MA124D24RU [MPD]
MA100RU SERIES;型号: | MA124D24RU |
厂家: | MICROPOWER DIRECT, LLC |
描述: | MA100RU SERIES |
文件: | 总4页 (文件大小:1468K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MA100RU Series
Wide 4:1 Input, 1.5W,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 1.5W Output Power
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• 20 Standard Models
• High Efficiency
Parameter
Conditions
24 VDC Input
Min.
Typ.
24.0
48.0
35
Max.
36.0
72.0
Units
VDC
9.0
Input Voltage Range
48 VDC Input 18.0
Input Reflected Ripple Current
Input Filter
mA P - P
ꢀ (Pi) Filter
Output
Parameter
• Compact DIP Case
• -40°C to +85°C Operation
• Metal Case Available
• Low Cost
Conditions
Min.
Typ.
1.0
0.5
0.5
0.5
60
Max.
Units
%
Output Voltage Accuracy
Line Regulation
VIN = Min to Max
IOUT = 25% to 100%
See Note 1
%
Load Regulation
%
Cross Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
General
%
See Note 2
mV P - P
%/°C
0.02
Alternate
Pin-Out
Continuous (Autorecovery)
Available
Parameter
Conditions
Min.
3 Seconds 1,500
500 VDC 1,000
Typ.
Max.
Units
VDC
M
Isolation Voltage, See Note 3
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
1.5 kV Isolation
Models
100 kHz/0.1V
60
pF
100
400
kHz
Available
Conditions
Min.
Typ.
Max.
+85
Units
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-40
+25
+100
+125
°C
-40
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Non-Conductive Black Plastic (UL94-V0)
0.44 Oz (12.5g)
Case Material, Plastic
Weight, Plastic Case
Case Material, Metal
Weight, Metal Case
Reliability Specifications
Parameter
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Nickel-Coated Copper With Non-Conductive Base (UL94-V0)
0.53 Oz (15g)
Conditions
Min.
Typ.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
1.0
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Absolute Maximum Ratings
Parameter
Conditions
Min.
Max.
40.0
80.0
260
Units
VDC
°C
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Fuse
Reflected
Capacitive
Load
Model
Number
Efficiency
(%, Typ)
Ripple
Rating
Voltage (VDC)
Current (mA)
Full-Load No-Load
Current
(mA Typ)
Voltage Current
Current
Slow-Blow
(mA)
(µF, Max)
(VDC)
(mA, Max) (mA, Min)
Nominal
24
Range
MA124S-05RU-xx
MA124S-09RU-xx
MA124S-12RU-xx
MA124S-15RU-xx
MA124S-24RU-xx
MA124D-05RU-xx
MA124D-09RU-xx
MA124D-12RU-xx
MA124D-15RU-xx
MA124D-24RU-xx
MA148S-05RU-xx
MA148S-09RU-xx
MA148S-12RU-xx
MA148S-15RU-xx
MA148S-24RU-xx
MA148D-05RU-xx
MA148D-09RU-xx
MA148D-12RU-xx
MA148D-15RU-xx
MA148D-24RU-xx
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
91.0
89.0
86.0
86.0
88.0
94.0
91.0
89.0
89.0
90.0
44.0
43.0
42.0
42.0
43.0
45.0
44.0
43.0
43.0
44.0
20
20
20
20
30
20
20
20
20
30
10
10
10
10
10
10
10
10
10
10
5.0
9.0
300.0
167.0
125.0
100.0
62.5
100.0
55.7
41.7
33.3
20.8
50.0
27.8
20.8
16.7
10.3
100.0
55.7
41.7
33.3
20.8
50.0
27.8
20.8
16.7
10.3
68
70
72
72
71
66
68
70
70
69
70
72
74
74
72
68
70
72
72
71
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
2,200
470
200
200
200
200
200
200
200
200
200
200
100
100
100
100
100
100
100
100
100
100
24
24
12.0
15.0
24.0
5.0
470
24
470
24
220
24
150.0
83.3
1,000
220
220
220
100
2,200
470
24
9.0
24
12.0
15.0
24.0
5.0
62.5
24
50.0
24
31.0
48
300.0
167.0
125.0
100.0
62.5
48
9.0
48
12.0
15.0
24.0
5.0
470
48
470
48
220
48
150.0
83.3
1,000
220
220
220
100
48
9.0
48
12.0
15.0
24.0
62.5
48
50.0
48
31.0
NEW DIP DC/DC Converter
Families From MPD
For the alternate pin-out (see page 4) , add suffix “P2” to model number
(i.e. MA124S-05RU-P2)
Series
Power
1W
1W
1W
1W
2W
2W
2W
2W
3W
3W
3W
3W
4W
4W
4W
4W
5W
5W
5W
5W
6W
6W
6W
6W
Input Range
Isolation
Notes:
MA100X-xxRW
MA100X-xxRWI
MA100X-xxRU
MA100X-xxRUI
MA200X-xxRW
MA200X-xxRWI
MA200X-xxRU
MA200X-xxRUI
MA300X-xxRW
MA300X-xxRWI
MA300X-xxRU
MA300X-xxRUI
MA400X-xxRW
MA400X-xxRWI
MA400X-xxRU
MA400X-xxRUI
MA500X-xxRW
MA500X-xxRWI
MA500X-xxRU
MA500X-xxRUI
MA600X-xxRW
MA600X-xxRWI
MA600X-xxRU
MA600X-xxRUI
2:1
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.0 kVDC
1.5 kVDC
3.0 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.5 kVDC
1.5 kVDC
3.0 kVDC
1.5 kVDC
3.0 kVDC
1. Cross regulation is measured with the output being tested at 100% load while
the other output is varied from 25% to 100% load.
2. See the typical connection circuit on page three for typical external filtering components.
For help with a specific model or layout issue, contact the factory.
3. Isolation voltage is specified for Input to output. On units with the optional metal case,
the isolation voltage for Input - Case and Output - Case is 1,000 VDC.
4. Operation at no-load will not damage the unit, but they may not meet all specifications.
To meet all specifications, a minimum load of 33% should be maintained.
5. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
2:1
4:1
4:1
2:1
2:1
4:1
4:1
2:1
Model Number
2:1
4:1
4:1
2:1
2:1
4:1
4:1
2:1
2:1
4:1
4:1
2:1
2:1
4:1
4:1
Visit our website or contact the factory for more information.
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com
Typical Connection
The diagram above illustrates a typical connection of the MA100RU
The recommended values for components are:
series for applications that require meeting conducted EMC standards.
The units do not require external components to operate as specified.
For applications requiring very low output noise levels, the output
filtering capacitors (C3 is a low ESR electrolytic & C4 is a ceramic) will
often be sufficient. Care must be taken in choosing output capacitors
not to exceed the capacitive load specification for the unit. For dual
output units, output capacitors should be connected from each output
to common. All external components should be mounted as close to
the unit as possible.
Component
24 VIN
220 µF/100V
12 µH
48 VIN
220 µF/100V
12 µH
C1
LCM
C2
C3
C4
470 pF/4kV MLCC 470 pF/4kV MLCC
100 µF
4.7 - 10 µF
100 µF
4.7 - 10 µF
Typical Board Layout: With External Filter Components, Single Output
Typical Board Layout: With External Filter Components, Dual Output
Input noise and surge suppression modules are available for a number
of MPD DC/DC power supplies. Contact the factory for more information.
MicroPower Direct
• 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com
Mechanical Dimensions
Standard Units - Plastic Case
Standard Units - Metal Case
Pin Single Output
Pin
2
3
Dual Output
-VIN
-VIN
Common
-VOUT
+VOUT
Common
+VIN
2
3
9
-VIN
-VIN
No Pin
9
11 No Connection
11
14
16
22
23
14
16
22
23
+VOUT
-VOUT
+VIN
+VIN
+VIN
For the alternate pin-out, add suffix “P2” to model number
(i.e. MA124S-05RU-P2)
Alternate Pin-Out Units - Plastic Case
Alternate Pin-Out Units - Metal Case
Pin Connections
Pin Single Output
Pin
1
Dual Output
+VIN
1
+VIN
No Connection
-VOUT
OUT
3
3
Common
Common
+VOUT
-VIN
-VIN
+VOUT
10
11
12
13
14
15
10
11
12
13
14
15
22
23
24
+VOUT
-VIN
-VIN
+VOUT
-VOUT
Common
Common
-VOUT
22 No Connection
23 No Connection
Notes:
•
•
•
All dimensions are typical in inches (mm)
Tolerance x.xx = 0.02 ( 0.50)
Pin 1 is marked by a “dot” or indentation on the top of the unit
24
+VIN
+VIN
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号: