WRA_YMD-3W & WRB_YMD-3W Series
3W, WIDE INPUT, ISOLATED & REGULATED
DUAL/SINGLE OUTPUT DC-DC CONVERTER
multi-country patent protection RoHS
FEATURES
● Wide (2:1) Input Range
● Short Circuit Protection(automatic recovery)
● 1500VDC Isolation
● Operating Temperature: -40°C ~ +85°C
● No heat sink required
PRODUCT PROGRAM
Input
Voltage (VDC)
Nominal Range
Output
Current (mA)
Part
Number
Efficiency
(%, Typ)
Voltage
(VDC)
Max*
11
Max
±300
±125
±100
600
Min
±30
±12
±10
60
WRA0505YMD-3W
WRA0512YMD-3W
WRA0515YMD-3W
WRB0505YMD-3W
WRB0512YMD-3W
WRB0515YMD-3W
WRA1205YMD-3W
WRA1212YMD-3W
WRA1215YMD-3W
WRB1205YMD-3W
WRB1209YMD-3W
WRB1212YMD-3W
WRB1215YMD-3W
WRB1224YMD-3W
WRA2405YMD-3W
WRA2412YMD-3W
WRA2415YMD-3W
WRB2405YMD-3W
WRB2409YMD-3W
WRB2412YMD-3W
WRB2415YMD-3W
WRB2424YMD-3W
WRA4805YMD-3W
WRA4812YMD-3W
WRA4815YMD-3W
WRB4805YMD-3W
WRB4809YMD-3W
WRB4812YMD-3W
WRB4815YMD-3W
WRB4824YMD-3W
±5
±12
±15
5
68
72
71
68
72
71
76
80
80
77
78
80
81
80
77
80
80
77
79
81
81
80
77
80
81
77
79
81
81
80
● No external component required
● Internal SMD required
● Five sided metal shielding
● MTBF>1000Khours
5
4.5-9
12
15
±5
±12
±15
5
250
25
● RoHS Compliance
200
20
±300
±125
±100
600
±30
±12
±10
60
APPLICATIONS
The WRA_YMD-3W & WRB_YMD-3W Series are
specially designed for applications where a wide
range input voltage power supplies are isolated from
the input power supply in a distributed power supply
system on a circuit board.
12
9-18
22
40
80
9
333
33
12
15
24
±5
±12
±15
5
250
25
200
20
These products apply to:
125
12
1) Where the voltage of the input power supply is
wide range (Voltage range≤2:1);
±300
±125
±100
600
±30
±12
±10
60
2) Where isolation is necessary between input and
output(Isolation voltage≤1500VDC);
3) Where the regulation of the output voltage and
the output ripple noise are demanded.
24
18-36
9
333
33
12
15
24
±5
±12
±15
5
250
25
MODEL SELECTION
WRA0505YMD-3W
200
20
125
12
Rated Power
Package Style
Output Voltage
Input Voltage
±300
±125
±100
600
±30
±12
±10
60
Product Series
48
36-72
9
333
33
12
15
24
250
25
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Huangzhou Industrial
District, Guangzhou, China
200
20
125
12
Tel: 86-20-38601850
Fax:86-20-38601272
Http://www.mornsun-power.com
* Input voltage can’t exceed this value, or will cause the permanent damage.
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
A/2-2009 Page 1 of 3
WRA_YMD-3W & WRB_YMD-3W
OUTPUT SPECIFICATIONS
TYPICAL TEMPERATURE CURVE
Item
Test Conditions
Min
0.3
Typ.
Max.
3
Units
W
Output power
Positive voltage accuracy
Refer to products program
Refer to recommended circuit
±1
±3
±3
Negative voltage accuracy Refer to recommended circuit
±5
%
Load regulation
Form 10% to 100% load
Input voltage from low to high
Refer to recommended circuit
20MHz Bandwidth
±0.5
±0.2
±1*
±0.5
±0.03
150
Line regulation
Temperature drift (Vout)
Ripple & Noise**
Switching frequency
%/°C
mVp-p
KHz
75
100% load, input voltage range
300
*Dual output models unbalanced load: ±5%.
**Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
Operating Temp.(
C)
COMMON SPECIFICATIONS
RECOMMENDED CIRCUIT
Item
Test Conditions
Min.
Typ.
15
Max.
95
Units
%
Storage humidity
Operating temperature
Storage temperature
Temp. rise at full load
Lead temperature
Cooling
+Vout
0V
Vin
-40
-55
85
Cin
DC DC
125
°C
GND
-Vout
1.5mm from case for 10 seconds
300
Single Output
Vin
+Vout
0V
Free Air Convection
Cin
DC DC
Short circuit protection
Case material
Continuous, Automatic recovery
Aluminium Alloy
GND
No-load power consumption
Isolation voltage
Isolation resistance
Isolation Capacitance
MTBF
0.2
W
VDC
MΩ
(Figure 1)
Tested for1 minute and 1mA max
Test at 500VDC
1500
1000
Input/output
100
15
pF
Ip
1000
K hours
g
Weight
Input Voltage
Range
APPLICATION NOTE
Requirement on output load
Input Voltage (V)
In order to ensure the product operate efficiently and reliably, in addition to a max load
(namely full load), a minimum load is specified for this kind of DC/DC converter. Make sure the
specified range of input voltage is not exceeded, the minimum output load no less than 10%
load. If the actual load is less than the specified minimum load, the output ripple may increase
sharply while its efficiency and reliability will reduce greatly. If the actual output power is very
small, please add an appropriate resistor as extra loading, or contact our company for other
lower output power products.
Output External Capacitor Table(Table 1)
Single Vout
(VDC)
Cout
(uF)
Dual Vout
(VDC)
Cout
(uF)
3.3
5
2200
1000
680
±5
±9
±12
±15
-
680
470
330
220
-
Recommended Circuit
9
All the WRA_YMD-3W & WRB_YMD-3W Series have been tested according to the following
recommended testing circuit before leaving factory. This series should be tested under load
(see Figure 1).
12
15
24
470
330
220
-
-
If you want to further decrease the input/output ripple, you can increase capacitance properly
or choose capacitors with low ESR. However, the capacitance of the output filter capacitor must
be proper. If the capacitance is too big, a startup problem might arise. For every channel of
output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter
capacitor sees (Table 1). General:
Cin:
5V&12V
100μF
24V&48V
10μF-47μF
Cout: 10μF/100mA
Input current
While using unstable power source, please ensure the output voltage and ripple voltage do
not exceed indexes of the converter. The preceding power source must be able to provide for
converter sufficient starting current Ip (Figure 2). General: Ip ≤1.4*Iin-max
No parallel connection or plug and play
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
WRA_YMD-3W & WRB_YMD-3W A/2-2009 Page 2 of 3
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
DUAL/SINGLE OUTPUT
25.40 [1.000]
20.32 [0.800]
∅1.20 [∅0.047]
3
4
5
4
5
3
(Bottom View)
2
1
2
1
5.08 [0.200]
2.54 [0.100]
(Side View)
TUBE OUTLINE DIMENSIONS
0.50 [0.020]
30.20 [1.189]
0.80[0.031]
Note:
Unit:mm[inch]
Pin diameter tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
FOOTPRINT DETAILS
Pin
1
Single
GND
Vin
Dual
GND
Vin
12.80 [0.504]
2
+Vo
3
+Vo
0V
Note:
Unit :mm[inch]
General tolerances: ±0.50mm[±0.020inch]
4
No Pin
0V
5
-Vo
L=530mm[20.866inch] Tube Quantity: 19pcs
L=220mm[8.661inch] Tube Quantity: 7pcs
NC:No connection
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. Only typical models listed, other models may be different, please contact our technical person for more details.
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
A/2-2009 Page 3 of 3
WRA_YMD-3W & WRB_YMD-3W
相关型号:
©2020 ICPDF网 联系我们和版权申明