LDC-80 [MPD]
90W Output Power;型号: | LDC-80 |
厂家: | MICROPOWER DIRECT, LLC |
描述: | 90W Output Power |
文件: | 总4页 (文件大小:1094K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
LDC-80
Compact, LED, 90W
Constant Current
AC/DC Power Supply
Electrical Specifications
Key Features:
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 90W Output Power
Input
Parameter
Conditions
Min.
90
127
47
Typ.
Max.
305
431
63
Units
VAC
VDC
Hz
• UL 8750 Approved
Input Voltage Range
• Constant Current Output
• Active PFC
Input Frequency
Inrush Current, See Note 1
230 VAC
115 VAC
230 VAC
264 VAC
75
A Pk
• 90 - 305 VAC Input
1.10
0.55
0.50
Input Current
A
• IP65 / IP67 Rated
• Meets EN 55015, EN 61547
• Dimming Function
0.98 @ 115 VAC
0.96 @ 230 VAC
0.94 @ 264 VAC
Power Factor Correction
• >50 kHour Life Expectancy
• Lightning Surge Protection
• Over Volt/Temp Protection
Total Harmonic Distortion (THD)
Turn On Delay, See Note 3
See Note 2
20
%
S
115 VAC
230 VAC
277 VAC
1.0
0.5
Leakage Current
0.75
mA
Output
Parameter
Conditions
Min.
Typ.
5.0
1.0
1.0
5.0
Max.
Units
%
%
V P-P
%
mS
°C
Output Current Accuracy
Line Regulation
Ripple & Noise (20 MHz)
Output Ripple Current
Hold-Up Time
VIN = Min to Max
See Note 4
115 VAC 16.0
10%, Autorecovery
Continuous
Over Temperature Protection
Short Circuit Protection, See Note 5
Overload Protection
General
85
Autorecovery
95
107
%IOUT
Units
VAC
Parameter
Conditions
Min.
Typ.
Max.
Input to Output 3,750
Isolation Voltage, 60S
Insulation Resistance
Input to FG 2,000
Output to FG
Input to Output
500
Input to FG 100 Mꢀ / 500 VDC / 25°C / 70% RH
Output to FG
EMI Characteristics
Parameter
Standard
EMI
EMS
Surge
EN 55015; EN 6100-3-2, -3; FCC Part 18; CNS 14115; GB 17743
EN 61547; EN 61000-4-2,-3, -4, -5, -6, -8, -11; GB 17625.1
10 kV (L/N - FG), 5 kV (L-N)/1.2 x 50 µS
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
Min.
-40
-40
Typ.
+25
Max.
+70
+85
Units
°C
°C
Ambient
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing 95
Humidity
%
Physical
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Case Size
See Mechanical Diagrams (Page 4)
32.1 Oz (950g)
Weight
Reliability Specifications
Parameter
MTBF
Life Expectancy
Safety Standards
Vibration
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
220
50
Typ.
Max.
Units
kHours
kHours
See Note 6
UL 8750 Approved, Meets EN 61347, GB 19510.1, GB 19510.14
5 - 500 Hz, 1G , 1 Oct/Min, 2 Cycles, Period for 75 Min. Each Along X, Y, & Z Axis
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Notes:
Output
1. Inrush current is given for a cold start
at 25°C.
2. Total Harmonic Distortion (THD) is
specified with an input of 230 VAC/50
Hz at full load.
Output
Power
(W)
Model
Efficiency
(%, Typ)
Current
Adj. Range (mA)
Voltage
OVP Level
(VDC)
Number
Range (VDC)
Max (mA)
350
LDC-80-0350 x
LDC-80-0700 x
LDC-80-1400 x
LDC-80-1750 x
LDC-80-2100 x
LDC-80-2450 x
210 - 350
420 - 700
128 - 257
64 - 129
37 - 58
32 - 49
32 - 42
21 - 35
260 - 310
156 - 190
62 - 74
90
90
82
86
88
86
91
91
90
90
90
90
3. Turn on delay is specified at full load.
4. Ripple & noise is measured at 20 MHz.
Connectiontotheunitismadewitha0.1µF
ceramic capacitor and a 22 µF electrolytic
capacitor connected in parallel.
5. If a short circuit fault occurs, the protection
circuit will latch off the output. A power
reset is required to recover.
6. Life expectancy is calculated at 230 VAC,
full load and a case temp of +70°C.
7. Ifanovervoltagefaultoccurs,theprotection
circuit will latch off the output. A power
reset is required to recover.
700
1,400
1,750
2,100
2,450
840 - 1,400
1,050 - 1,750
1,260 - 2,100
1,470 - 2,450
55 - 65
48 - 55
41 - 50
Package Type
Model
LDC-80-xxxx A
LDC-80-xxxx B
Ingress Protection
Dimming Function
IP65
IP67
Adjust by internal, variable resistor
Adjust by external resistor, DC voltage level or PWM signal
Derating Curve: Temperature
Derating Curve: Input Voltage
Efficiency vs Load: LDC-80-700
PFC vs Load: LDC-80-700
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com
Functional Block Diagram
Dimming Mode: B Model
With the LDC-80 “B” model, the output current level can be adjusted (Dimmed) by three different methods; Resistive, Analog or
Digital. Adjustments are made using the +DIM and -DIM inputs.
Resistive: Connect a 0.1 to 10 kꢀ resistor between the DIM+ (Blue) and DIM- (White) wires
Input Frequency
10 kꢀ
20 kꢀ
30 kꢀ
40 kꢀ
50 kꢀ
60 kꢀ
70 kꢀ
80 kꢀ
90 kꢀ
100 kꢀ
Open
Percentage of Rated Current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95~105%
Analog: Apply 1 VDC to 10 VDC level between the DIM+ (Blue) and DIM- (White) wires
Adjust Voltage
1 VDC
10%
2 VDC
20%
3 VDC
30%
4 VDC
40%
5 VDC
50%
6 VDC
60%
7 VDC
70%
8 VDC
80%
9 VDC
90%
10 VDC
100%
Open
Percentage of Rated Current
95~105%
Digital: Apply a PWM signal (100 Hz - 3 kHz) between the DIM+ (Blue) and DIM- (White) wires
Duty Cycle
10%
10%
20%
20%
30%
30%
40%
40%
50%
50%
60%
60%
70%
70%
80%
80%
90%
90%
100%
100%
Open
Percentage of Rated Current
95~105%
Notes:
1. The -DIM (White) and -LED (Black) wires should not be connected.
2. The Dimming function will not turn the lighting fixture totally off. For more info on how to do this, please contact the factory
MicroPower Direct
• 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
Mechanical Dimensions: A Model
www.micropowerdirect.com
Wire Connections: Input
Wire Connections: Output
Color
Function
Color
Function
Green/Yellow
Brown
Field Ground
AC-Line
Black
Red
-LED
+LED
Blue
AC-Neutral
Mechanical Dimensions: B Model (Dimming Function)
Wire Connections: Input
Wire Connections: Output
Color
Function
Color
Function
Green/Yellow
Brown
Field Ground
AC-Line
White
Blue
-DIM
+DIM
Blue
AC-Neutral
Black
Red
-LED
+LED
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
LDC-N5612NI
0.56 QUAD DIGIT CLOCK DISPLAY, 565mm GREEN, COMMON CATHODE, GREY FONT/WHITE SEGMENT
LUMEX
LDC0150
Electric Fuse, Time Delay Blow, 150A, 600VAC, 600VDC, 200000A (IR), Inline/holder,
LITTELFUSE
LDC0200
Electric Fuse, Time Delay Blow, 200A, 600VAC, 600VDC, 200000A (IR), Inline/holder,
LITTELFUSE
©2020 ICPDF网 联系我们和版权申明