ICF-1280I-S-ST-T [MOXA]

Industrial PROFIBUS-to-fiber converters with redundant fiber ring;
ICF-1280I-S-ST-T
型号: ICF-1280I-S-ST-T
厂家: Moxa    Moxa
描述:

Industrial PROFIBUS-to-fiber converters with redundant fiber ring

文件: 总4页 (文件大小:2331K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ICF-1280I Series  
Industrial PROFIBUS-to-fiber converters with redundant fiber ring  
Features and Benefits  
Redundant fiber ring with zero recovery time  
Examines network-wide fiber communication from a single converter  
Auto baudrate detection and data speed of up to 12 Mbps  
PROFIBUS fail-safe prevents corrupted datagrams in functioning segments  
Alarm by relay output  
2 kV galvanic isolation protection  
Dual power inputs for redundancy  
Extends PROFIBUS transmission distance up to 45 km  
Wide-temperature model available for -40 to 75°C environments  
Supports Fiber Signal Intensity Diagnosis  
Certifications  
Introduction  
The ICF-1280I industrial PROFIBUS-to-fiber converters are used to convert PROFIBUS signals from copper to optical fiber. The converters are  
used to extend serial transmission up to 4 km (multi-mode fiber) or up to 45 km (single-mode fiber). The ICF-1280I Series provides 2 kV isolation  
protection for the PROFIBUS system and dual power inputs to ensure that your PROFIBUS device will perform uninterrupted.  
Remote Fiber Diagnosis  
Optical fiber cables are often deployed for long-distance communication and a fiber-optic inspection pen is used by engineers to ensure proper  
communication quality of the fiber cable. The ICF-1280I Series eliminates the need for a fiber-optic inspection pen by providing a Remote Fiber  
Diagnosis function that uses DIP switch adjustments.  
There are two major functions provided by Remote Fiber Diagnosis: (1) determining which side (Tx or Rx) is causing the problem on the converter;  
(2) examining the fiber connections for the overall topology from any individual converter. Fiber cable abnormalities can be automatically detected  
and identified by the LED indicator even if it is not adjacent to the converter. Remote Fiber Diagnosis facilitates fiber cable deployment and  
management, and also significantly shortens troubleshooting time by examining fiber connections for the overall topology from any individual  
converter.  
Redundant Ring  
The ICF-1280I Series of converters can connect PROFIBUS devices in  
a redundant fiber ring topology. Use the DIP switch to configure all  
the ICF- 1280I converters to redundant ring mode. When a PROFIBUS  
master transmits a signal from one converter to the PROFIBUS slave  
devices, this signal will travel to all the converters around the ring  
until it returns to the original converter and terminate. The redundant  
ring structure ensures no packet loss with zero recovery time.  
1
www.moxa.com  
PROFIBUS Fail-safe  
Electrical noise may be generated when a PROFIBUS device  
malfunctions or the serial interface fails, resulting in bus failure.  
Traditional media converters transmit noise signals through the fiber  
wire to the other converter. This not only disrupts data  
communication between the two buses, but will also bring  
communication across the entire system to a halt. When this occurs,  
the engineers will not be able to easily locate the failed device  
because the entire PROFIBUS network is down. To avoid this  
situation, the ICF-1280I Series has a mechanism to detect and  
recognize noise signals. If the bus fails on one side, the noise signal  
will not propagate through the ICF-1280I converter and affect  
additional bus segments. In addition, the ICF-1280I converter will also  
trigger an alarm to provide the location of the failure to the field  
engineer.  
Auto/Manual Baudrate Settings  
The ICF-1280I converters convert signals back and forth between PROFIBUS and fiber at baudrates between 9.6 kbps to 12 Mbps. Engineers do  
not need to know the baudrate of the connected PROFIBUS device; the ICF-1280I converters can automatically detect the baudrate of the  
PROFIBUS device and apply this baudrate directly. This is an extremely convenient feature. If necessary, baudrates can be set to a fixed value via  
DIP switches to shorten the baudrate detection period when the system initializes.  
Fiber Link Monitor  
The ICF-1280I converters support a fiber link monitoring function to detect communication errors on both sides of the fiber connection and  
determine which side (Tx or Rx) is causing the problem. When a communication error occurs, a red LED status indicator will turn on and the relay  
alarm will activate. If a fiber abnormality occurs at a remote fiber segment, the Fault LED will flash to indicate the abnormality was in the remote  
segment. Engineers can use the fiber test function for troubleshooting.  
Fiber Signal Intensity Diagnosis  
In some circumstances, you may need to measure the receive level of the fiber-optic port with a voltmeter, which can be connected while the  
device is operating (doing so will not affect data transmission). The measurement can be taken with a voltmeter and read on a PLC that uses  
floating high impedance analog inputs, which allow you to do the following:  
Record the incoming optical power for later measurement (e.g., to indicate aging or damage).  
Carry out a good/bad test (limit value).  
Specifications  
Serial Interface  
Optical Fiber  
ICF-1280I-M-SC Series: 100BaseFX ports (multi-mode SC connector)  
ICF-1280I-M-ST Series: 100BaseFX ports (multi-mode ST connector)  
ICF-1280I-S-SC Series: 100BaseFX ports (single-mode SC connector)  
ICF-1280I-S-ST Series: 100BaseFX ports (single-mode ST connector)  
100BaseFX ports (multi-mode SC connector)  
100BaseFX ports (multi-mode SC connector)  
100BaseFX ports (single-mode SC connector)  
100BaseFX ports (single-mode SC connector)  
Multi-Mode  
Single-Mode  
Wavelength  
Tx Output  
820 nm  
1310 nm  
-7 dBm  
-29 dBm  
21 dBm  
45 km  
-14 dBm  
-28 dBm  
14 dBm  
4 km  
Rx Sensitivity  
Link Budget  
Typical Distance  
PROFIBUS Interface  
Baudrate  
9600 bps to 12 Mbps  
DB9 female  
PROFIBUS DP  
2 kV (built-in)  
1
Connector  
Industrial Protocols  
Isolation  
No. of Ports  
2
www.moxa.com  
Power Parameters  
Input Current  
370 mA @ 12 to 48 VDC  
12 to 48 VDC  
Input Voltage  
No. of Power Inputs  
Overload Current Protection  
Power Connector  
2
Supported  
Terminal block (for DC models)  
370 mA @ 12 to 48 VDC  
Power Consumption  
Physical Characteristics  
Housing  
Metal  
IP Rating  
Dimensions  
Weight  
IP30  
39 x 115 x 70 mm (1.54 x 4.53 x 2.76 in)  
225 g (0.49 lb)  
Installation  
DIN-rail mounting  
Environmental Limits  
Operating Temperature  
Standard Models: 0 to 60°C (32 to 140°F)  
Wide Temp. Models: -40 to 75°C (-40 to 167°F)  
0 to 60°C (32 to 140°F)  
-40 to 75°C (-40 to 167°F)  
0 to 60°C (32 to 140°F)  
-40 to 75°C (-40 to 167°F)  
Storage Temperature (package included)  
Ambient Relative Humidity  
-40 to 75°C (-40 to 167°F)  
5 to 95% (non-condensing)  
Standards and Certifications  
EMC  
EN 55032/24  
EMI  
CISPR 32, FCC Part 15B Class A  
EMS  
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV  
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m  
IEC 61000-4-4 EFT: Power: 0.5 kV  
IEC 61000-4-5 Surge: Power: 0.5 kV  
IEC 61000-4-6 CS: 3 V  
IEC 61000-4-8 PFMF  
Environmental Testing  
IEC 60068-2-1  
IEC 60068-2-2  
IEC 60068-2-3  
Hazardous Locations  
Safety  
ATEX, Class I Division 2, IECEx  
EN 60950-1, IEC 60950-1  
IEC 60068-2-6  
Vibration  
MTBF  
Time  
1,870,854 hrs  
Standards  
Telcordia (Bellcore), GB  
3
www.moxa.com  
Warranty  
Warranty Period  
5 years  
Details  
See www.moxa.com/warranty  
Package Contents  
Device  
1 x ICF-1280I Series converter  
Documentation  
1 x quick installation guide  
1 x warranty card  
Dimensions  
Ordering Information  
Model Name  
Operating Temp.  
0 to 60°C  
Fiber Module Type  
Multi-mode ST  
Single-mode ST  
Multi-mode ST  
Single-mode ST  
ICF-1280I-M-ST  
ICF-1280I-S-ST  
ICF-1280I-M-ST-T  
ICF-1280I-S-ST-T  
0 to 60°C  
-40 to 75°C  
-40 to 75°C  
© Moxa Inc. All rights reserved. Updated Apr 14, 2020.  
This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of  
Moxa Inc. Product specifications subject to change without notice. Visit our website for the most up-to-date product information.  
4
www.moxa.com  

相关型号:

ICF-308-F-I

IC Socket, DIP8, 8 Contact(s), 2.54mm Term Pitch, 0.24inch Row Spacing,
SAMTEC

ICF-308-F-I-TR

IC Socket, DIP8, 8 Contact(s), 2.54mm Term Pitch, 0.24inch Row Spacing,
SAMTEC

ICF-308-F-O

IC Socket, DIP8, 8 Contact(s), 2.54mm Term Pitch, 0.36inch Row Spacing,
SAMTEC

ICF-308-F-O-TR

IC Socket, DIP8, 8 Contact(s), 2.54mm Term Pitch, 0.36inch Row Spacing,
SAMTEC

ICF-308-FM-I-TR

IC Socket, DIP8, 8 Contact(s),
SAMTEC

ICF-308-FM-O

IC Socket, DIP8, 8 Contact(s),
SAMTEC

ICF-308-FM-O-TR

IC Socket, DIP8, 8 Contact(s),
SAMTEC

ICF-308-S-O

IC Socket, DIP8, 8 Contact(s), 2.54mm Term Pitch, 0.34inch Row Spacing, Surface Mount, ROHS COMPLIANT
SAMTEC

ICF-308-S-O-TR

IC Socket, DIP8, 8 Contact(s), 2.54mm Term Pitch, Surface Mount, ROHS COMPLIANT
SAMTEC

ICF-308-SM-O-TR

IC Socket, DIP8, 8 Contact(s),
SAMTEC

ICF-308-STL-I

IC Socket, DIP8, 8 Contact(s),
SAMTEC

ICF-308-STL-O

IC Socket, DIP8, 8 Contact(s),
SAMTEC