C2020RW [MPD]
Analog Circuit;型号: | C2020RW |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Analog Circuit |
文件: | 总2页 (文件大小:208K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
C2000RWSeries
Wide 2:1Input 20W
Single, Dual & Triple Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
12 VDC Input
Min.
9.0
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
75.0
Units
Key Features:
Input Voltage Range
24 VDC Input 18.0
48 VDC Input 36.0
(Pi) Filter
VDC
• 20W Output Power
• 2:1 Input Voltage Range
• 1,600 VDC Isolation
• 12, 24, & 48V Input
• Single, Dual, Triple Output
• Remote ON/OFF
Input Filter
Output
Parameter
Output Voltage Accuracy
Line Regulation, Single, Dual Output
Conditions
Min.
Typ.
2.0
0.5
1.0
5.0
0.5
3.0
3.0
5.0
Max.
Units
%
%
For Vin Min to Max
Vout 1
Vout 2 & Vout 3
Iout = 10% to 100%
Line Regulation, Triple Output
%
• >550 kHour MTBF
Load Regulation, Single Output
Load Regulation, Dual Output
%
%
• Industry Standard Pin-Out
Iout = 10% to 100%
Iout = 10% to 100%, Vout 1
Iout = 10% to 100%, Vout 2 & Vout 3
Load Regulation, Triple Output
%
Ripple, See Note 1
Noise, See Note 1
Output Power Protection, See Note 2
Over Voltage Protection, See Note 3
Temperature Coefficient
Output Short Circuit
General
0.2% Vout + 20 mV P - P Max.
0.5% Vout + 50 mV P - P Max.
120
112
0.02
%
%
%/°C
165
Continuous (Autorecovery)
Parameter
Conditions
Min.
60 Seconds 1,600
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
M⍀
pF
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off, See Note 4
Parameter
1,000
200
kHz
Conditions
Min.
5.0
Typ.
Max.
15.0
+1.0
-1
Units
VDC
VDC
mA
Supply On
Supply Off
-1.0
Input Current (On)
Input Current (Off)
Control Common
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
1
mA
Referenced to Negative Input (pin 2)
Conditions
Min.
Typ.
Max.
+70
+100
+105
Units
°C
°C
Ambient
Case
-25
-55
°C
See Derating Curve
RH, Non-condensing
Humidity
95
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
2.0 x 2.0 x 0.45 Inches (50.8 x 50.8 x 11.4 mm)
Nickel Coated Copper with Non-Conductive Base
2.47 Oz (70g)
Conditions
Min.
550
Typ.
Typ.
Max.
Units
kHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
MIL HDBK 217F, 25°C, Gnd Benign
Absolute Maximum Ratings
Parameter
Conditions
Min.
Max.
25.0
50.0
100.0
260
Units
VDC
°C
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (0.1 Sec)
Lead Temperature
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Max.
Fuse
Rating
Input
Output 1
Output 2
Output 3
Max.
Model
Number
Output Efficiency
Voltage (VDC)
Current (mA)
Capacitive
Load (µF)
Voltage Current Voltage Current Voltage Current
Power
(A, Max)
(W)
(Typ %)
Slow-Blow
(mA)
(VDC)
(A, Max)
(VDC)
(A, Max)
(VDC)
Nom. Range Full-Load No-Load
C2001RW 12
C2002RW 12
C2003RW 12
C2004RW 12
C2005RW 12
C2006RW 12
C2007RW 12
C2008RW 12
C2009RW 12
C2010RW 12
C2011RW 24 18 - 36
C2012RW 24 18 - 36
C2013RW 24 18 - 36
C2014RW 24 18 - 36
C2015RW 24 18 - 36
C2016RW 24 18 - 36
C2017RW 24 18 - 36
C2018RW 24 18 - 36
C2019RW 24 18 - 36
C2020RW 24 18 - 36
C2021RW 48 36 - 75
C2022RW 48 36 - 75
C2023RW 48 36 - 75
C2024RW 48 36 - 75
C2025RW 48 36 - 75
C2026RW 48 36 - 75
C2027RW 48 36 - 75
C2028RW 48 36 - 75
C2029RW 48 36 - 75
C2030RW 48 36 - 75
9 - 18
9 - 18
9 - 18
9 - 18
9 - 18
9 - 18
9 - 18
9 - 18
9 - 18
9 - 18
1,447
2,137
2,058
2,032
2,008
2,164
2,058
2,032
2,110
2,164
705
1,029
969
980
945
1,016
992
120
120
120
120
120
120
120
120
120
120
85
85
85
85
85
85
85
85
85
85
50
50
50
50
50
50
50
3.3
5.0
4.00
4.00
1.67
1.33
0.83
+2.00
+0.83 -12.00
+0.66 -15.00
2.50
2.50
4.00
4.00
1.67
1.33
0.83
+2.00
13.2
20.0
20.0
20.0
20.0
20.0
20.0
20.0
76
78
81
82
83
77
81
82
79
77
78
81
86
85
88
82
84
85
83
81
76
82
84
85
87
83
85
84
83
84
28,000
10,000
2,000
755
330
3,000
680
330
6,000/ 150
4,000/ 150
28,000
10,000
2,000
4,000
4,500
4,500
4,500
4,500
4,500
4,500
4,500
4,500
4,500
2,000
2,500
2,500
2,500
2,500
2,500
2,500
2,500
2,500
2,500
1,000
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
12.0
15.0
24.0
+5.0
+12.0
+15.0
5.0
5.0
3.3
5.0
12.0
15.0
24.0
+5.0
+12.0
+15.0
5.0
5.0
3.3
5.0
-5.0
-2.00
-0.83
-0.66
+0.30
+0.25
+12.0
+15.0
-12.0
-15.0
-0.30 20.0
-0.25 20.0
13.2
20.0
20.0
20.0
20.0
20.0
20.0
20.0
755
330
3,000
680
-5.0
-2.00
-0.83
-0.66
+0.30
+0.25
+0.83 -12.00
+0.66 -15.00
980
330
1,004
1,029
362
508
496
490
479
502
490
2.50
2.50
4.00
4.00
1.67
1.33
0.83
+2.00
+0.83 -12.00
+0.66 -15.00
2.50
2.50
+12.0
+15.0
-12.0
-15.0
-0.30 20.0
-0.25 20.0
13.2
6,000/ 150
4,000/ 150
28,000
10,000
2,000
20.0
20.0
20.0
20.0
20.0
20.0
20.0
12.0
15.0
24.0
+5.0
+12.0
+15.0
5.0
755
330
3,000
680
-5.0
-2.00
-0.83
-0.66
+0.30
+0.25
496
502
496
50
50
50
330
6,000/ 150
4,000/ 150
+12.0
+15.0
-12.0
-15.0
-0.30 20.0
-0.25 20.0
5.0
Notes:
Pin Connections
Derating Curve
0. When measuring output ripple, it is recommended that an external
0.± µF ceramic in parallel with a 0± µF capacitor be placed from
the +Vout pin to the -Vout pin.
2. The unit will recover automatically when the fault condition is
removed.
3. Over voltage protection is provided by a zener diode clamp.
4. If the on/off pin (Pin 4) is left open, the unit operates.
5. No load operation will not damage these units, but they may not
meet all spec’s.
6. Itisrecommendedthatafusebeusedontheinputofapowersupply
for protection. See the table above for the correct rating.
Pin Single
Dual
Triple
1
2
4
5
6
7
8
+Vin
-Vin
On/Off
NC
+Vout Common Vout 1
-Vout
Trim
+Vin
-Vin
On/Off
Vout 1
+Vin
-Vin
On/Off
Vout 2
Vout 2 Common
Trim Vout 3
NC = No Connection
Mechanical Dimensions
External Trim
A simple external circuit may be used to adjust
the converter output.To adjust the output DOWN,
connect a 5%, 3W resistor between the plus
output pin and the Vout trim pin. To adjust the
output UP, connect a 5%, 3W resistor between the
minus output pin and the Vout trim pin.
For UP/Down trimming capability, connect a 0±
kW potentiometer between the plus and minus
outputs with the wiper arm connected to the
Vout trim pin.
The range for the external trim is about 0±%.
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±±.±0 (±±.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
C2023J5003AHF
90 Degree Hybrid Coupler, 2000MHz Min, 2300MHz Max, 0.4dB Insertion Loss-Max, HALOGEN FREE AND ROHS COMPLIANT, MINIATURE, SURFACE MOUNT PACKAGE-6
ANAREN
C2028.21.01
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 20, Conductor/Strands: Solid
GENERAL
C2028.21.03
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 20, Conductor/Strands: Solid
GENERAL
C2028.21.05
Hook-Up Wire, UL 1007, UL 1569, CSA TR-64, Gauge Size (AWG): 20, Conductor/Strands: Solid
GENERAL
©2020 ICPDF网 联系我们和版权申明