E132 [MPD]
Isolated, Single Output Miniature, 1W SIP DC/DC Converters; 孤立的,单输出微型1W SIP DC / DC转换器型号: | E132 |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Isolated, Single Output Miniature, 1W SIP DC/DC Converters |
文件: | 总2页 (文件大小:154K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
E100Series
Isolated, Single Output
Miniature, 1W SIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 1W Output Power
Parameter
Conditions
Min.
4.5
Typ.
5.0
Max.
5.5
Units
VDC
A
5 VDC Input
12 VDC Input 10.8
24 VDC Input 21.6
48 VDC Input 43.2
12.0
24.0
48.0
13.2
26.4
52.8
0.3
• Miniature SIP Case
• 1,000 VDC Isolation
• Complies to RFI Standards
• >2 MHour MTBF
Input Voltage Range
Reverse Polarity Input Current
Input Filter
Internal Capacitor
Min.
• 20 Standard Models
• Industry Standard Pin-Out
Output
Parameter
Output Voltage Accuracy
Line Regulation
Conditions
Typ.
1.2
Max.
3.0
Units
%
For Vin Change of 1%
%
Load Regulation (Note 1)
Ripple & Noise (20 MHz) (Note 2)
Output Power Protection
Temperature Coefficient
Output Short Circuit
General
See Model Selection Guide
60
mV P - P
%
110
0.01
0.02
%/ºC
Momentary (0.5 Sec.)
RoHS Compliant
Parameter
Conditions
Min.
60 Seconds 1,000
1,000 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
MΩ
pF
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI/RFI
60
50
kHz
EN55022 A, EN55024 A, IEC 61000-4-2, IEC 61000-4-3, FCC 47 CFR Part 15 B
Environmental
Parameter
Conditions
Min.
-40
Typ.
+25
Max.
+85
Units
ºC
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
+100
+125
ºC
-40
ºC
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
MicroPower Direct
292 Page Street
Ste D
Stoughton, MA 02072
USA
Case Size (5V, 12V & 24V Input Models)
Case Size (48V Input Models)
Case Material
0.46 x 0.24 x 0.40 Inches (11.68 x 6.0 x 10.2 mm)
0.46 x 0.29 x 0.40 Inches (11.68 x 7.5 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.06 Oz (1.8g)
Weight
Reliability Specifications
Parameter
MTBF
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
Min.
2.0
Typ.
Typ.
Max.
Units
MIL HDBK 217F, 25ºC, Gnd Benign
MHours
Absolute Maximum Ratings
Parameter
Conditions
Min.
-0.7
-0.7
-0.7
-0.7
Max.
7.0
Units
VDC
5 VDC Input
12 VDC Input
15.0
28.0
54.0
260
650
Input Voltage Surge (1 Sec)
24 VDC Input
48 VDC Input
Lead Temperature
1.5 mm From Case For 10 Sec
All Models
ºC
Internal Power Dissipation
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Load
Regulation
(% Max)
10
Fuse Rating
Slow-Blow
(mA)
500
Input
Output
Voltage Current
(VDC) (mA, Max) (mA, Min)
Model
Number
Efficiency
(%, Typ)
Voltage (VDC)
Nominal
Current (mA)
Full-Load No-Load
Current
Range
E101
E102
E103
E104
E105
E111
E112
E113
E114
E115
E121
E122
E123
E124
E125
E131
E132
E133
E134
E135
5
5
5
5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
267
260
256
257
257
112
109
107
107
107
56
25
25
25
25
25
16
16
16
16
16
10
10
10
10
10
7
5.0
9.0
12.0
15.0
24.0
5.0
200.0
111.0
83.3
66.6
41.6
200.0
111.0
83.3
66.6
41.6
200.0
111.0
83.3
66.6
41.6
200.0
111.0
83.3
66.6
41.6
4.0
2.0
2.0
2.0
2.0
4.0
2.0
2.0
2.0
2.0
4.0
2.0
2.0
2.0
2.0
4.0
2.0
2.0
2.0
2.0
75
77
78
78
78
75
77
78
78
78
75
77
78
78
78
75
76
76
76
76
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
500
500
500
500
200
200
200
200
200
100
100
100
100
100
50
50
5
4.5 - 5.5
12
12
12
12
12
24
24
24
24
24
48
48
48
48
48
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
9.0
12.0
15.0
24.0
5.0
55
54
54
54
9.0
12.0
15.0
24.0
5.0
28
27
7
9.0
27
7
12.0
15.0
24.0
10
10
10
50
50
50
27
7
27
7
Models with other outputs
are available. Contact the
factory for details!!
Derating Curve
Notes:
1. Output load regulation is specified for a load change of
20% to 100%.
2. When measuring output ripple, it is recommended that
an external 0.33 µF ceramic capacitor be placed from the
+Vout pin to the -Vout pin.
3. Operation at no-load will not damage these units. How-
ever, they may not meet all specifications.
4. The 5V, 12V and 24V input units do not require external
components to operate, but the use of a low ESR capaci-
tor (approximately 10 uF, ESR <1.0Ω at 100 kHz) mounted
close to the converter input pins is recommended.
For 48 VDC input units, an input capacitor should always
be used. Dependent upon the application, a value be-
tween 4.7 µF and 47 uF should be sufficient.
5. It is recommended that a fuse be used on the input of
a power supply for protection. See the table above for
the correct rating.
Mechanical Dimensions
Pin Connections
Pin
Description
Capacitive
Load
1
-Vin
2
+Vin
(µF Max)
3
-Vout
220
4
+Vout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
• Pin 1 is marked by a “dot” or indentation on the side of the
unit
• Dimensions indicated on the drawing are as follows:
Input Voltage
Dimension
5, 12 & 24V
0.24 (6.0)
48V
“W”
“X”
0.29 (7.5)
0.08 (2.00)
0.05 (1.25)
MicroPower Direct
•
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com