VRA_LD-20WR3 & VRB_LD-20WR3 Series  
20W,wide input isolated & regulated dual /  
single output DC/DC converter  
FEATURES  
wide input voltage rang (2:1)  
High efficiency up to 90%  
No-load power consumption as low as 0.15W  
Isolation voltage :1.5KVDC  
output short circuit protection, over-voltage  
protection, over-current protection  
Operating temperature range: -40to +85℃  
Meet CISPR32/EN55032 CLASS A, without  
external components  
Six-sided metal shielding package  
Reverse voltage protection available with  
A2S(Chassis mounting) or A4S(35mm DIN-Rail  
mounting)  
EN60950 approval  
Patent Protection RoHS  
VRA_LD-20WR3 & VRB_LD-20WR3 series are isolated 20W DC-DC products with 2:1 input voltage. They feature efficiency up to 90%, 1500VDC  
isolation, operating temperature of -40to +85, output short circuit protection, over-voltage protection, over-current protection and EMI  
meets CISPR32/EN55032 CLASS A, without external components which make them widely applied in data transmission device, battery  
power supplies, Tele-comunication device, distributed power supply system, remote control system, industrial robot system fields. And  
extension package A2S and A4S also enable them with reverse voltage protection.  
Selection Guide  
Efficiency (%,Mi  
n./Typ.)  
@ Full Load  
Input Voltage (VDC)  
Output  
Output Current  
Max. Capacitive  
Certification  
Part No.  
Nominal  
Output Voltage  
(VDC)  
Load (µF)  
Max.  
(mA)(Max./Min.)  
(Range)  
12  
(9-18)  
--  
VRB121DLD-20WR3  
20  
110  
182/9  
86/88  
66  
VRA2405LD-20WR3  
VRA2409LD-20WR3  
VRA2412LD-20WR3  
VRA2415LD-20WR3  
VRA2424LD-20WR3  
VRB2403LD-20WR3  
VRB2405LD-20WR3  
VRB2409LD-20WR3  
VRB2412LD-20WR3  
VRB2415LD-20WR3  
VRB2424LD-20WR3  
VRA4805LD-20WR3  
VRA4812LD-20WR3  
VRA4815LD-20WR3  
VRB4803LD-20WR3  
VRB4805LD-20WR3  
VRB4809LD-20WR3  
VRB4812LD-20WR3  
VRB4815LD-20WR3  
VRB4824LD-20WR3  
±5  
±9  
±12  
±15  
±24  
3.3  
5
±2000/0  
±1111/0  
±834/0  
±667/0  
±417/0  
5000/0  
4000/0  
2222/0  
1667/0  
1333/0  
834/0  
84/86  
86/88  
86/88  
86/88  
86/88  
84/86  
88/90  
87/89  
87/89  
88/90  
88/90  
84/86  
86/88  
87/89  
84/86  
88/90  
87/89  
87/89  
88/90  
88/90  
4800  
1000  
800  
CE  
--  
625  
500  
24  
(18-36)  
40  
10000  
10000  
4700  
1600  
1000  
500  
9
12  
15  
24  
±5  
±12  
±15  
3.3  
5
±2000/0  
±834/0  
±667/0  
5000/0  
4000/0  
2222/0  
1667/0  
1333/0  
834/0  
4800  
800  
CE  
625  
10000  
10000  
4700  
1600  
1000  
500  
48  
(36-75)  
80  
9
12  
15  
24  
Notes:①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mountingwith suffix “A4S” are DIN-Rail mounting, for example  
VRB2405LD-20WHR3A2S is chassis mounting of with heat sink,VRB2405LD-20WR3A4S is DIN-Rail mounting of without heat sink; If the application has a  
higher requirement for heat dissipation, you can choose modules with heat sink;  
Absolute maximum rating without damage on the converter, but it isn't recommended;  
Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection,  
minimum efficiency greater than Min.-2 is qualified;  
The capacitive loads of positive and negative outputs are identical.  
2018.08.16-A/4  
Page 1 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
VRA_LD-20WR3 & VRB_LD-20WR3 Series  
Input Specifications  
Item  
Operating Conditions  
12VDC input  
Min.  
--  
Typ.  
1894/35  
799/40  
969/40  
947/6  
400/20  
485/20  
474/5  
20  
Max.  
1938/--  
818/45  
993/45  
969/10  
409/25  
497/25  
485/9  
--  
Unit  
mA  
3.3V output  
5V output  
Others  
--  
24VDC input  
48VDC input  
--  
Input Current (full load / no-load)  
--  
3.3V output  
5V output  
Others  
--  
--  
--  
12VDC input  
24VDC / 48VDC input  
12VDC input  
24VDC input  
48VDC input  
12VDC input  
24VDC input  
48VDC input  
--  
Reflected Ripple Current  
Surge Voltage (1sec. max.)  
--  
30  
--  
-0.7  
-0.7  
-0.7  
--  
--  
25  
--  
50  
--  
100  
VDC  
ms  
--  
9
Starting Voltage  
--  
--  
18  
--  
--  
36  
Starting Time  
Input Filter  
Nominal input voltage & constant resistance load  
--  
10  
--  
Pi filter  
Ctrl suspended or connected to TTL high  
Module switch on  
Module switch off  
level (3.5-12VDC)  
Ctrl pin connected to GND or low level  
(0-1.2VDC)  
Ctrl  
VRB121DLD-20WR3  
--  
5
--  
Input current when switched off  
mA  
Others  
--  
4
7
Hot Plug  
Unavailable  
Note: The voltage of Ctrl pin is relative to input pin GND.  
Output Specifications  
Item  
Operating Conditions  
Min.  
--  
Typ.  
Max.  
±3  
Unit  
%
Output Voltage Accuracy  
0%-100% load  
±1  
Positive output  
Negative output  
Positive output  
Negative output  
--  
±0.2  
±0.5  
±0.5  
±0.5  
±0.5  
±1  
Full load,the input voltage is  
from low voltage to high voltage  
Line Regulation  
--  
--  
±1  
Load Regulation  
5%-100% load  
--  
±1.5  
Dual output, main output 50% load,  
Supplement output from 10%-100% load  
Cross Regulation  
--  
--  
±5  
Transient Recovery Time  
--  
--  
300  
±5  
±3  
--  
500  
±8  
µs  
%
25% load step change,  
Nominal input voltage  
3.3V/5V/±5V output  
Transient Response Deviation  
Temperature Coefficient  
Others  
--  
±5  
%/  
mVp-p  
Full load  
--  
±0.03  
250  
100  
--  
VRB121DLD-20WR3  
Others  
--  
--  
20MHz bandwidth, 5%-100%  
load  
Ripple & Noise  
--  
50  
±10  
--  
Trim  
--  
Input voltage range(24V/48V input)  
%Vo  
%Io  
Over-voltage Protection  
110  
--  
160  
--  
VRB121DLD-20WR3  
Others  
130  
--  
Over-current Protection  
Input voltage range  
110  
190  
Short circuit Protection  
Note:  
Hiccup, Continuous, self-recovery  
At 0%~5% load, the Max. output voltage accuracy of ±5VDC/±9VDC output converter is ±5%;  
When testing from 0% to100%load working conditionsload regulation index of ±5%;  
0%-5% load ripple&Noise is no more than 5%Vo.Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application Notes  
for specific operation.  
2018.08.16-A/4  
Page 2 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
VRA_LD-20WR3 & VRB_LD-20WR3 Series  
General Specifications  
Item  
Operating Conditions  
Min.  
1500  
1000  
--  
Typ.  
--  
Max.  
Unit  
VDC  
MΩ  
Input-output, with the test time of 1 minute and the leak  
current lower than 1mA  
Input-output, insulation voltage 500VDC  
Insulation Voltage  
Insulation Resistance  
--  
--  
--  
--  
VRB2424LD-20W(H)R3  
(A2S/A4S)  
2050  
Isolation Capacitance  
Input-output, 100KHz/0.1V  
VRB121DLD-20WR3  
pF  
--  
--  
2000  
1050  
--  
--  
--  
Others  
Operating Temperature  
Storage Temperature  
Storage Humidity  
see Fig. 1  
-40  
-55  
5
+85  
+125  
95  
--  
Non-condensing  
--  
%RH  
Pin Welding Resistance  
Temperature  
Max. Casing Temperature  
Vibration  
Welding spot is 1.5mm away from the casing, 10 seconds  
Refer to temperature derating curve (VRB121DLD-20WR3)  
--  
--  
+300  
--  
--  
105  
10-55Hz, 10G, 30 Min. along X, Y and Z  
VRB121DLD-20WR3  
--  
--  
300  
270  
--  
--  
--  
--  
Switching Frequency  
PWM mode  
Others  
KHz  
MIL-HDBK-217F@25℃  
MTBF  
1000  
K hours  
Note: This series of products using reduced frequency technology, the switching frequency is test value of full load,When the load is reduced to below 50%,  
the switching frequency decreases with decreasing load.  
Physical Specifications  
Casing Material  
Aluminum alloy  
Horizontal package( without heat sink)  
Horizontal package( with heat sink)  
A2S wiring package ( without heat sink)  
A2S wiring package( with heat sink)  
A4S rail package( without heat sink)  
A4S rail package( with heat sink)  
50.80*25.40*11.80 mm  
51.40*26.20*16.50 mm  
76.00*31.50*21.20 mm  
76.00*31.50*25.30 mm  
76.00*31.50*25.80 mm  
76.00*31.50*29.90 mm  
26g/48g/68g(Typ.)  
Dimension  
without heat sink  
with heat sink  
Horizontal package/A2S wiring package/A4S rail package  
Horizontal package/A2S wiring package/A4S rail package  
Weight  
34g/56g/76g(Typ.)  
Cooling Method  
Free air convection  
EMC Specifications  
CISPR32/EN55032 CLASS A (without external component)/ CLASS B (see Fig.3-for  
recommended circuit)  
CE  
EMI  
RE  
CISPR32/EN55032 CLASS A (without external component)/ CLASS B (see Fig.3-for  
recommended circuit)  
(except VRB121DLD-20WR3)  
ESD  
RS  
IEC/EN61000-4-2 Contact ±4KV  
perf. Criteria B  
IEC/EN61000-4-3 10V/m  
perf. Criteria A  
perf. Criteria B  
perf. Criteria B  
perf. Criteria A  
IEC/EN61000-4-4 ±2KV (see Fig.3-for recommended circuit)  
IEC/EN61000-4-5 line to line ±2KV (see Fig.3-for recommended circuit)  
IEC/EN61000-4-6 3 Vr.m.s  
EFT  
EMS  
Surge  
CS  
Voltage dips, short interruptions  
and voltage variations immunity  
IEC/EN61000-4-29 0%, 70%  
perf. Criteria B  
2018.08.16-A/4  
Page 3 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
VRA_LD-20WR3 & VRB_LD-20WR3 Series  
Product Characteristic Curve  
others  
VRB121DLD-20WR3  
Fig. 1  
2018.08.16-A/4  
Page 4 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
VRA_LD-20WR3 & VRB_LD-20WR3 Series  
Design Reference  
1. Typical application  
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.  
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or  
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product.  
Dual  
Vin  
+Vo  
0V  
Cout  
Cout  
Cin  
Cin  
DC DC  
Single Vout  
(VDC)  
Cout  
(µF)  
470  
Cin  
(µF)  
Dual Vout  
(VDC)  
±5  
Cout  
(µF)  
220  
Cin  
(µF)  
GND  
-Vo  
3.3/5  
Single  
Vin  
9/12/15  
24/110  
220  
100  
100  
±9/±12/±15  
±24  
100  
100  
100  
+Vo  
0V  
Cout  
DC DC  
Fig. 2  
GND  
2. EMC solution-recommended circuit  
Single:  
Parameter description  
Model  
Vin:12V/24V  
Vin:48V  
FUSE  
C0  
Choose according to actual input current  
Dual:  
680µF/100V  
1µF/50V  
680µF/100V  
1µF/100V  
C1  
C2  
330µF/50V  
330µF/100V  
C3 / C4  
LDM1  
CY1/ CY2  
Refer to the Cout in Fig.2  
4.7µH  
1nF/2KV  
Fig. 3  
Notes: Part in the Fig. 3 is used for EMI test and part for EMC filtering;  
selected based on needs.  
3. Application of Trim and calculation of Trim resistance  
Vo’  
Vo’  
R1  
RT  
R1  
R3  
Vref  
R2  
Trim  
R3  
Vref  
Trim  
RT  
R2  
0V  
Trim down  
0V  
Trim up  
Applied circuits of Trim (Part in broken line is the interior of models)  
Calculation formula of Trim resistance:  
aR2  
R2-a  
Vref  
Vo’-Vref  
-R3  
-R3  
up:  
RT=  
RT=  
a=  
a=  
R1  
R2  
RT is Trim resistance  
a is a self-defined parameter, with  
no real meaning.  
aR1  
R1-a  
Vo’-Vref  
Vref  
down:  
2018.08.16-A/4  
Page 5 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
VRA_LD-20WR3 & VRB_LD-20WR3 Series  
Vout(V)  
R1(KΩ)  
4.801  
R2(KΩ)  
2.87  
R3(KΩ)  
12.4  
10  
Vref(V)  
1.24  
2.5  
3.3  
5
2.883  
2.87  
9
7.500  
2.87  
15  
2.5  
12  
15  
24  
11.000  
14.494  
24.872  
2.87  
15  
2.5  
2.87  
15  
2.5  
2.87  
17.8  
2.5  
4. It is not allowed to connect modules output in parallel to enlarge the power  
5. For more information please find DC-DC converter application notes on www.mornsun-power.com  
Horizontal Package (without heat sink) Dimensions and Recommended Layout  
THIRD ANGLE PROJECTION  
1.50 [0.059]  
6
5
4
3
Front View  
11.80 [0.465]  
1
2
1.00 [0.039]  
50.80 [2.000]  
20.32 [0.800]  
Note:Grid 2.54*2.54mm  
Pin-Out  
3
2
Bottom View4  
1
Single  
GND  
Vin  
Dual  
GND  
Vin  
Pin  
1
5
6
2
3
+Vo  
Trim  
0V  
+Vo  
0V  
4
Note:  
Unit :mm[inch]  
5
-Vo  
Ctrl  
6
Ctrl  
Pin diameter tolerances :±0.10[±0.004]  
General tolerances:±0.50[±0.020]  
2018.08.16-A/4  
Page 6 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
VRA_LD-20WR3 & VRB_LD-20WR3 Series  
Horizontal Package (with heat sink) Dimensions  
VRA_LD-20WR3A2S & VRB_LD-20WR3A2S(without heat sink) Dimensions  
2018.08.16-A/4  
Page 7 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
VRA_LD-20WR3 & VRB_LD-20WR3 Series  
VRA_LD-20WHR3A2S & VRB_LD-20WHR3A2S(with heat sink) Dimensions  
VRA_LD-20WR3A4S & VRB_LD-20WR3A4S(without heat sink) Dimensions  
2018.08.16-A/4  
Page 8 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  
DC/DC Converter  
VRA_LD-20WR3 & VRB_LD-20WR3 Series  
VRA_LD-20WHR3A4S & VRB_LD-20WHR3A4S(with heat sink) Dimensions  
Notes:  
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com.The  
Packing bag number of Horizontal package :58200035(without heat sink), 58200051(with heat sink, A2S/ A4S package number:  
58220022;  
2. The maximum capacitive load offered were tested at input voltage range and full load;  
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75%RH with nominal  
input voltage and rated output load;  
4. All index testing methods in this datasheet are based on Company’s corporate standards;  
5. We can provide product customization service, please contact our technicians directly for specific information;  
6. Products are related to laws and regulations: see "Features" and "EMC";  
7. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by  
qualified units.  
Mornsun Guangzhou Science & Technology Co., Ltd.  
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China  
Tel: 86-20-38601850  
Fax: 86-20-38601272  
E-mail: sales@mornsun.cn www.mornsun-power.com  
2018.08.16-A/4  
Page 9 of 9  
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation  

相关型号:

VRA2405LD-30WR2

DUAL OUTPUT DC-DC CONVERTER
MORNSUN

VRA2405XD-10WR2

DC-DC Regulated Power Supply Module
MORNSUN

VRA2405XD-10WR2A2S

DC-DC Regulated Power Supply Module
MORNSUN

VRA2405YMD-6WR2

Analog Circuit
MORNSUN

VRA2405YMD-6WR3

DC-DC Regulated Power Supply Module, 2 Output, 6W, Hybrid, PACKAGE-5
MORNSUN

VRA2405ZP-10WR3

10W,wide input, isolated & regulated dual/ single output, DIP package, DC-DC converter
MORNSUN

VRA2405ZP-6WR2

DC-DC Regulated Power Supply Module
MORNSUN

VRA2405ZP-6WR3

DC-DC Regulated Power Supply Module, 2 Output, 6W, Hybrid, DIP-23/8
MORNSUN

VRA2409LD-20WR3

DC-DC Regulated Power Supply Module, 2 Output, 19.998W, Hybrid, PACKAGE-6
MORNSUN

VRA2409LD-30WR2

DUAL OUTPUT DC-DC CONVERTER
MORNSUN

VRA2412D-10WR2

DC-DC Regulated Power Supply Module
MORNSUN

VRA2412D-10WR2A2S

DC-DC Regulated Power Supply Module
MORNSUN