G200RWSeries
Compact MiniDIP, 2W
Wide Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
Conditions
Min.
3.5
Typ.
4.0
Max.
4.5
Units
• 2W Output Power
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Short Circuit Protected
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input 16.0
4.5
8.0
7.0
12.0
24.0
9.0
18.0
36.0
Input Start Voltage
VDC
Input Filter
π (Pi) Filter
• Compact MiniDIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
Reverse Polarity Input Current
Short Circuit Input Power
Output
1.0
A
1,500
mW
• Industry Standard Pin-Out
Parameter
Conditions
Min.
Typ.
1.0
1.0
0.3
0.5
30
Max.
2.0
2.0
0.5
0.75
50
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
µSec
%
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Vin = Min to Max
Iout = 25% to 100%
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Response Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
Over Line, Load & Temp.
50% Load Step Change
75
15
120
100
3.0
0.01
300
5.0
0.02
RoHS Compliant
%/°C
Continuous (Autorecovery)
Parameter
Isolation Voltage
Conditions
Min.
Typ.
Max.
Units
VDC
VDC
MΩ
pF
60 Seconds 1,500
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Flash Tested For 1 Sec 1,650
1,000 VDC 1,000
100 kHz, 1V
250
300
420
kHz
Parameter
Conditions
Min.
-40
-40
Typ.
+25
+25
Max.
+65
+90
Units
°C
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-40
+125
°C
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
Case Material
0.94 x 0.54 x 0.30 Inches (23.8 x 13.7 x 7.62 mm)
Non-Conductive Black Plastic (UL94-V0)
0.18 Oz (5.1g)
Weight
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign 1,000
Min.
Typ.
Typ.
Max.
Units
kHours
Absolute Maximum Ratings
Parameter
Conditions
Min.
-0.7
-0.7
-0.7
-0.7
Max.
11.0
25.0
50.0
100.0
260
Units
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
Input Voltage Surge (1 Sec)
VDC
Lead Temperature
Internal Power Dissipation
1.5 mm From Case For 10 Sec
All Models
°C
mW
1,800
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Output
Voltage Current
(VDC) (mA, Max) (mA, Min)
Reflected
Ripple
Current (mA)
Fuse Rating
Slow-Blow
(mA)
Model
Efficiency
(%, Typ)
Voltage (VDC)
Number
Current (mA)
Full-Load No-Load
Current
Nominal
5
Range
G201RW
G202RW
G203RW
G204RW
G205RW
G206RW
G207RW
G211RW
G212RW
G213RW
G214RW
G215RW
G216RW
G217RW
G221RW
G222RW
G223RW
G224RW
G225RW
G226RW
G227RW
G231RW
G232RW
G233RW
G234RW
G235RW
G236RW
G237RW
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
471
548
534
582
667
615
598
184
217
209
220
242
224
226
96
109
109
108
119
112
110
49
40
40
40
40
40
40
40
20
20
20
20
20
20
20
10
10
10
10
10
10
10
8
3.3
5.0
12.0
15.0
5.0
12.0
15.0
3.3
500.0
400.0
1670
134.0
200.0
83.0
125.0
100.0
42.0
33.0
50.0
21.0
17.0
125.0
100.0
42.0
33.0
50.0
21.0
17.0
125.0
100.0
42.0
33.0
50.0
21.0
17.0
125.0
100.0
42.0
33.0
50.0
21.0
17.0
100
100
100
100
100
100
100
25
25
25
25
25
25
25
15
15
15
15
15
15
70
73
75
73
64
69
71
73
77
80
80
73
78
78
72
77
80
81
74
78
80
71
73
79
79
71
77
77
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
250
250
250
250
250
250
5
5
5
5
5
5
67.0
12
12
12
12
12
12
12
24
24
24
24
24
24
24
48
48
48
48
48
48
48
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
500.0
400.0
1670
134.0
200.0
83.0
5.0
12.0
15.0
5.0
12.0
15.0
3.3
67.0
500.0
400.0
1670
134.0
200.0
83.0
5.0
12.0
15.0
5.0
12.0
15.0
3.3
67.0
15
10
10
10
10
10
10
10
250
120
120
120
120
120
120
120
500.0
400.0
1670
134.0
200.0
83.0
57
53
55
62
57
57
8
8
8
8
8
8
5.0
12.0
15.0
5.0
12.0
15.0
67.0
Notes:
Derating Curve
1. When measuring output ripple, it is recommended that an external 0.47 µF ceramic
capacitor be placed from the +Vout pin to the -Vout pin for single output units and
from each output to common for dual output units. For noise sensitive applications,
the use of 3.3 µF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a load step change
of 75% to 100%.
3. Operation at no-load will not damage these units. However, they may not meet all
specifications.
4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output.
To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs
and float the output common.
5. The converter should be connected to a low ac-impedance source. An input source
with a highly inductive impedance may affect the stability of the converter. In ap-
plications where the converter output loading is high and input power is supplied
over long lines, it may be necessary to use a capacitor on the input to insure start-
up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor be
mounted close to the converter. For 5V input units a 8.2 µF is recommended, for
12V input units, a 3.3 µF; and for 24V & 48V units a 1.5 µF.
6. It is recommended that a fuse be used on the input of a power supply for protec-
tion. See the table above for the correct rating.
Mechanical Dimensions
Capacitive Load
Pin Connections
Output (VDC)
µF Max
Pin
Single
Dual
3.3
5.0
12.0
15.0
5.0
2,200
1,000
170
110
470
100
47
1
-Vin
-Vin
7
NC
NC
8
NC
Common
+Vout
-Vout
+Vin
9
+Vout
-Vout
+Vin
10
16
12.0
15.0
Note: For dual output units,
Cap load is given for each
output.
NC = No Connection
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
MicroPower Direct
•
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com