WRA0505S-1WR2_15 [MORNSUN]
DC/DC Converter;型号: | WRA0505S-1WR2_15 |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | DC/DC Converter |
文件: | 总6页 (文件大小:1340K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC/DC Converter
WRA_S-1WR2 & WRB_S-1WR2 Series
1W, Wide input voltage, isolated & regulated output
DC/DC converter
FEATURES
Ultra compact SIP package
Wide range of input voltage (2:1)
Operating temperature range: -40℃ to +85℃
Isolation voltage: 1.5K VDC
Low ripple & noise
Short circuit protection (self-recovery)
Remote On/Off
Patent Protection RoHS
WRA_S-1WR2 & WRB_S-1WR2 series are isolated 1W DC-DC products with 2:1 input voltage and conventional voltage output. The product
has a relatively compact SIP-8 plastic package, and features high efficiency, operating temperature of -40 ℃~+85 ℃, remote control,
and continuous short-circuit protection. The smaller size and fine cost design make the converter an ideal solution in communication,
instruments, and industrial electronics applications.
Selection Guide
Input Voltage (VDC)
Output
Output Current
Efficiency (%,
Min./Typ.)
@ Full Load
Max. Capacitive
Ripple & Noise
(mVp-p)
Part No.
②
Load (µF)
Nominal
Output
Voltage(VDC)
①
Max.
(Range)
(mA)(Max./Min.)
±100/±5
±42/±2
±33/±2
303/15
200/10
83/4
WRA0505S-1WR2
WRA0512S-1WR2
WRA0515S-1WR2
WRB0503S-1WR2
WRB0505S-1WR2
WRB0512S-1WR2
WRB0515S-1WR2
WRB0524S-1WR2
WRA1205S-1WR2
WRA1212S-1WR2
WRA1215S-1WR2
WRB1203S-1WR2
WRB1205S-1WR2
WRB1209S-1WR2
WRB1212S-1WR2
WRB1215S-1WR2
WRB1224S-1WR2
WRA2405S-1WR2
WRA2409S-1WR2
WRA2412S-1WR2
WRA2415S-1WR2
WRB2403S-1WR2
WRB2405S-1WR2
WRB2412S-1WR2
WRB2415S-1WR2
WRB2424S-1WR2
WRA4805S-1WR2
WRA4812S-1WR2
WRA4815S-1WR2
WRB4803S-1WR2
WRB4805S-1WR2
WRB4812S-1WR2
WRB4815S-1WR2
±5
±12
±15
3.3
5
71/73
74/76
73/75
69/71
70/72
74/76
73/75
71/73
76/78
79/81
76/78
73/75
75/77
77/79
77/79
78/80
74/76
77/79
77/79
77/79
77/79
73/75
75/77
78/80
76/78
75/77
74/76
76/78
78/80
73/75
74/76
78/80
77/79
1000
470
330
1800
2200
1000
680
5
11
(4.5-9)
12
15
67/3
40/75
24
42/2
470
±5
±12
±15
3.3
5
±100/±5
±42/±2
±33/±2
303/15
200/10
111/6
1000
470
330
2700
2200
1800
1000
680
12
20
(9-18)
9
12
83/4
70/100
15
67/3
24
42/2
100/150
470
±5
±9
±12
±15
3.3
5
±100/±5
±56/±3
±42/±2
±33/±2
303/15
200/10
83/4
1000
680
470
40/75
330
24
40
2700
2200
1000
680
(18-36)
12
15
67/3
70/100
24
42/2
100/150
470
±5
±12
±15
3.3
5
±100/±5
±42/±2
±33/±2
303/15
200/10
83/4
1000
470
330
48
80
40/75
2700
2200
1000
680
(36-75)
12
15
67/3
Notes: ①Exceeding the maximum input voltage may cause permanent damage;
②For the dual output modules, the capacitive loads of positive and negative outputs are the same.
2015.08.26-A/4
Page 1 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
WRA_S-1WR2 & WRB_S-1WR2 Series
Input Specifications
Item
Operating Conditions
Min.
--
Typ.
Unit
mA
Max.
290/60
114/30
57/10
28/6
--
5VDC Input
12VDC Input
24VDC Input
48VDC Input
5VDC Input
12VDC Input
24VDC Input
48VDC Input
5VDC Input
12VDC Input
24VDC Input
48VDC Input
5VDC Input
12VDC Input
24VDC Input
48VDC Input
281/40
--
111/15
55/6
27/4
30
40
55
45
--
Input Current (full load/no-load)
--
--
--
mA
--
--
Reflected Ripple Current
Input Impulse Voltage (1sec. max.)
Starting Voltage
--
--
--
--
-0.7
-0.7
-0.7
-0.7
--
12
--
25
--
50
--
100
4.5
9
VDC
--
--
--
--
--
18
--
--
36
Input Filter
Hot Plug
Filter capacitor
Unavailable
Module turn-on
Module turn-off
The Ctrl end is suspended or of high resistance
Connect with high level (relative to the input
grounding) to make the 5-10mA current flows into
the Ctrl end.
Ctrl*
Note: * For use of Ctrl, please refer to the “design reference” in this manual.
Output Specifications
Item
Operating Conditions
Min.
--
Typ.
±2
Max.
±5
Unit
%
3.3V/5V output
5%-100% load,Input
Output Voltage Accuracy
voltage range
others
--
±1
±3
No-load Output Voltage Accuracy
Balance of Output Voltage
Line Regulation
Input voltage range
--
±1.5
±0.3
±0.2
±0.4
0.5
±5
Dual output, balanced load
Full load, the input voltage is from low to high
5%-100% load
--
±0.5
±0.5
±0.75
2
--
Load Regulation
--
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Short Circuit Protection
--
ms
%
25% load step change
Full load
--
±2.5
±0.02
±5
%/℃
--
±0.03
Continuous, self-recovery
Note: *Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application Notes for specific operation.
General Specifications
Item
Operating Conditions
Input-output, with the test time of 1 minute and
the leak current lower than 1mA
Min.
1500
Typ.
--
Max.
--
Unit
Isolation Voltage
VDC
Isolation Resistance
Input-output, isolation voltage 500VDC
Input-output, 100KHz/0.1V
1000
--
--
120
--
--
--
MΩ
Isolation Capacitance
Operating Temperature
Storage Temperature
pF
Derating if the temperature ≥85℃, (see Fig. 1)
-40
-55
85
125
--
℃
Welding spot is 1.5mm away from the casing,
10 seconds
Pin Welding Resistance Temperature
--
--
300
Storage Humidity
Switching Frequency (PFM Mode)
MTBF
Non-condensing
--
--
--
200
--
95
--
%RH
KHz
Full load, nominal input voltage
MIL-HDBK-217F@25
℃
1000
--
K hours
2015.08.26-A/4
Page 2 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
WRA_S-1WR2 & WRB_S-1WR2 Series
Physical Specifications
Casing Material
Dimension
Black flame-retardant and heat-resistant plastic (UL94-V0)
22.00*9.50*12.00 mm
4.90g(Typ.)
Weight
Cooling Method
Free convection
EMC Specifications
CE
CISPR22/EN55022 CLASS B (see Fig. 3-② for recommended circuit)
EMI
CISPR22/EN55022 CLASS B (see Fig. 3-
IEC/EN61000-4-2 Contact ±4KV
IEC/EN61000-4-3 10V/m
② for recommended circuit)
RE
ESD
RS
perf. Criteria B
perf. Criteria A
perf. Criteria B
perf. Criteria B
perf. Criteria A
EFT
IEC/EN61000-4-4 ±2KV (see Fig. 3-
① for recommended circuit)
EMS
IEC/EN61000-4-5 ±2KV (see Fig. 3-① for recommended circuit)
Surge
CS
IEC/EN61000-4-6 3 Vr.m.s
Voltage dips, short interruptions
and voltage variations immunity
IEC/EN61000-4-29 0%-70%
perf. Criteria B
Product Characteristic Curve
Temperature Derating Curve
120
100
80
60
Safe Operation Area
40
20
0
-40
0
40 60 85
Environment Temperature.(℃)
Fig 1
2015.08.26-A/4
Page 3 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
WRA_S-1WR2 & WRB_S-1WR2 Series
Design Reference
1. Recommended circuit
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 2) before delivery.
If a further decrease of the input and output ripple is required, properly increase the input & output of additional capacitors Cin1, Cin2, Cs
and Cout; or select capacitors of low equivalent impedance like series capacitor, etc. Cs is used to reduce ripple. No need to add Cs, if
ripple meets the demand .Appropriate filter capacitance shall be chosen, start-up problems may be caused if the capacitance is too
large. For each output circuit, under the condition of safe and reliable operation, the max. capacity of its filter capacitor should be lower
than the max. capacitive load.
Single
Lin
2
6
8
V in
+Vo
0V
C in1
D 1
Vin
Cin1
Cin2
Lin
5VDC&12VDC
100µF
24VDC&48VDC
C in2
10µF
1µF
C o ut
C S
1
G N D
Lc
7
47µF
C d
R
3
V c
4.7µH~12µH
Dual
Cs
10µF~22µF
100µF(Typ.)
Lin
Lout
2
1
6
Vin
+Vo
Cout
Lout
Cd
Cout
Cin1 Cin2
0V
2.2
μH~10μH
7
8
Cout
Lout
-Vo
GND
47nF/100V
Cd
D1 Ic
R
3
Vc
Fig. 2
2. EMC solution-recommended circuit
LDM1
FUSE
Vin
Vin
+Vo
D1
Cd
R
DC/DC
+
Ctrl
LOAD
Ctrl
C1
C2
C3
MOV
C0
GND
GND
-Vo
①
(0V)
②
③
CY1
Fig. 3
Parameter description:
Model
FUSE
MOV
C0
Vin:5VDC
Vin:12VDC
Vin:24VDC
Vin:48VDC
Slow blown fuses according to the actual input current selections of the clients
--
S14K25
1000µF/25V
4.7µF/50V
S14K35
S14K60
1000µF/16V
330µF/50V
330µF/100V
4.7µF/100V
C1
LDM1
C2
12µH
4.7µF/50V
4.7µF/100V
C3
Refer to the Cout in Fig.2
1nF/2KV
CY1
D1
RB160M-60/1A
VC -VD -1.0
R =
-300
R
IC
In accordance with the formula:
47nF/100V
Cd
Notes:
① Part ① in Fig. 3 is used for EMS test while part ② is used for EMI filtering; and parts ① and ② may be selected based on needs.
② VC is the voltage of the Ctrl end relative to the GND of the input grounding; VD is the positive-going conduction pressure drop of D1; IC is the current flows
into the Ctrl end and its value is generally 5-10mA, see Fig. 3-③ for the peripheral circuit of Ctrl end;
③ If there is no recommended parameters, no external component is required.
EMC solution-recommended circuit PCB layout
Fig. 4
Note: the min. distance of the bonding pads between input grounding and output grounding shall be ≥ 2mm.
2015.08.26-A/4
Page 4 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
WRA_S-1WR2 & WRB_S-1WR2 Series
3. Ctrl end
The modules are of normal output when the Ctrl end is suspended or of high resistance; the modules turn off when connecting with high
level (relative to the input grounding); notice that the current flows into the pin shall be 5 - 10mA, the modules will be permanently damaged
if the current exceeds its max. value (20mA in general).
The value of R can be derived as follows:
VC -VD -1.0
R =
-300
IC
For Detailed parameter, please refer to EMC solution-recommended circuit in this manual.
4. Input current
When the electricity is provided by the unstable power supply, please make sure that the range of the output voltage fluctuation and the
ripple voltage of the power supply do not exceed the indicators of the modules. Input current of power supply should afford the flash startup
current of this kind of DC/DC module(see Fig. 5).
Generally: Vin= 5V series Iave =450mA
Vin=12V series lave =220mA
Vin=24V series lave =110mA
Vin=48V series lave =55mA
Iave
Input Voltage
scope
Input Voltage (V)
Fig. 5
5. Output load requirements
When using, the minimum load of the module output should not be less than 5% of the nominal load.In order to meet the performance
parameters of this datasheet, please connect a 5% dummy load in parallel at the output end, the dummy load is generally a resistor, please
note that the resistor needs to be used in derating.
6. For more information please find DC-DC converter application notes on www.mornsun-power.com
Dimensions and Recommended Layout
2015.08.26-A/4
Page 5 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
WRA_S-1WR2 & WRB_S-1WR2 Series
Notes:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing
bag number: 58210004;
2. Recommend to use module with more than 5% load, if not, the ripple of the product may exceeds the specification, but does not
affect the reliability of the product;
3. The recommended unbalance degree of the dual output module load is ≤±5%; if the degree exceeds ±5%, than the product
performance cannot be guaranteed to comply with all parameters in the datasheet. Please contact our technicians directly for
specific information;
4. The maximum capacitive load offered were tested at nominal input voltage and full load;
5. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25℃, humidity<75% with nominal
input voltage and rated output load;
6. All index testing methods in this datasheet are based on Company’s corporate standards;
7. The performance parameters of the product models listed in this manual are as above, but some parameters of non-standard model
products may exceed the requirements mentioned above. Please contact our technicians directly for specific information;
8. We can provide product customization service;
9. Specifications are subject to change without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: info@mornsun.cn
2015.08.26-A/4
Page 6 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
相关型号:
©2020 ICPDF网 联系我们和版权申明