LF100DI [MPD]
High Isolation, 1W Dual Output SMT DC/DC Converters; 高隔离, 1W双输出SMT DC / DC转换器型号: | LF100DI |
厂家: | MICROPOWER DIRECT, LLC |
描述: | High Isolation, 1W Dual Output SMT DC/DC Converters |
文件: | 总2页 (文件大小:210K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
LF100DISeries
High Isolation, 1W
Dual Output SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min.
Typ.
5.0
Max.
5.5
Units
VDC
A
Key Features:
5 VDC Input
4.5
• 1W Output Power
• Ultra-Miniature SMT Case
• 3,000 VDC Isolation
Input Voltage Range
12 VDC Input 10.8
24 VDC Input 21.6
12.0
24.0
13.2
26.4
0.3
Reverse Polarity Input Current
Input Filter
• 5V, 12V & 24V Inputs
Capacitor
• -40ºC to +85ºC Operation
• 9 Standard Models
Output
Parameter
Conditions
Min.
Typ.
1.5
0.1
1.2
Max.
4.0
Units
%
• 2.0 MH MTBF Minimum
• Industry Standard Pin-Out
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Balanced Loads
1.0
%
For Vin Change of 1%
1.5
%
Load Regulation (Note 1)
Ripple & Noise (20 MHz) (Note 2)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
General
See Model Selection Guide
75
100
150
5
mV P - P
mV P - P
mv rms
%
Over Line, Load & Temp.
120
0.01
0.02
%/ºC
Momentary (0.5 Sec.)
RoHS Compliant
Parameter
Conditions
Conditions
Min.
Typ.
Max.
Units
VDC
GΩ
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
60 Seconds 3,000
500 VDC
10
100 kHz, 1V
60
100
150
pF
50
100
kHz
Min.
-40
Typ.
Max.
+85
Units
ºC
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
+25
-40
+90
ºC
-40
+125
ºC
Free Air Convection
RH, Non-condensing
MicroPower Direct
292 Page Street
Suite D
Humidity
95
%
Physical
Case Size
0.60 x 0.31 x 0.26 Inches (15.24 x 8.0 x 6.7 mm)
Molded Black Plastic (UL94-V0)
0.07 Oz (2.2g)
Stoughton, MA 02072
USA
Case Material
Weight
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign
2.0
MHours
Absolute Maximum Ratings
Parameter
Conditions
5 VDC Input
Min.
-0.7
-0.7
-0.7
Max.
9.0
Units
Input Voltage Surge (1 Sec)
12 VDC Input
18.0
30.0
300
550
VDC
24 VDC Input
Lead Temperature
1.5 mm From Case For 10 Sec.
All Models
ºC
Internal Power Dissipation
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Output
Load
Regulation
(%, Max)
Fuse Rating
Slow-Blow
(mA)
Model
Number
Efficiency
(%, Typ)
Voltage (VDC)
Current (mA)
Voltage Current
(VDC) (mA, Max) (mA, Min)
Current
Nominal
Range
Full-Load No-Load
LF101DI
LF102DI
LF103DI
LF111DI
LF112DI
LF113DI
LF121DI
LF122DI
LF123DI
Notes:
5
4.5 - 5.5
277
255
258
112
105
104
57
30
30
30
12
12
12
7
5.0
12.0
15.0
5.0
100.0
42.0
34.0
100.0
42.0
34.0
100.0
42.0
34.0
2.0
0.8
0.7
2.0
0.8
0.7
2.0
0.8
0.7
10
7
72
78
79
74
80
81
72
79
80
500
500
500
200
200
200
100
100
100
5
4.5 - 5.5
5
4.5 - 5.5
7
12
12
12
24
24
24
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
8
12.0
15.0
5.0
5
5
8
53
7
12.0
15.0
5
53
7
5
Derating Curve
1. Load regulation is measured for an output change of 20% to
100%.
2. When measuring output ripple, it is recommended that an external
0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout
pin. For noise sensitive applications, the use of 0.47 µF capacitors will
reduce the output ripple.
3. Operation at no-load will not damage these units. However, they
may not meet all specifications.
4. The converter should be connected to a low ac-impedance source.
An input source with a highly inductive impedance may affect the
stability of the converter. In applications where the converter output
loading is high and input power is supplied over long lines, it may
be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz)
capacitor be mounted close to the converter. For 5V input units a 2.2
µF is recommended, for 12V input units, a 1.0 µF, and for 24V input
units, a 0.47 µF.
5. Dual output units may be connected to provide a 10 VDC, 24 VDC or
30 VDC output. To do this, connect the load across the positive (+Vout)
and negative (-Vout) outputs and float the output common.
6. It is recommended that a fuse be used on the input of a power supply
for protection. See the table above for the correct rating.
Mechanical Dimensions
Board Layout
Pin Connections
Pin
1
Description
-Vin
Pin Description
7
NA
2
+Vin
8
+Vout
NA
3
NA
10
11
12
5
Common
-Vout
NA
6
NA
NA = Not available for connection
Capacitive Load
5V Out
µF Max
12 & 15V Out
µF Max
10
2.2
Notes:
• All dimensions are typical in inches (mm)
• Tolerance: Inches x.xx = 0.01
Millimeters x.x =
x.xx = 0.13
Pin: 0.002 ( 0.05)
0.25
MicroPower Direct• Pin 1 is marked by a “dot” or indentation
on the unit. The curved edge of the case
indicates the Pin 1 side.
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
©2020 ICPDF网 联系我们和版权申明