SN54/74LS390  
SN54/74LS393  
DUAL DECADE COUNTER;  
DUAL 4-STAGE  
BINARY COUNTER  
DUAL DECADE COUNTER;  
DUAL 4-STAGE  
TheSN54/74LS390andSN54/74LS393eachcontainapairofhigh-speed  
4-stage ripple counters. Each half of the LS390 is partitioned into a  
divide-by-two section and a divide-by five section, with a separate clock input  
for each section. The two sections can be connected to count in the 8.4.2.1  
BCD code or theycancountinabiquinarysequencetoprovideasquarewave  
(50% duty cycle) at the final output.  
BINARY COUNTER  
LOW POWER SCHOTTKY  
Each half of the LS393 operates as a Modulo-16 binary divider, with the last  
three stages triggered in a ripple fashion. In both the LS390 and the LS393,  
the flip-flops are triggered by a HIGH-to-LOW transition of their CP inputs.  
Each half of each circuit type has a Master Reset input which responds to a  
HIGH signal by forcing all four outputs to the LOW state.  
J SUFFIX  
CERAMIC  
CASE 620-09  
Dual Versions of LS290 and LS293  
16  
1
LS390 has Separate Clocks Allowing ÷2, ÷2.5, ÷5  
Individual Asynchronous Clear for Each Counter  
Typical Max Count Frequency of 50 MHz  
N SUFFIX  
PLASTIC  
Input Clamp Diodes Minimize High Speed Termination Effects  
CASE 648-08  
16  
1
CONNECTION DIAGRAM DIP (TOP VIEW)  
D SUFFIX  
SOIC  
CASE 751B-03  
SN54/74LS390  
16  
1
J SUFFIX  
CERAMIC  
CASE 632-08  
14  
1
N SUFFIX  
PLASTIC  
NOTE:  
CASE 646-06  
The Flatpak version  
has the same pinouts  
(Connection Diagram) as  
14  
SN54/74LS393  
1
the Dual In-Line Package.  
D SUFFIX  
SOIC  
CASE 751A-02  
14  
1
ORDERING INFORMATION  
SN54LSXXXJ  
Ceramic  
SN74LSXXXN Plastic  
SN74LSXXXD SOIC  
FAST AND LS TTL DATA  
5-544  
SN54/74LS390 SN54/74LS393  
PIN NAMES  
LOADING (Note a)  
HIGH  
LOW  
CP  
CP  
CP  
Clock (Active LOW going edge)  
Input to +16 (LS393)  
0.5 U.L.  
0.5 U.L.  
1.0 U.L.  
1.0 U.L.  
Clock (Active LOW going edge)  
Input to ÷2 (LS390)  
0
1
Clock (Active LOW going edge)  
Input to ÷5 (LS390)  
0.5 U.L.  
0.5 U.L.  
10 U.L.  
1.5 U.L.  
0.25 U.L.  
5 (2.5) U.L.  
MR  
Q Q  
0
Master Reset (Active HIGH) Input  
Flip-Flop outputs (Note b)  
3
NOTES:  
a) 1 TTL Unit Load (U.L.) = 40 µA HIGH/1.6 mA LOW.  
b) The Output LOW drive factor is 2.5 U.L. for Military (54) and 5 U.L. for Commercial (74)  
b) Temperature Ranges.  
FUNCTIONAL DESCRIPTION  
Each half of the SN54/74LS393 operates in the Modulo 16  
binary sequence, as indicated in the ÷16 Truth Table. The first  
flip-flop is triggered by HIGH-to-LOW transitions of the CP  
input signal. Each of the other flip-flops is triggered by a  
HIGH-to-LOW transition of the Q output of the preceding  
flip-flop. Thus state changes of the Q outputs do not occur  
simultaneously. This means that logic signals derived from  
combinations of these outputs will be subject to decoding  
spikes and, therefore, should not be used as clocks for other  
counters, registers or flip-flops. A HIGH signal on MR forces  
all outputs to the LOW state and prevents counting.  
section operates in 4.2.1 binary sequence, as shown in the ÷5  
Truth Table, with the third stage output exhibiting a 20% duty  
cycle when the input frequency is constant. To obtain a ÷10  
function having a 50% duty cycle output, connect the input  
signal to CP and connect the Q output to the CP input; the  
1
3
0
Q output provides the desired 50% duty cycle output. If the  
0
input frequency is connected to CP and the Q output is  
connected to CP , a decade divider operating in the 8.4.2.1  
1
0
0
BCD codeisobtained, asshownintheBCDTruthTable.Since  
the flip-flops change state asynchronously, logic signals  
derived from combinations of LS390 outputs are also subject  
to decoding spikes. A HIGH signal on MR forces all outputs  
LOW and prevents counting.  
Each half of the LS390 contains a ÷5 section that is  
independent except for the common MR function. The ÷5  
SN54/74LS390 LOGIC DIAGRAM (one half shown)  
SN54/74LS393 LOGIC DIAGRAM (one half shown)  
FAST AND LS TTL DATA  
5-545  
SN54/74LS390 SN54/74LS393  
SN54/74LS390 BCD  
TRUTH TABLE  
SN54/74LS390 ÷5  
TRUTH TABLE  
SN54/74LS393  
TRUTH TABLE  
(Input on CP ; Q CP )  
(Input on CP )  
0
0
1
1
OUTPUTS  
OUTPUTS  
OUTPUTS  
COUNT  
COUNT  
COUNT  
Q
Q
Q
Q
Q
Q
Q
Q
Q
Q
Q
0
3
2
1
0
3
2
1
3
2
1
0
1
2
L
L
L
L
L
L
L
L
H
L
H
L
0
1
2
3
4
L
L
L
L
H
L
L
H
L
H
L
0
1
2
3
L
L
L
L
H
L
L
H
H
L
L
L
L
L
L
L
L
H
H
H
3
4
5
L
L
L
L
H
H
H
L
L
H
L
H
4
5
6
7
L
L
L
L
H
H
H
H
L
L
H
H
L
H
L
6
7
8
9
L
L
H
H
H
H
L
H
H
L
L
H
L
H
SN54/74LS390 ÷10 (50% @ Q )  
0
8
9
10  
11  
H
H
H
H
L
L
L
L
L
L
H
H
L
H
L
TRUTH TABLE  
(Input on CP , Q to CP )  
L
L
H
1
3
0
H
OUTPUTS  
COUNT  
12  
13  
14  
15  
H
H
H
H
H
H
H
H
L
L
H
H
L
H
L
Q
Q
Q
Q
0
3
2
1
0
1
2
L
L
L
L
L
H
L
H
L
L
L
L
H
3
4
5
L
H
L
H
L
L
H
L
L
L
L
H
H = HIGH Voltage Level  
L = LOW Voltage Level  
6
7
8
9
L
L
L
L
H
H
L
H
L
H
L
H
H
H
H
H
GUARANTEED OPERATING RANGES  
Symbol  
Parameter  
Min  
Typ  
Max  
Unit  
V
CC  
Supply Voltage  
54  
74  
4.5  
4.75  
5.0  
5.0  
5.5  
5.25  
V
T
A
Operating Ambient Temperature Range  
54  
74  
55  
0
25  
25  
125  
70  
°C  
I
I
Output Current — High  
Output Current — Low  
54, 74  
0.4  
mA  
mA  
OH  
54  
74  
4.0  
8.0  
OL  
FAST AND LS TTL DATA  
5-546  
SN54/74LS390 SN54/74LS393  
DC CHARACTERISTICS OVER OPERATING TEMPERATURE RANGE (unless otherwise specified)  
Limits  
Min  
Typ  
Max  
Symbol  
Parameter  
Input HIGH Voltage  
Unit  
Test Conditions  
Guaranteed Input HIGH Voltage for  
All Inputs  
V
2.0  
V
IH  
54  
74  
0.7  
0.8  
Guaranteed Input LOW Voltage for  
All Inputs  
V
V
V
Input LOW Voltage  
V
IL  
Input Clamp Diode Voltage  
Output HIGH Voltage  
0.65  
3.5  
1.5  
V
V
V
V
V
= MIN, I = 18 mA  
IN  
IK  
CC  
54  
74  
2.5  
2.7  
= MIN, I  
OH  
= MAX, V = V  
IN  
CC  
IH  
OH  
or V per Truth Table  
IL  
3.5  
V
V
= V  
CC  
MIN,  
= V or V  
IL IH  
54, 74  
74  
0.25  
0.35  
0.4  
0.5  
V
V
I
I
= 4.0 mA  
= 8.0 mA  
CC  
IN  
OL  
V
Output LOW Voltage  
Input HIGH Current  
OL  
per Truth Table  
OL  
20  
0.1  
µA  
mA  
mA  
mA  
mA  
mA  
mA  
V
V
= MAX, V = 2.7 V  
IN  
CC  
I
IH  
= MAX, V = 7.0 V  
IN  
CC  
MR  
CP, CP  
0.4  
1.6  
2.4  
100  
26  
I
IL  
Input LOW Current  
V
= MAX, V = 0.4 V  
IN  
0
CC  
CP  
1
I
I
Short Circuit Current (Note 1)  
Power Supply Current  
20  
V
V
= MAX  
= MAX  
OS  
CC  
CC  
CC  
Note 1: Not more than one output should be shorted at a time, nor for more than 1 second.  
AC CHARACTERISTICS (T = 25°C, V  
CC  
= 5.0 V)  
A
Limits  
Typ  
Min  
Max  
Symbol  
Parameter  
Maximum Clock Frequency  
Unit  
Test Conditions  
f
f
25  
35  
MHz  
MAX  
CP to Q  
0
0
Maximum Clock Frequency  
CP to Q  
20  
MHz  
ns  
MAX  
1
1
t
t
Propagation Delay,  
CP to Q  
12  
13  
20  
20  
PLH  
PHL  
LS393  
0
t
t
12  
13  
20  
20  
PLH  
PHL  
CP to Q  
LS390  
LS393  
LS390  
LS390  
LS390  
ns  
0
0
t
t
40  
40  
60  
60  
PLH  
PHL  
CP to Q  
ns  
3
C
= 15 pF  
L
t
t
37  
39  
60  
60  
PLH  
PHL  
CP to Q  
ns  
0
2
1
2
3
t
t
13  
14  
21  
21  
PLH  
PHL  
CP to Q  
ns  
1
t
t
24  
26  
39  
39  
PLH  
PHL  
CP to Q  
ns  
1
t
t
13  
14  
21  
21  
PLH  
PHL  
CP to Q  
LS390  
ns  
ns  
1
t
MR to Any Output  
LS390/393  
24  
39  
PHL  
FAST AND LS TTL DATA  
5-547  
SN54/74LS390 SN54/74LS393  
AC SETUP REQUIREMENTS (T = 25°C, V  
CC  
= 5.0 V)  
A
Limits  
Typ  
Min  
20  
20  
40  
20  
25  
Max  
Symbol  
Parameter  
Clock Pulse Width  
Unit  
ns  
Test Conditions  
t
t
t
t
t
LS393  
LS390  
LS390  
W
W
W
W
rec  
CP Pulse Width  
0
ns  
CP Pulse Width  
1
ns  
V
CC  
= 5.0 V  
MR Pulse Width  
Recovery Time  
LS390/393  
LS390/393  
ns  
ns  
AC WAVEFORMS  
Figure 1  
Figure 2  
*The number of Clock Pulses required between t  
and t measurements can be determined from the appropriate Truth Table.  
PLH  
PHL  
FAST AND LS TTL DATA  
5-548  
Case 751B-03 D Suffix  
16-Pin Plastic  
SO-16  
-A-  
16  
1
9
8
P
C
-B-  
R X 45°  
G
-T-  
J
M
F
D
°
°
°
°
K
Case 648-08 N Suffix  
16-Pin Plastic  
-A-  
16  
1
9
B
S
8
F
L
C
K
-T-  
M
H
J
G
D
°
°
°
°
Case 620-09 J Suffix  
16-Pin Ceramic Dual In-Line  
-A-  
16  
9
-B-  
1
8
L
C
-T-  
K
M
N
E
J
F
G
D
°
°
°
°
FAST AND LS TTL DATA  
5-549  
Motorolareserves the right to make changes without further notice to any products herein. Motorola makes no warranty, representationorguaranteeregarding  
the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any product or circuit,  
andspecifically disclaims any and all liability, includingwithoutlimitationconsequentialorincidentaldamages. “Typical” parameters can and do vary in different  
applications. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. Motorola does  
not convey any license under its patent rights nor the rights of others. Motorola products are not designed, intended, or authorized for use as components in  
systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of  
the Motorola product could create a situation where personal injury or death may occur. Should Buyer purchase or use Motorola products for any such  
unintendedor unauthorized application, Buyer shall indemnify and hold Motorola and its officers, employees, subsidiaries, affiliates, and distributors harmless  
against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death  
associated with such unintended or unauthorized use, even if such claim alleges that Motorola was negligent regarding the design or manufacture of the part.  
Motorola and  
are registered trademarks of Motorola, Inc. Motorola, Inc. is an Equal Opportunity/Affirmative Action Employer.  
Literature Distribution Centers:  
USA: Motorola Literature Distribution; P.O. Box 20912; Phoenix, Arizona 85036.  
EUROPE: Motorola Ltd.; European Literature Centre; 88 Tanners Drive, Blakelands, Milton Keynes, MK14 5BP, England.  
JAPAN: Nippon Motorola Ltd.; 4-32-1, Nishi-Gotanda, Shinagawa-ku, Tokyo 141, Japan.  
ASIA PACIFIC: Motorola Semiconductors H.K. Ltd.; Silicon Harbour Center, No. 2 Dai King Street, Tai Po Industrial Estate, Tai Po, N.T., Hong Kong.  

相关型号:

SN74LS390D3

Decade Counter,
ROCHESTER

SN74LS390DE4

DUAL 4-BIT DECADE AND BINARY COUNTERS
TI

SN74LS390DG4

DUAL 4-BIT DECADE AND BINARY COUNTERS
TI

SN74LS390DR

DUAL 4-BIT DECADE AND BINARY COUNTERS
TI

SN74LS390DR2

LS SERIES, ASYN NEGATIVE EDGE TRIGGERED 3-BIT UP DECADE COUNTER, PDSO16, SOIC-16
MOTOROLA

SN74LS390DRE4

DUAL 4-BIT DECADE AND BINARY COUNTERS
TI

SN74LS390DRG4

DUAL 4-BIT DECADE AND BINARY COUNTERS
TI

SN74LS390J

LS SERIES, ASYN NEGATIVE EDGE TRIGGERED 3-BIT UP DECADE COUNTER, CDIP16, CERAMIC, DIP-16
TI

SN74LS390J-00

LS SERIES, ASYN NEGATIVE EDGE TRIGGERED 3-BIT UP DECADE COUNTER, CDIP16
TI

SN74LS390JD

Decade Counter, LS Series, Asynchronous, Negative Edge Triggered, 3-Bit, Up Direction, TTL, CDIP16, CERAMIC, DIP-16
MOTOROLA

SN74LS390JDS

LS SERIES, ASYN NEGATIVE EDGE TRIGGERED 3-BIT UP DECADE COUNTER, CDIP16, CERAMIC, DIP-16
MOTOROLA

SN74LS390JP4

Decade Counter,
ROCHESTER