B1200RU Series  
Ulltraa--WWide Innppuutt 1122WW  
Single & Dual Ouuttppuutt  
DCC//DDCC CCoonnveerrtteerrss  
Electrical Specications  
Specications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specications subject to change without notice.  
Input  
Parameter  
Conditions  
24 VDC Input  
48 VDC Input 14.0  
π (Pi) Filter (Complies with EN55022 Class “A”)  
Min.  
Typ.  
8.5  
16.0  
Max.  
9.0  
18.0  
Units  
Key Features:  
12W Output Power  
8.0  
Input Start Voltage  
VDC  
UL Approved (File E245422)  
4:1 Input Voltage Range  
1,500 VDC Isolation  
Input Filter  
Reverse Polarity Input Current  
Short Circuit Input Power  
Output  
1.0  
3,500  
A
mW  
Compact 1 x 2 Inch Case  
Single & Dual Outputs  
Optional Remote ON/OFF  
Parameter  
Conditions  
Min.  
Typ.  
±0.5  
±0.5  
±0.1  
±0.2  
50  
Max.  
±1.0  
±1.0  
±0.5  
±0.5  
75  
Units  
%
%
%
%
mV P - P  
mV P - P  
mV rms  
%
μSec  
%
Output Voltage Accuracy  
Output Voltage Balance  
Industry Standard Pin-Out Line Regulation  
Dual Output , Balanced Loads  
Vin = Min to Max  
Load Regulation  
Ripple & Noise (20 MHz) (Note 1)  
Iout = 10% to 100%  
Ripple & Noise (20 MHz)  
Ripple & Noise (20 MHz)  
Output Power Protection  
Transient Recovery Time (Note 2)  
Transient Response Deviation  
Temperature Coefcient  
Output Short Circuit  
General  
Over Line, Load & Temp.  
25% Load Step Change  
100  
15  
120  
150  
±1.5  
±0.01 ±0.02  
250  
±2.5  
%/°C  
Continuous  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
VDC  
VDC  
MΩ  
pF  
kHz  
Isolation Voltage  
60 Seconds 1,500  
Isolation Test Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Environmental  
Parameter  
Flash Tested For 1 Sec 1,650  
500 VDC 1,000  
100 kHz, 1V  
500  
400  
600  
450  
350  
Conditions  
Min.  
-40  
-40  
-40  
Typ.  
Max.  
+71  
+90  
Units  
°C  
°C  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Humidity  
RFI  
Ambient  
Case  
+25  
+125  
°C  
Free Air Convection (See Curves on Page 2)  
RH, Non-condensing 95  
Six-Side Shielded Metal Case  
%
MicroPower Direct  
232 Tosca Drive  
Stoughton, MA 02072  
USA  
Physical  
Case Size  
Case Material  
Weight  
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)  
Metal with Non-Conductive Base (UL94-V0)  
1.13 Oz (32g)  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Reliability Specications  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
MTBF  
MIL HDBK 217F, 25°C, Gnd Benign  
700  
kHours  
Safety Standards  
Safety Approvals  
Absolute Maximum Ratings  
Parameter  
UL 1950, EN 60950, IEC 60950  
UL, cUL; File No. E245422  
Conditions  
Min.  
Typ.  
Max.  
42.0  
Units  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
VDC  
84.0  
Lead Temperature  
Internal Power Dissipation  
1.5 mm From Case For 10 Sec  
All Models  
260.0  
5,000  
°C  
mW  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
Model Selection Guide  
Input  
Output  
Over  
Voltage  
Protection (%, Typ)  
(VDC)  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Number  
Efciency  
Voltage (VDC)  
Current (mA)  
Voltage Current  
(VDC) (mA, Max) (mA, Min)  
Current  
Full-  
Load  
423  
No-  
Load  
10  
Nominal  
Range  
B1201RU  
B1202RU  
B1203RU  
B1204RU  
B1205RU  
B1206RU  
B1207RU  
B1211RU  
B1212RU  
B1213RU  
B1214RU  
B1215RU  
B1216RU  
B1217RU  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
48  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
3.3  
5.0  
2,400  
2,000  
1,000  
800  
240.0  
200.0  
100.0  
80.0  
3.9  
6.8  
78  
82  
84  
84  
82  
84  
84  
78  
82  
84  
84  
82  
84  
84  
1,500  
1,500  
1,500  
1,500  
1,500  
1,500  
1,500  
750  
508  
595  
595  
508  
595  
595  
212  
254  
298  
298  
254  
298  
298  
10  
10  
10  
10  
10  
10  
5
12.0  
15.0  
±5.0  
±12.0  
±15.0  
3.3  
15.0  
18.0  
±6.8  
±15.0  
±18.0  
3.9  
±1000  
±500  
±400  
2,400  
2,000  
1,000  
800  
±100.0  
±50.0  
±40.0  
240.0  
200.0  
100.0  
80.0  
5
5.0  
6.8  
750  
5
12.0  
15.0  
±5.0  
±12.0  
±15.0  
15.0  
18.0  
±6.8  
±15.0  
±18.0  
750  
5
750  
5
±1000  
±500  
±400  
±100.0  
±50.0  
±40.0  
750  
5
750  
5
750  
Notes:  
Derating Curve  
1. When measuring output ripple, it is recommended that an external  
0.47 μF ceramic capacitor be placed from the +Vout pin to the -Vout  
pin for single output units and from each output to common for dual  
output units. For noise sensitive applications, the use of 3.9 μF  
capacitors will reduce the output ripple.  
2. Transient recovery is measured to within a 1% error band for a  
load step change of 75% to 100%.  
3. Operation at no-load will not damage these units. However, they may  
not meet all specications.  
5. Dual output units may be connected to provide a 10 VDC, 24 VDC  
or 30 VDC output. To do this, connect the load across the positive  
(+Vout) and negative (-Vout) outputs and oat the output common.  
6. The converter should be connected to a low ac-impedance source.  
An input source with a highly inductive impedance may affect the  
stability of the converter. In applications where the converter output  
loading is high and input power is supplied over long lines, it may be  
necessary to use a capacitor on the input to insure start-up.  
In this case, it is recommended that a low Equivalent Series Resis-  
tance (ESR <1.0Ω at 100 kHz) capacitor be mounted close to the  
converter. A 10.0 μF is recommended for 24V input models; a 4.7μF  
for 48V units.  
7. It is recommended that a fuse be used on the input of a power supply  
for protection. See the table above for the correct rating.  
Mechanical Dimensions  
Remote ON/OFF (Optional, see below)  
Parameter  
Min  
Max  
5.5 or Open  
0.8  
Units  
VDC  
VDC  
mA  
Capacitive  
Load  
Single Output  
(μF Max)  
Supply On  
2.5  
Supply Off  
-0.7  
Standby Input Current  
Control Input Current (On)  
Control Input Current (Off)  
Control Common  
10  
50.0  
μA  
-100.0  
mA  
470  
Referenced to Neg. Input (pin 2)  
Remote ON/OFF Notes:  
Dual Output  
(μF Max)  
1. Maximum sink current at the on/off pin (pin 6) during a logic  
low is 100 μA.  
±150  
2. Maximum allowable leakage current of a switch connected to the  
on/off terminal (Pin 6) at logic high (2.5V to 100V) is 50 μA.  
Pin Connections  
Pin  
1
Single  
+Vin  
Dual  
+Vin  
2
-Vin  
-Vin  
3
+Vout  
+Vout  
4
5
No Pin  
-Vout  
Common  
-Vout  
Mechanical Notes:  
• All dimensions are typical in inches (mm)  
Tolerance x.xx = ±0.01 (±0.25)  
• Leads are gold plated for improved  
solderability.  
6
Remote On/Off  
Remote On/Off  
For Remote On/Off Option, add sufx “R” to model number (i.e. B1205RU-R)  
MicroPower Direct  
www.micropowerdirect.com  
232 Tosca Drive Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

B1205D-1WR2

1W, Fixed input voltage, isolated & unregulated single output
MORNSUN

B1205D-2W

DUAL/SINGLE OUTPUT DC-DC CONVERTER
MORNSUN

B1205GD1

DC-DC Regulated Power Supply Module, 2 Output, 1W, Hybrid, DIP-14/6
SENSITRON

B1205GD1U

DC-DC Unregulated Power Supply Module, 2 Output, 1W, Hybrid, DIP-14/6
SENSITRON

B1205GD1U-G

DC-DC Unregulated Power Supply Module, 2 Output, 1W, Hybrid, DIP-14/6
SENSITRON

B1205GD2U-G

DC-DC Unregulated Power Supply Module, 2 Output, 2W, Hybrid, DIP-14/6
SENSITRON

B1205GM1U

DC-DC Unregulated Power Supply Module, 2 Output, 1W, Hybrid,
SENSITRON

B1205GM1U-G

DC-DC Unregulated Power Supply Module, 2 Output, 1W, Hybrid,
SENSITRON

B1205GS1

DC-DC Regulated Power Supply Module, 2 Output, 1W, Hybrid, SIP-7/5
SENSITRON

B1205GS2U

DC-DC Unregulated Power Supply Module, 2 Output, 2W, Hybrid, SIP-7/5
SENSITRON

B1205HD1

DC-DC Regulated Power Supply Module, 1 Output, 1W, Hybrid, DIP-14/5
SENSITRON

B1205HD1U

DC-DC Unregulated Power Supply Module, 1 Output, 1W, Hybrid, DIP-14/5
SENSITRON