MA1212D-15RW [MPD]

2:1 Input Range, 12W Single & Dual Output DC/DC Con vert ers;
MA1212D-15RW
型号: MA1212D-15RW
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

2:1 Input Range, 12W Single & Dual Output DC/DC Con vert ers

文件: 总3页 (文件大小:379K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MA1200RWSeries  
2:1 Input Range, 12W  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Conditions  
Min.  
9.0  
Typ.  
12.0  
24.0  
48.0  
20  
Max.  
18.0  
36.0  
72.0  
Units  
VDC  
Key Features:  
12 VDC Input  
12W Output Power  
Input Voltage Range  
24 VDC Input 18.0  
48 VDC Input 36.0  
2:1 Input Voltage Range  
Compact DIP Case  
Start Up Time  
Input Filter  
Nominal VIN & Constant Resistive Load  
(Pi) Filter  
mS  
1,600 VDC I/O Isolation  
Meets EN 55032 “A”  
Single & Dual Outputs  
Remote On/Off Control  
Wide Temperature Operation  
Industry Standard Pin-Out  
Input Reflected Ripple Current  
Output  
Parameter  
Output Voltage Accuracy  
Line Regulation  
20.0  
mA P - P  
Conditions  
VIN = Min to Max  
Min.  
Typ.  
1.2  
Max.  
Units  
%
%
0.5  
0.5  
1.0  
Single Output  
Dual Output  
See Note 3  
See Note 4  
Load Regulation, See Note 2  
%
Cross Regulation, Dual Output  
Ripple & Noise (20 MHz)  
Transient Recovery Time, See Note 5  
Transient Response Deviation  
Output Power Protection  
Temperature Coefficient  
Output Short Circuit Protection  
General  
5.0  
%
mV P - P  
µSec  
%
% IOUT  
%/ºC  
85  
250  
25% Load Step Change  
3.0  
150  
0.02  
Continuous (Autorecovery)  
Parameter  
Conditions Min. Typ.  
Max.  
Units  
Input/Output, 60 Seconds 1,600  
Case/Input, Output, 60 Seconds 1,600  
500 VDC  
Isolation Voltage  
VDC  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Remote On/Off (See Page 3)  
Parameter  
Supply On  
Supply Off  
Standby Input Current  
Control Common  
Environmental  
1,000  
1,200  
330  
M⍀  
pF  
kHz  
100 kHz/1V  
Conditions  
See Note On Page 3  
Min.  
3.0  
0.0  
Typ.  
Max.  
12  
1.2  
Units  
VDC  
VDC  
mA  
5.0  
Referenced to -Input (Pins 2, 3)  
Parameter  
Conditions  
Min.  
-40  
Typ.  
Max.  
+85  
+100  
+125  
Units  
ºC  
ºC  
Ambient  
Case  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Humidity  
-40  
ºC  
Free Air Convection  
RH, Non-condensing  
95  
%
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Physical  
Case Size  
Case Material  
Weight  
Reliability Specifications  
Parameter  
See Mechanical Diagram (Page 3)  
Copper With Nickel Coating (UL94V-0)  
0.63 Oz (18g)  
Conditions  
Min.  
1.0  
Typ.  
Typ.  
Max.  
Units  
MHours  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
MTBF  
MIL HDBK 217F, 25ºC, Gnd Benign  
Absolute Maximum Ratings  
Parameter  
Conditions  
12 VDC Input  
24 VDC Input  
48 VDC Input  
1.5 mm From Case For 10 Sec  
Min.  
Max.  
36.0  
50.0  
100.0  
260  
Units  
VDC  
ºC  
Input Voltage Surge (1 Sec)  
Lead Temperature  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Over  
Max  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Number  
Voltage Capacitive Efficiency  
Voltage (VDC)  
Current (mA)  
Full-Load No-Load  
Voltage Current  
Current  
Protection  
(mA, Max) (mA, Min)  
(VDC)  
Load  
(%, Typ)  
(VDC)  
Nominal  
12  
Range  
(µF Max)  
MA1212S-02RW  
MA1212S-03RW  
MA1212S-05RW  
MA1212S-12RW  
MA1212S-15RW  
MA1212D-12RW  
MA1212D-15RW  
MA1224S-02RW  
MA1224S-03RW  
MA1224S-05RW  
MA1224S-12RW  
MA1224S-15RW  
MA1224D-12RW  
MA1224D-15RW  
MA1248S-02RW  
MA1248S-03RW  
MA1248S-05RW  
MA1248S-12RW  
MA1248S-15RW  
MA1248D-12RW  
MA1248D-15RW  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
889  
1,146  
1,163  
1,149  
1,149  
1,149  
1,136  
445  
573  
581  
575  
575  
575  
562  
225  
283  
291  
294  
291  
294  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
2.5  
3.3  
5.0  
12.0  
15.0  
12.0  
15.0  
2.5  
3,500  
3,500  
2,400  
1,000  
800  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
3.9  
3.9  
6.2  
15.0  
18.0  
15.0  
18.0  
3.9  
2,000  
2,000  
2,000  
430  
300  
200  
85  
87  
89  
90  
90  
90  
91  
85  
87  
89  
90  
90  
90  
91  
84  
88  
89  
88  
89  
88  
89  
2,500  
2,500  
2,500  
2,500  
2,500  
2,500  
2,500  
1,200  
1,200  
1,200  
1,200  
1,200  
1,200  
1,200  
750  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
500  
400  
120  
3,500  
3,500  
2,400  
1,000  
800  
2,000  
2,000  
2,000  
430  
300  
200  
3.3  
5.0  
3.9  
6.2  
12.0  
15.0  
12.0  
15.0  
2.5  
3.3  
5.0  
12.0  
15.0  
12.0  
15.0  
15.0  
18.0  
15.0  
18.0  
3.9  
3.9  
6.2  
15.0  
18.0  
15.0  
18.0  
500  
400  
120  
3,500  
3,500  
2,400  
1,000  
800  
2,000  
2,000  
2,000  
430  
300  
200  
750  
750  
750  
750  
750  
750  
48  
48  
48  
48  
500  
400  
291  
120  
Notes:  
1. The specified maximum capacitive load is for each output.  
2. Load regulation is specified for a load change of 0% to 100%. Load regulation for 3.3V output models is 1.0% max for a load  
change of 0% to 100%.  
3. When measuring cross regulation, the load on one output is varied from 25% to 100% while the other output is held at 100%.  
4. Output ripple is measured with a 1.0 µF capacitor connected from the +VOUT to the -VOUT pins for single output units and from each output  
to common for dual output models. See the typical connection diagram & notes on page 3.  
5. Transient recovery is measured to within a 1% error band for a load step change of 75% to 50% to 25%.  
6. Operation at no-load will not damage these units. However, they may not meet all specifications.  
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.  
MPD offers a wide range of DC/DC convert-  
ers in the standard 24 pin DIP package. Mod-  
els range from 1W to 15W and offer wide input  
ranges, high isolation & tight regulation. Many  
are approved to EN 60950. For full information,  
go to our website or contact the factory.  
Temperature Derating Curve  
Efficiency vs Output Load: 12 VIN Models  
Efficiency vs Output Load: 48 VIN Models  
Efficiency vs Output Load: 24 VIN Models  
Page 2  
We Power Your Success - For Less  
www.micropowerdirect.com  
Typical Connection  
To help meet conducted emissions requirements, the filter components  
(C2, & L1) in the diagram above should be used. The recommended  
values are 100 µF/100V for C2 and 12 µH for L1. These components  
should be mounted as close to the module as possible. To meet the  
requirements of EN 61000-4-5, an external filter capacitor (C1 in the dia-  
gram above) is required.The recommended value for C1 is 330 µF/100V.  
EMI Characteristics  
Parameter  
Radiated Emissions  
Conducted Emissions  
ESD  
RS  
EFT  
Surge  
CS  
Standard  
EN 55032  
Criteria/Level  
Class A  
Class A  
EN 55032  
EN 61000-4-2  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-8  
B
A
A
A
A
A
When measuring output ripple, it is recommended that an external 1.0  
µF ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for  
single output units and from each output to common for dual output  
units. For noise sensitive applications, the use of 3.3 µF capacitors will  
reduce the output ripple.  
PFM  
The Remote On/Off circuit is referenced to the minus input of the unit  
(pins 2 & 3). If the On/Off input (pin 1) is connected to the minus input,  
the unit is shut off. If pin 1 is left open, the unit operates normally.  
Mechanical Dimensions  
Pin Connections  
Pin  
1
Single  
Dual  
Remote On/Off Remote On/Off  
2
3
-VIN  
-VIN  
-VIN  
-VIN  
9
No Pin  
NC  
+VOUT  
-VOUT  
+VIN  
Common  
-VOUT  
+VOUT  
Common  
+VIN  
11  
14  
16  
22  
23  
+VIN  
+VIN  
NC: No Connection  
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.02 ( 0.50)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MA1212S-02RW

2:1 Input Range, 12W Single & Dual Output DC/DC Con vert ers
MPD

MA1212S-03RW

2:1 Input Range, 12W Single & Dual Output DC/DC Con vert ers
MPD

MA1212S-05RW

2:1 Input Range, 12W Single & Dual Output DC/DC Con vert ers
MPD

MA1212S-12RW

2:1 Input Range, 12W Single & Dual Output DC/DC Con vert ers
MPD

MA1212S-15RW

2:1 Input Range, 12W Single & Dual Output DC/DC Con vert ers
MPD

MA1212XD-1W

1W/2W, FIXED INPUT , ISOLA TED & REGULATED DUAL OUTPUT DC-DC CONVERTER
MICRODC

MA1212XD-2W

1W/2W, FIXED INPUT , ISOLA TED & REGULATED DUAL OUTPUT DC-DC CONVERTER
MICRODC

MA1212XD-3W

1000VDC Isolated 3WDual&single output DIP24 Converters
MICRODC

MA1215XD-1W

1W/2W, FIXED INPUT , ISOLA TED & REGULATED DUAL OUTPUT DC-DC CONVERTER
MICRODC

MA1215XD-2W

1W/2W, FIXED INPUT , ISOLA TED & REGULATED DUAL OUTPUT DC-DC CONVERTER
MICRODC

MA1215XD-3W

1000VDC Isolated 3WDual&single output DIP24 Converters
MICRODC

MA121H

Rectifier Diode, 3 Element, 0.1A, Silicon
PANASONIC