D217ERU [MPD]
Low Cost, 4:1 Input Miniature, 2W SIP DC/DC Converters; 低成本, 4 : 1输入微型, 2W SIP DC / DC转换器型号: | D217ERU |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Low Cost, 4:1 Input Miniature, 2W SIP DC/DC Converters |
文件: | 总2页 (文件大小:199K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
D200ERUSeries
Low Cost, 4:1 Input
Miniature, 2W SIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
Conditions
24 VDC Input
Min.
Typ.
24.0
48.0
Max.
36.0
72.0
1.0
Units
• 2W Output Power
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• Short Circuit Protected
• Miniature SIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
9.0
Input Voltage Range
VDC
48 VDC Input 18.0
Reverse Polarity Input Current
Short Circuit Input Power
Output
A
1,500
mW
Parameter
Conditions
Min.
Typ.
1.0
1.0
0.2
0.5
15
Max.
3.0
Units
%
• Industry Standard Pin-Out
• Low Low Cost!!
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
2.0
%
Vin = Min to Max
Iout = 10% to 100%
See Note 1
0.75
1.5
%
Load Regulation
Ripple (20 MHz)
%
30
mV P - P
mV P - P
%
Noise (20 MHz)
50
150
Output Power Protection
Temperature Coefficient
Output Short Circuit
General
120
0.03
%/°C
Continuous (Autorecovery)
RoHS Compliant
Parameter
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
MΩ
pF
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency , Single Output
Switching Frequency , Dual Output
Environmental
Parameter
65
Iout = 100%
Iout = 100%
100
200
650
400
kHz
kHz
Conditions
Min.
-40
Typ.
Max.
+85
Units
°C
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
+25
-55
+125
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Physical
Case Size
1.02 x 0.37 x 0.49 Inches (26.0 x 9.50 x 12.50 mm)
Non-Conductive Black Plastic (UL94-V0)
0.24 Oz (7.0g)
Case Material
Weight
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
1.0
MHours
Absolute Maximum Ratings
Parameter
Conditions
24 VDC Input
Min.
-0.7
-0.7
Max.
40.0
80.0
300
Units
Input Voltage Surge (1 Sec)
VDC
48 VDC Input
Lead Temperature
1.5 mm From Case For 10 Sec
All Models
°C
Internal Power Dissipation
1,800
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Fuse Rating
Slow-Blow
Input
Output
Model
Number
Efficiency
(%, Typ)
Voltage Current
Current
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
(VDC) (mA, Max) (mA, Min)
(mA)
500
500
500
500
500
500
500
500
500
200
200
200
200
200
200
200
200
200
D201ERU
D202ERU
D203ERU
D204ERU
D205ERU
D206ERU
D207ERU
D208ERU
D209ERU
D211ERU
D212ERU
D213ERU
D214ERU
D215ERU
D216ERU
D217ERU
D218ERU
D219ERU
24
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
48
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
114
111
107
102
103
110
107
102
103
58
35
35
35
35
35
35
35
35
35
15
15
15
15
15
15
15
15
15
3.3
5.0
9.0
500.0
400.0
222.0
167.0
133.0
200.0
111.0
83.0
50.0
40.0
22.0
16.0
13.0
20.0
11.0
8.0
73
75
78
82
81
76
78
82
81
72
76
78
81
80
75
77
81
80
12.0
15.0
5.0
9.0
12.0
15.0
3.3
67.0
7.0
500.0
400.0
222.0
167.0
133.0
200.0
111.0
83.0
50.0
40.0
22.0
16.0
13.0
20.0
11.0
8.0
55
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
53
51
52
55
54
51
52
67.0
7.0
Notes:
Derating Curve
1. When measuring output ripple, it is recommended that an external ceramic capacitor
(approx. 1 µF to 10 µF) be placed from the +Vout pin to the -Vout pin for single output
units and from each output to common for dual output units.
2. These units should not be operated with a load under 10% of full load. Operation at
no-load may cause damage to the unit.
3. These converters are specified for
operation without external compo-
Input
Capacitor
Output
Capacitor
nents. However, in some applica-
tions the addition of input/output
capacitors will enhance stability and
reduce output ripple. Recommended
capacitor values are given at right.
Output ripple on single output units
may be further enhanced by using
the CS terminal (single output units
operated at 50% load or below
Vin
Vout
12 VDC
15 VDC
24 VDC
48 VDC
100 µF
100 µF
10 µF
5 VDC
9 VDC
12 VDC
15 VDC
47 µF
47 µF
47 µF
47 µF
10 µF
should use this function). A low ESR capacitor is connected between the CS pin and the
-Vout pin (the capcitor anode connected to the -Vout pin). Recommended capacitor
values are given in the table at right. If not used, the CS pin should be left open.
4. Dual output units may be connected to provide a 10V, 24V or 30 VDC output. To do
this, connect the load across the +Vout and -Vout outputs and float the output com-
mon.
5. The remote on/off control pin is referenced to
the -Vin pin. Input current to the pin should
be between 5 - 10 mA with a maximum of 20
mA.
Min
<0.6 VDC to Open Circuit
2.7 VDC 15.0 VDC
Max
On
Off
6. It is recommended that a fuse be used on the
Mechanical Dimensions
input of a power supply for protection. See the Model Selection
table above for the correct rating.
Max. Capacitive Load
Output Voltage
3.3
820 µF
5
5
9
12
15
660 µF
9
470 µF
12
330 µF
15
220 µF
330 µF
220 µF
150 µF
120 µF
Pin Connections
Pin Single
Dual
Pin Single
Dual
1
2
3
6
-Vin
+Vin
Remote ON/OFF
+Vout +Vout
-Vin
+Vin
7
8
9
NC
NC
-Vout
Common
NC
-Vout
NC = No Connection
Mechanical Notes:
All dimensions are typical in inches (mm)
Tolerance x.xx = 0.01 ( 0.25)
MicroPower Direct
•
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com