emission
Electrostatic discharge
Radiation immunity
EFT
IEC/EN61000-4-2
IEC/EN61000-4-3
IEC/EN61000-4-4
IEC/EN61000-4-5
Contact ±4KV
perf. Criteria B
perf. Criteria A
perf. Criteria B
perf. Criteria B
perf. Criteria A
10V/m
±2KV (see Fig.3-① for recommended circuit)
±2KV (see Fig.3-①for recommended circuit)
3 Vr.m.s
EMS
Surge immunity
Conducted disturbance immunity IEC/EN61000-4-6
Immunities of voltage dip,
drop and short interruption
IEC/EN61000-4-29 0-70%
perf. Criteria B
2014.10.30-A/2
Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_ZP-6WR2 & URB_ZP-6WR2 Series
Product Characteristic Curve
Temperature Derating Curve
Safe Operating Area
120
100
80
60
40
20
0
-40
0
40
71 85
120
)
℃
Operating Temperature(
Fig. 1
Efficiency Vs Input Voltage (Full Load)
Efficiency Vs Output Load(Vin=Vin-nominal)
100
95
90
85
80
75
70
65
60
55
50
100
90
80
70
60
50
40
30
20
10
0
URB4815ZP-
6WR2
URB4815ZP-
6WR2
5
10 20 30 40 50 60 70 80 90 100
Output Current Percentage (%)
18 24 30 36 42 48 54 60 66 72 75
Input Voltage (V)
Design Reference
1. Typical application
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product.
Dual Output
+Vo
Vin
Cout
0V
Cin
DC
DC
DC
DC
Cout
GND
Vin(VDC)
12
Cin(μF)
100
Cout(μF)
-Vo
Single Output
Vin
10
+Vo
0V
24/48
10~47
Cout
Cin
GND
Fig. 2
2. EMC solution-recommended circuit
Parameter description
Model
CY1
LDM1
FUSE
V in
+Vo
Vin
Vin:24V
Vin:48V
+
FUSE
MOV
C0
Choose according to actual input current
LOAD
DC/DC
C0
C1
C2
MOV
S14K35
330μF/50V
1μF/50V
S14K60
330μF/100V
1μF/100V
GND
0V
GND
①
②
2
CY
C1
C2
Refer to the Cout in Fig.2
Fig. 3
LDM1
CY1, CY2
4.7μH
Notes: Part ① in the Fig. 3 is used for EMS test and part ② for EMI filtering;
1nF/2KV
selected based on needs.
2014.10.30-A/2
Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_ZP-6WR2 & URB_ZP-6WR2 Series
EMC solution-recommended circuit PCB layout
Dual
Single
Fig. 4
Note: the min. distance of the bonding pads between input & output isolation capacitors (CY1/CY2) shall be ≥ 2mm.
3. The product does not support output in parallel with power per liter or hot-plug use
4. For more information please find the application notes on www.mornsun-power.com
Horizontal Package Dimensions and Recommended Layout (without heat sink)
2014.10.30-A/2
Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_ZP-6WR2 & URB_ZP-6WR2 Series
Notes:
1. Packing Information please refer to 'Product Packing Information'. The Packing bag number of Horizontal package :58210008 ;
2. Recommended used in more than 5% load, if the load is lower than 5%, then the ripple index of the product may exceed the
specification, but does not affect the reliability of the product;
3. The unbalance degree of the recommended dual output module load: ≤ 5%; if the degree exceeds ±5%, then the product
performances cannot be guaranteed to comply with all the performance indicators in the manual, and please directly contact our
technicians for specific information;
4. The max. capacitive load should be tested within the input voltage range and under full load conditions;
5. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25℃, humidity<75% when inputting
nominal voltage and outputting rated load;
6. All index testing methods in this datasheet are based on our Company’s corporate standards;
7. The performance indexes of the product models listed in this datasheet are as above, but some indexes of non-standard model
products will exceed the above-mentioned requirements, and please directly contact our technicians for specific information;
8. We can provide product customization service;
9. Specifications of this product are subject to changes without prior notice.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: info@mornsun.cn
2014.10.30-A/2
Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
相关型号:
©2020 ICPDF网 联系我们和版权申明