ioLogik E1200 Series
Ethernet remote I/O with 2-port Ethernet switch
Features and Benefits
• User-definable Modbus TCP Slave addressing
1
• Supports EtherNet/IP Adapter mode
• Supports RESTful API for IIoT applications
• 2-port Ethernet switch for daisy-chain topologies
• Saves time and wiring costs with peer-to-peer communications
• Active communication with MX-AOPC UA Server
• Supports SNMP v1/v2c
• Easy mass deployment and configuration with ioSearch utility
• Friendly configuration via web browser
• Simplifies I/O management with MXIO library for Windows or Linux
2
• Class I Division 2, ATEX Zone 2 certification
• Wide operating temperature models available for -40 to 75°C (-40 to 167°F)
environments
Certifications
Introduction
The ioLogik E1200 Series supports the most often-used protocols for retrieving I/O data, making it capable of handling a wide variety of
applications. Most IT engineers use SNMP or RESTful API protocols, but OT engineers are more familiar with OT-based protocols, such as Modbus
and EtherNet/IP. Moxa's Smart I/O makes it possible for both IT and OT engineers to conveniently retrieve data from the same I/O device. The
ioLogik E1200 Series speaks six different protocols, including Modbus TCP, EtherNet/IP, and Moxa AOPC for OT engineers, as well as SNMP,
RESTful API, and Moxa MXIO library for IT engineers. The ioLogik E1200 retrieves I/O data and converts the data to any of these protocols at the
same time, allowing you to get your applications connected easily and effortlessly.
Daisy-Chained Ethernet I/O Connection
This industrial Ethernet remote I/O comes with two switched Ethernet ports to allow for the free flow of information downstream to another local
Ethernet device, or upstream to a control server via expandable daisy-chained Ethernet I/O arrays. Applications such as factory automation,
security and surveillance systems, and tunneled connections can make use of daisy-chained Ethernet for building multidrop I/O networks over
standard Ethernet cables. Many industrial automation users are familiar with multidrop as the configuration most typically used in fieldbus
solutions. The daisy-chain capabilities supported by ioLogik Ethernet remote I/O units not only increase the expandability and installation
possibilities for your remote I/O applications, but also lower overall costs by reducing the need for separate Ethernet switches. Daisy-chaining
devices in this way will also reduce overall labor and cabling expenses.
1.
2.
Requires online registration (available free of charge)
Class I Division 2 and ATEX currently do not apply to the E1213/E1213-T models.
1
www.moxa.com
Save Time and Wiring Costs with Peer-to-Peer Communications
In remote automation applications, the control room and sensors are
often far removed, making wiring over long distances a constant
challenge. With peer-to-peer networking, users may now map a pair
of ioLogik Series modules so that input values will be directly
transferred to output channels, greatly simplifying the wiring process
and reducing wiring costs.
User-Definable Modbus TCP Addressing for Painless Upgrading of Existing Systems
For Modbus devices that are controlled and detected by fixed
addresses, users need to spend a vast amount of time researching
and verifying initial configurations. Users need to locate each device’s
networking details, such as I/O channels or vendor-defined
addresses, to enable the initial or start address of a SCADA system or
PLC. Devices that support user-definable Modbus TCP addressing
offer greater flexibility and easier setup. Instead of worrying about
individual devices, users simply configure the function and address
map to fit their needs.
Push Technology for Events
When used with MX-AOPC UA Server, devices can use active push
communications when communicating changes in state and/or
events to a SCADA system. Unlike a polling system, when using a
push architecture for communications with a SCADA system,
messages will only be delivered when changes in state or configured
events occur, resulting in higher accuracy and lower amounts of data
that need to be transferred.
Specifications
Input/Output Interface
Analog Input Channels
ioLogik E1240 models: 8
ioLogik E1242 models: 4
Analog Output Channels
ioLogik E1241 models: 4
ioLogik E1212 models: 8
Configurable DIO Channels (by jumper)
2
www.moxa.com
ioLogik E1213/E1242 models: 4
Digital Input Channels
Digital Output Channels
ioLogik E1210 models: 16
ioLogik E1212/E1213 models: 8
ioLogik E1214 models: 6
ioLogik E1242 models: 4
ioLogik E1211 models: 16
ioLogik E1213 models: 4
Isolation
3k VDC or 2k Vrms
Relay Channels
RTD Channels
Thermocouple Channels
Buttons
ioLogik E1214 models: 6
ioLogik E1260 models: 6
ioLogik E1262 models: 8
Reset button
Digital Inputs
Connector
Screw-fastened Euroblock terminal
250 Hz
Counter Frequency
Digital Filtering Time Interval
Dry Contact
Software configurable
On: short to GND
Off: open
I/O Mode
DI or event counter
Points per COM
ioLogik E1210/E1212 models: 8 channels
ioLogik E1213 models: 12 channels
ioLogik E1214 models: 6 channels
ioLogik E1242 models: 4 channels
Sensor Type
Dry contact
Wet contact (NPN or PNP)
Wet Contact (DI to COM)
On: 10 to 30 VDC
Off: 0 to 3 VDC
Digital Outputs
Connector
Screw-fastened Euroblock terminal
Current Rating
ioLogik E1211/E1212/E1242 models: 200 mA per channel
ioLogik E1213 models: 500 mA per channel
I/O Mode
I/O Type
DO or pulse output
ioLogik E1211/E1212/E1242 models: Sink
ioLogik E1213 models: Source
Over-Current Protection
ioLogik E1211/E1212/E1242 models: 2.6 A per channel @ 25°C
ioLogik E1213 models: 1.5 A per channel @ 25°C
Over-Temperature Shutdown
Over-Voltage Protection
Pulse Output Frequency
175°C (typical), 150°C (min.)
35 VDC
500 Hz (max.)
3
www.moxa.com
Relays
Breakdown Voltage
500 VAC
Connector
Screw-fastened Euroblock terminal
Resistive load: 5 A @ 30 VDC, 250 VAC, 110 VAC
100 milli-ohms (max.)
Contact Current Rating
Contact Resistance
Electrical Endurance
Initial Insulation Resistance
Mechanical Endurance
Pulse Output Frequency
Type
100,000 operations @ 5 A resistive load
1,000 mega-ohms (min.) @ 500 VDC
5,000,000 operations
0.3 Hz at rated load (max.)
Form A (N.O.) power relay
Note
Ambient humidity must be non-condensing and remain between 5 and 95%. The relays
may malfunction when operating in high condensation environments below 0°C.
Analog Inputs
Accuracy
ioLogik E1240/E1242:
0.1% FSR @ 25°C
0.3% FSR @ -10 to 60°C
ioLogik E1240-T/E1242-T:
0.1% FSR @ 25°C
0.3% FSR @ -10 to 60°C
0.5% FSR @ -40 to 75°C
Built-in Resistor for Current Input
Connector
120 ohms
Screw-fastened Euroblock terminal
Voltage/Current
I/O Mode
I/O Type
Differential
Input Impedance
Input Range
10 mega-ohms (min.)
0 to 10 VDC
0 to 20 mA
4 to 20 mA
4 to 20 mA (with burn-out detection)
Resolution
16 bits
Sampling Rate
ioLogik E1240: 12 samples/sec per module (shared between up to 8 channels)3
ioLogik E1242: 12 samples/sec per module (shared between up to 4 channels)3
Analog Outputs
Accuracy
ioLogik E1241:
0.1% FSR @ 25°C
0.3% FSR @ -10 to 60°C
ioLogik E1241-T:
0.1% FSR @ 25°C
0.3% FSR @ -40 to 75°C
Connector
Screw-fastened Euroblock terminal
Voltage Output Short-Circuit Protection
Internal Resistor
10 mA
400 ohms
3.
If N channels are enabled, the sampling rate for each enabled channel = 12/N samples/sec.
4
www.moxa.com
Note: 24 V of external power required when loading exceeds 1000 ohms
Output Range
Resolution
0 to 10 VDC
4 to 20 mA
12-bit
RTDs
Accuracy
ioLogik E1260:
0.1% FSR @ 25°C
0.3% FSR @ -10 to 60°C
ioLogik E1260-T:
0.1% FSR @ 25°C
0.3% FSR @ -40 to 75°C
Connector
Screw-fastened Euroblock terminal
2- or 3-wire
Input Connection
Input Impedance
Sensor Type
625 kilo-ohms (min.)
PT1000 (-200 to 350°C)
PT50, PT100, PT200, PT500 (-200 to 850°C)
Resistance Type
Resolution
310, 620, 1250, and 2200 ohms
0.1°C or 0.1 ohms
Sampling Rate
ioLogik E1260: 12 samples/sec per module (shared between up to 6 channels)4
Thermocouples
Millivolt Accuracy
ioLogik E1262:
0.1% FSR @ 25°C
0.3% FSR @ -10 to 60°C
ioLogik E1262-T:
0.1% FSR @ 25°C
0.3% FSR @ -40 to 75°C
Connector
Screw-fastened Euroblock terminal
TC Accuracy
Types J, T, E, S, B: 5°C
Types K, R, N: 8°C
CJC Accuracy
0.5°C @ 25°C
1.5°C @ -40 to 75°C
Input Impedance
Millivolt Type
10 mega-ohms (min.)
19.532 mV
39.062 mV
78.126 mV
Fault and over-voltage protection: -35 to +35 VDC (power off); -25 to +30 VDC (power
on)
Resolution
16 bits
Sampling Rate
Sensor Type
ioLogik E1262: 12 samples/sec per module (shared between up to 8 channels)4
J, K, T, E, R, S, B, N
4.
If N channels are enabled, the sampling rate for each enabled channel = 12/N samples/sec.
5
www.moxa.com
Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector)
2, 1 MAC address (Ethernet bypass)
1.5 kV (built-in)
Magnetic Isolation Protection
Ethernet Software Features
Configuration Options
Web Console (HTTP), Windows Utility (ioSearch)
Industrial Protocols
Management
EtherNet/IP Adapter, Modbus TCP Server (Slave), Moxa AOPC (Active Tag), MXIO
Library
BOOTP, RESTful API, DHCP Client, HTTP, IPv4, TCP/IP, UDP, SNMPv1 Trap, SNMPv1/
v2c
MIB
Device Settings MIB
Access control list
Security
LED Interface
LED Indicators
Power, Ready, Port 1, Port 2
Modbus TCP
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
Mode
Server (Slave)
10
Max. No. of Client Connections
EtherNet/IP
Mode
Adapter
Max. No. of Scanner Connections
9 (for read-only), 1 (for read/write)
Power Parameters
Power Connector
Screw-fastened Euroblock terminal
No. of Power Inputs
Input Voltage
1
12 to 36 VDC
Power Consumption
ioLogik E1210 Series: 110 mA @ 24 VDC
ioLogik E1211 Series: 200 mA @ 24 VDC
ioLogik E1212 Series: 155 mA @ 24 VDC
ioLogik E1213 Series: 130 mA @ 24 VDC
ioLogik E1214 Series: 188 mA @ 24 VDC
ioLogik E1240 Series: 121 mA @ 24 VDC
ioLogik E1241 Series: 194 mA @ 24 VDC
ioLogik E1242 Series: 139 mA @ 24 VDC
ioLogik E1260 Series: 110 mA @ 24 VDC
ioLogik E1262 Series: 118 mA @ 24 VDC
Physical Characteristics
Housing
Plastic
Dimensions
Weight
27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in)
200 g (0.44 lb)
Installation
Wiring
DIN-rail mounting, Wall mounting
I/O cable, 16 to 26 AWG
Power cable, 12 to 24 AWG
6
www.moxa.com
Environmental Limits
Operating Temperature
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included)
Ambient Relative Humidity
Altitude
-40 to 85°C (-40 to 185°F)
5 to 95% (non-condensing)
4000 m5
Standards and Certifications
EMC
EN 55032/24, EN 61000-6-2/-6-4
CISPR 32, FCC Part 15B Class A
EMI
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
Hazardous Locations
Safety
ATEX, Class I Division 26
UL 508
Shock
IEC 60068-2-27
IEC 60068-2-32
IEC 60068-2-6
Freefall
Vibration
Declaration
Green Product
RoHS, CRoHS, WEEE
MTBF
Time
ioLogik E1210 Series: 671,345 hrs
ioLogik E1211 Series: 923,027 hrs
ioLogik E1212 Series: 561,930 hrs
ioLogik E1213 Series: 715,256 hrs
ioLogik E1214 Series: 808,744 hrs
ioLogik E1240 Series: 474,053 hrs
ioLogik E1241 Series: 888,656 hrs
ioLogik E1242 Series: 502,210 hrs
ioLogik E1260 Series: 660,260 hrs
ioLogik E1262 Series: 631,418 hrs
Standards
Telcordia SR332
Warranty
Warranty Period
ioLogik E1214: 2 years7
ioLogik E1210/E1211/E1212/E1213/E1240/E1241/E1242/E1260/E1262: 5 years
Details
See www.moxa.com/warranty
5.
6.
7.
Please contact Moxa if you require products guaranteed to function properly at higher altitudes.
ATEX and Class I Division 2 currently do not apply to the ioLogik E1213/E1213-T models.
Because of the limited lifetime of power relays, products that use this component are covered by a 2-year warranty.
7
www.moxa.com
Package Contents
Device
1 x ioLogik E1200 Series remote I/O
Installation Kit
1 x terminal block, 8-pin, 3.81 mm
1 x terminal block, 12-pin, 3.81 mm
1 x terminal block, 3-pin, 5.00 mm
Documentation
1 x quick installation guide
1 x warranty card
Dimensions
Ordering Information
Model Name
Input/Output Interface
Digital Output Type
Operating Temp.
-10 to 60°C
-40 to 75°C
-10 to 60°C
-40 to 75°C
-10 to 60°C
-40 to 75°C
-10 to 60°C
-40 to 75°C
-10 to 60°C
-40 to 75°C
-10 to 60°C
-40 to 75°C
-10 to 60°C
-40 to 75°C
-10 to 60°C
-40 to 75°C
ioLogik E1210
ioLogik E1210-T
ioLogik E1211
ioLogik E1211-T
ioLogik E1212
ioLogik E1212-T
ioLogik E1213
ioLogik E1213-T
ioLogik E1214
ioLogik E1214-T
ioLogik E1240
ioLogik E1240-T
ioLogik E1241
ioLogik E1241-T
ioLogik E1242
ioLogik E1242-T
16 x DI
16 x DI
–
–
16 x DO
Sink
Sink
Sink
Sink
Source
Source
–
16 x DO
8 x DI, 8 x DIO
8 x DI, 8 x DIO
8 x DI, 4 x DO, 4 x DIO
8 x DI, 4 x DO, 4 x DIO
6 x DI, 6 x Relay
6 x DI, 6 x Relay
8 x AI
–
–
8 x AI
–
4 x AO
–
4 x AO
–
4 DI, 4 x DIO, 4 x AI
4 DI, 4 x DIO, 4 x AI
Sink
Sink
8
www.moxa.com
Model Name
Input/Output Interface
6 x RTD
Digital Output Type
Operating Temp.
-10 to 60°C
-40 to 75°C
-10 to 60°C
-40 to 75°C
ioLogik E1260
ioLogik E1260-T
ioLogik E1262
ioLogik E1262-T
–
–
–
–
6 x RTD
8 x TC
8 x TC
Accessories (sold separately)
Software
MX-AOPC UA Server
OPC UA Server software for converting fieldbus to the OPC UA standard
© Moxa Inc. All rights reserved. Updated Apr 30, 2020.
This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of
Moxa Inc. Product specifications subject to change without notice. Visit our website for the most up-to-date product information.
9
www.moxa.com
相关型号:
©2020 ICPDF网 联系我们和版权申明