MA1012S15RW [MPD]

MA1000RW SERIES;
MA1012S15RW
型号: MA1012S15RW
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

MA1000RW SERIES

文件: 总2页 (文件大小:244K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MA1000RWSeries  
2:1 Input Range, 10W  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Conditions  
Min.  
9.0  
Typ.  
12.0  
24.0  
48.0  
Max.  
18.0  
36.0  
75.0  
Units  
VDC  
Key Features:  
12 VDC Input  
10W Output Power  
Input Voltage Range  
24 VDC Input 18.0  
48 VDC Input 36.0  
(Pi) Filter (Meets EN 55022 Class “A”)  
2:1 Input Voltage Range  
Compact DIP Case  
Input Filter  
Input Reflected Ripple Current  
Output  
Parameter  
Output Voltage Accuracy  
35.0  
mA P - P  
1,500 VDC I/O Isolation  
Meets EN 55022 “A”  
Single & Dual Outputs  
Wide Temperature Operation  
Industry Standard Pin-Out  
Conditions  
VIN = Min to Max  
Min.  
Typ.  
1.0  
Max.  
Units  
%
%
Line Regulation  
0.5  
0.5  
1.0  
5.0  
75  
Single Output  
Dual Output  
See Note 2  
See Note 3  
Load Regulation, See Note 1  
%
Cross Regulation, Dual Output  
Ripple & Noise (20 MHz)  
Output Power Protection  
Temperature Coefficient  
Output Short Circuit Protection  
General  
%
mV P - P  
% IOUT  
%/ºC  
150  
0.02  
Continuous (Autorecovery)  
Parameter  
Conditions  
Min.  
3 Seconds 1,500  
3 Seconds 1,000  
500 VDC 1,000  
100 kHz/1V  
Typ.  
Max.  
Units  
Isolation Voltage (Input/Output)  
Isolation Voltage (Case/Input, Output)  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
EMI Characteristics  
Parameter  
VDC  
M⍀  
pF  
kHz  
1,000  
330  
Standard  
Level  
Radiated Emissions  
Conducted Emissions, See Note 4  
ESD  
EN 55022  
EN 55022  
Class A  
Class A  
EN 61000-4-2  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-8  
Criteria B  
Criteria A  
Criteria B  
Criteria B  
Criteria A  
Criteria A  
RS  
EFT, See Note 4  
Surge, See Note 4  
CS  
PFMF  
Environmental  
Parameter  
Conditions  
Min.  
-40  
Typ.  
Max.  
+85  
+100  
+125  
Units  
ºC  
ºC  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Ambient  
Case  
-40  
ºC  
Free Air Convection  
RH, Non-condensing  
Humidity  
95  
%
Physical  
Case Size  
Case Material  
MicroPower Direct  
292 Page Street  
Suite D  
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)  
Copper With Nickel Coating (UL94V-0)  
0.60 Oz (17g)  
Weight  
Reliability Specifications  
Parameter  
Stoughton, MA 02072  
USA  
Conditions  
Min.  
1.0  
Typ.  
Typ.  
Max.  
Units  
MHours  
MTBF  
MIL HDBK 217F, 25ºC, Gnd Benign  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Max.  
25.0  
50.0  
100.0  
260  
Units  
VDC  
ºC  
12 VDC Input -0.7  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
Lead Temperature  
1.5 mm From Case For 10 Sec  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Over  
Max  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Number  
Voltage Capacitive Efficiency  
Voltage (VDC)  
Current (mA)  
Voltage Current  
Current  
Protection  
(mA, Max) (mA, Min)  
(VDC)  
Load  
(%, Typ)  
(VDC)  
Nominal  
Range  
Full-Load No-Load  
(µF Max)  
MA1012S-02RW  
MA1012S-03RW  
MA1012S-05RW  
MA1012S-12RW  
MA1012S-15RW  
MA1012D-12RW  
MA1012D-15RW  
MA1024S-02RW  
MA1024S-03RW  
MA1024S-05RW  
MA1024S-12RW  
MA1024S-15RW  
MA1024D-12RW  
MA1024D-15RW  
MA1048S-02RW  
MA1048S-03RW  
MA1048S-05RW  
MA1048S-12RW  
MA1048S-15RW  
MA1048D-12RW  
MA1048D-15RW  
12  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
48  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
9.0 - 18.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
791  
1,006  
992  
980  
958  
980  
969  
381  
497  
479  
485  
485  
485  
474  
191  
249  
242  
245  
242  
245  
245  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
2.5  
3.3  
5.0  
12.0  
15.0  
12.0  
15.0  
2.5  
3,000  
3,000  
2,000  
833  
667  
416  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
3.9  
3.9  
6.2  
15.0  
18.0  
15.0  
18.0  
3.9  
2,200  
2,200  
2,200  
820  
470  
220  
81  
84  
86  
87  
89  
87  
88  
84  
85  
89  
88  
88  
88  
90  
84  
85  
88  
87  
88  
87  
87  
2,500  
2,500  
2,500  
2,500  
2,500  
2,500  
2,500  
1,200  
1,200  
1,200  
1,200  
1,200  
1,200  
1,200  
750  
750  
750  
750  
750  
750  
750  
333  
150  
3,000  
3,000  
2,000  
833  
667  
416  
2,200  
2,200  
2,200  
820  
470  
220  
3.3  
5.0  
3.9  
6.2  
12.0  
15.0  
12.0  
15.0  
2.5  
3.3  
5.0  
12.0  
15.0  
12.0  
15.0  
15.0  
18.0  
15.0  
18.0  
3.9  
3.9  
6.2  
15.0  
18.0  
15.0  
18.0  
333  
150  
3,000  
3,000  
2,000  
833  
667  
416  
2,200  
2,200  
2,200  
820  
470  
220  
333  
150  
Notes:  
Derating Curve  
1. Load regulation is specified for a load change of ±% to 1±±%. Load regulation for 3.3V output models  
is 1.±% max for a load change of ±% to 1±±%.  
2. When measuring cross regulation, the load on one output is varied from 25% to 1±±% while the other  
output is held at 1±±%.  
3. When measuring output ripple, it is recommended that an external 1.± µF ceramic capacitor be placed  
from the +VOUT pin to the -VOUT pin for single output units and from each output to common for dual  
output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple.  
4. To help meet conducted emissions requirements, the Pi filter components (C1, & L1) in the diagram  
below should be used. These components should be mounted as close to the module as possible.  
To meet the requirements of EN 61±±±-4-4 and EN 61±±±-4-5, an external filter capacitor (C2 in the  
diagram below) is required.  
5. Operation at no-load will not damage these units. However, they may not meet all specifications.  
6. Dual output units may be connected to provide a 24 VDC or 3± VDC output. To do this, connect the  
load across the positive (+VOUT) and negative (-VOUT) outputs and float the output common.  
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table  
above for the correct rating.  
Recommended Input Components  
Mechanical Dimensions  
Pin Connections  
Pin  
2
Single  
-VIN  
Dual  
-VIN  
3
-VIN  
-VIN  
9
No Pin  
NC  
+VOUT  
-VOUT  
+VIN  
Common  
-VOUT  
+VOUT  
Common  
+VIN  
11  
14  
16  
22  
23  
+VIN  
+VIN  
NC: No Connection  
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = ±±.±2 (±±.5±)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MA10152D

Rectifier Diode, 1 Element, 0.15A, 80V V(RRM), Silicon
PANASONIC

MA10152E

Rectifier Diode, 1 Element, 0.15A, 80V V(RRM), Silicon
PANASONIC

MA10152F

Rectifier Diode, 1 Element, 0.1A, 80V V(RRM), Silicon,
PANASONIC

MA10152K

Rectifier Diode, 1 Element, 0.1A, 80V V(RRM), Silicon
PANASONIC

MA101A100FAA

Molded Axial Gen MLCC
KYOCERA AVX

MA101A100JAA

CAP CER 10PF 100V C0G/NP0 AXIAL
KYOCERA AVX

MA101A100JAA-BULK

CAP CER 10PF 100V C0G/NP0 AXIAL
KYOCERA AVX

MA101A100KAA

Molded Axial Gen MLCC
KYOCERA AVX

MA101A100MAA

Molded Axial Gen MLCC
KYOCERA AVX

MA101A101FAA

Molded Axial Gen MLCC
KYOCERA AVX

MA101A101FAA-BULK

CAP CER 100PF 100V NP0 AXIAL
KYOCERA AVX

MA101A101GAA

CAP CER 100PF 100V NP0 AXIAL
KYOCERA AVX