URD480524S-3WR3 [MORNSUN]

3W, Ultra wide input, dual isolated & regulated dual output, SIP package, DC-DC converter;
URD480524S-3WR3
型号: URD480524S-3WR3
厂家: MORNSUN SCIENCE& TECHNOLOGY LTD.    MORNSUN SCIENCE& TECHNOLOGY LTD.
描述:

3W, Ultra wide input, dual isolated & regulated dual output, SIP package, DC-DC converter

文件: 总4页 (文件大小:715K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC/DC Converter  
URD_S-3WR3 Series  
3W, Ultra wide input, dual isolated & regulated dual  
output, SIP package, DC-DC converter  
FEATURES  
Ultra wide input voltage range (4:1)  
No-load power consumption as low as 0.2W  
Isolation voltage : 3K VDC  
Input under-voltage protection, output short  
circuit, over-current protection  
Operating temperature range: -40to +85℃  
Meets EN62368 standards  
Patent Protection RoHS  
URD_S-3WR3 series are isolated 3W DC-DC products with 4:1 input voltage.3000VDC isolation, operating temperature of -40to +85, input  
under-voltage protection, over-current, short circuit protection and EMI meets CISPR32/EN55032 CLASS B, which make them widely applied  
in data transmission device, Tele-comunication device, distributed power supply system, remote control system, industrial robot system  
fields.  
Selection Guide  
Output  
Max. Capacitive  
Load (µF)  
Input Voltage (VDC)  
Efficiency  
(%,Min./Typ.)  
(Primary output/Secondary output)  
Certification  
Part No.  
(Primary  
Output  
Current (mA) Current (mA)  
Output  
Nominal  
(Range)  
Output Voltage  
(VDC)  
Max.  
@ Full Load output/Secondary  
output)  
(Max.)  
300/300  
300/125  
300/63  
(Min.)  
URD480505S-3WR3  
URD480512S-3WR3  
URD480524S-3WR3  
5/5  
0/0  
76/78  
76/78  
76/78  
680/680  
680/330  
680/220  
48  
80  
--  
5/12  
5/24  
0/0  
(18-75)  
0/0  
Notes  
Absolute maximum rating without damage on the converter, but it isn't recommended;  
Efficiency is measured In nominal input voltage and rated output load.  
Input Specifications  
Item  
Operating Conditions  
Nominal input voltage  
Nominal input voltage  
Min.  
Typ.  
Max.  
Unit  
Input Current  
(full load / no-load)  
--  
81/5  
83/12  
mA  
Reflected Ripple Current  
Surge Voltage (1sec. max.)  
Starting Voltage  
--  
-0.7  
--  
30  
--  
--  
100  
18  
--  
VDC  
ms  
--  
Input Under-voltage Protection  
Starting Time  
12  
--  
15  
10  
Nominal input& constant resistance load  
--  
Capacitance Filter  
Unavailable  
Input Filter  
Hot Plug  
Output Specifications  
Min.  
--  
Typ.  
±1  
Max.  
±3  
Unit  
Item  
Operating Conditions  
Primary Output  
10% -100% load  
5% -10% load  
Secondary Output  
Primary Output  
--  
±3  
±5  
Output Voltage Accuracy  
--  
±2  
±4  
Secondary Output  
Primary Output  
--  
±4  
±6  
--  
±0.2  
±0.5  
±0.5  
±1  
±0.5  
±1  
Full load, the input voltage is from low  
voltage to high voltage  
%
Line Regulation  
Secondary Output  
Primary Output  
--  
--  
±1  
Load Regulation  
10% -100% load  
Secondary Output  
--  
±2  
Main output 50% load,Supplement output from 25% to  
100% load  
Cross Regulation  
--  
--  
±8  
Transient Recovery Time  
--  
--  
--  
300  
±5  
--  
500  
±8  
µs  
%
25% load step change, nominal input voltage  
Full load  
Transient Response Deviation  
%/  
Temperature Coefficient  
±0.03  
2018.06.28-A/0  
Page 1 of 4  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URD_S-3WR3 Series  
Primary Output  
--  
--  
70  
100  
--  
150  
150  
250  
20MHz bandwidth,nominal input, full  
load  
Ripple & Noise  
mV p-p  
%Io  
Secondary Output  
Over-current Protection  
Short circuit Protection  
110  
Input voltage range  
Hiccup,continuous, self-recovery  
Note: When testing from 0% -100%load working conditionsload regulation index of ±5%;  
Dynamic load only for primary output.  
Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application Notes for specific operation;  
Dual output with balanced-load;  
Any short circuit,two lines of the output enter burping protection;main output need to on 10%-100% load,secondary output can be short-circuited;  
secondary output need to on 0%-100% load,primary output can be short-circuited  
General Specification  
Item  
Operating Conditions  
Min.  
3000  
1500  
1000  
--  
Typ.  
--  
Max.  
--  
Unit  
Input-output  
with the test time of 1 minute and  
the leak current lower than 1mA  
Insulation Voltage  
VDC  
output-output  
--  
--  
Input-output, insulation voltage 500VDC/min ,25  
Input-output, 100KHz/0.1V  
see Fig. 1  
,75%RH  
--  
--  
MΩ  
pF  
Insulation Resistance  
Isolation Capacitance  
Operating Temperature  
Storage Humidity  
1000  
--  
--  
-40  
+85  
95  
Without condensation  
5
--  
%RH  
Storage Temperature  
-55  
--  
+125  
Pin Welding Resistance  
Temperature  
Welding spot is 1.5mm away from the casing, 10 seconds  
--  
--  
+300  
Vibration  
10-150Hz, 5G, 0.75mm. along X, Y and Z  
Switching Frequency *  
MTBF  
PWM mode  
--  
300  
--  
--  
--  
KHz  
MIL-HDBK-217F@25,full load  
1000  
K hours  
Note:* This series of products using reduced frequency technology, the switching frequency is test value of full load,When the load is reduced to below 50%, the  
switching frequency decreases with decreasing load.  
Physical Specifications  
Casing Material  
Dimension  
Black flame-retardant and heat-resistant plastic (UL94 V-0)  
27.40*9.50*12.00mm  
Weight  
5.43  
Typ.)  
Cooling method  
Free air convection  
EMC Specifications  
CE  
CISPR32/EN55032  
CISPR32/EN55032  
IEC/EN61000-4-2  
IEC/EN61000-4-3  
IEC/EN61000-4-4  
IEC/EN61000-4-5  
IEC/EN61000-4-6  
CLASS B (see Fig.3-  
for recommended circuit)  
EMI  
CLASS B (see Fig.3-for recommended circuit)  
RE  
ESD  
RS  
Contact ±4KV  
10V/m  
perf. Criteria B  
perf. Criteria A  
perf. Criteria B  
perf. Criteria B  
perf. Criteria A  
EMS  
EFT  
±2KV (see Fig.3-  
for recommended circuit)  
line to line ±2KV (see Fig.3-for recommended circuit)  
Surge  
CS  
3 Vr.m.s  
Product Characteristic Curve  
Fig. 1  
2018.06.28-A/0  
Page 2 of 4  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URD_S-3WR3 Series  
Design Reference  
1. Typical application  
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.  
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or  
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitor load of the product.  
Output voltage(VDC)  
Cin(uF)  
47  
Cout(uF)  
100  
5
12  
24  
22  
22  
Fig. 2  
2. EMC solution-recommended circuit  
Fig. 3 Parameter description  
Model  
FUSE  
Vin:48V  
Choose according to actual input current  
C0  
680µF/100V  
4.7µF/100V  
C1/C5/C6  
C2  
330µF/100V  
C3/C4  
LDM1  
Refer to the Cout in Fig.2  
22µH/0.6A  
Fig. 3  
CY1/CY2/CY4  
CY3  
1nF/3kV  
Notes: Part in the Fig. 3 is used for EMI filtering and part for EMC test;  
selected based on needs.  
2.2nF/3kV  
3. It is not allowed to connect modules output in parallel to enlarge the power  
4. For more information please find dc-dc converter application notes on www.mornsun-power.com  
2018.06.28-A/0  
Page 3 of 4  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
URD_S-3WR3 Series  
Dimensions and Recommended Layout  
Note:  
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com.Packing  
bag number : 58210015;  
2. The maximum capacitor load offered were tested at input voltage range and full load;  
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75%RH with nominal  
input voltage and rated output load;  
4. All index testing methods in this datasheet are based on Company’s corporate standards;  
5. We can provide product customization service, please contact our technicians directly for specific information;  
6. Products are related to laws and regulations: see "Features" and "EMC";  
7. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by  
qualified units.  
Mornsun Guangzhou Science & Technology Co., Ltd.  
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China  
Tel: 86-20-38601850-8801  
Fax: 86-20-38601272  
E-mail: info@mornsun.cn  
2018.06.28-A/0  
Page 4 of 4  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  

相关型号:

URDK09G8914

Retroreflective Photoelectric Sensor, 0mm Min, 200mm Max, 100mA, Rectangular
IVO

URDK10N8914/KS35A

Retroreflective Photoelectric Sensor, 0mm Min, 200mm Max, 200mA, Rectangular, Board Mount
IVO

URDK10N8914/S35A

Retroreflective Photoelectric Sensor, 0mm Min, 200mm Max, 200mA, Rectangular, Board Mount
IVO

URDK10P8914/KS35A

Retroreflective Photoelectric Sensor, 0mm Min, 200mm Max, 200mA, Rectangular, Board Mount
IVO

URDK10P8914/S35A

Retroreflective Photoelectric Sensor, 0mm Min, 200mm Max, 200mA, Rectangular, Board Mount
IVO

URDK20N6903/S35A

Retroreflective Photoelectric Sensor, 0mm Min, 1000mm Max, 200mA, Rectangular, Board Mount
IVO

URDK20N6912/S35A

Retroreflective Photoelectric Sensor, 0mm Min, 400mm Max, 200mA, Rectangular, Board Mount
IVO

URDK20N7912/S35A

Retroreflective Photoelectric Sensor, 0mm Min, 400mm Max, 200mA, Rectangular, Board Mount
IVO

URDK20N7914/S35A

Retroreflective Photoelectric Sensor, 0mm Min, 200mm Max, 200mA, Rectangular, Board Mount
IVO

URDK20P6903/S35A

Retroreflective Photoelectric Sensor, 0mm Min, 1000mm Max, 200mA, Rectangular, Board Mount
IVO

URDK20P6912/S35A

Retroreflective Photoelectric Sensor, 0mm Min, 400mm Max, 200mA, Rectangular, Board Mount
IVO

URDK20P6914/S35A

Retroreflective Photoelectric Sensor, 0mm Min, 200mm Max, 200mA, Rectangular, Board Mount
IVO