EN 60601 Approved
4:1 Input, 3W DIP,
DC/DC Converters
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• EN 60601 3RD Ed. Approved
Input
Parameter
• 3W Output Power
Conditions
24 VDC Input
Min.
8.0
Typ.
8.5
Max.
9.0
Units
• 4.0 kVrms Isolation
Input Start Voltage
48 VDC Input 13.0
110 VDC Input 26.0
24 VDC Input
15.0
30.0
17.0
34.0
8.5
VDC
• Reinforced Insulation
• 1 x MOPP & 2xMOOP per
EN 60601-1 3RD Edition &
ANSI/AAMI ES 60601-1
• 2 µA Leakage Current Max
• Wide 4:1 Input Range
• Compact 24 Pin DIP Case
• 110 VDC Input Models
• 1.0 MH MTBF
Under Voltage Shutdown
48 VDC Input
110 VDC Input
(Pi) Filter
16.0
32.0
VDC
mW
Input Filter
Short Circuit Input Power
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
2,000
Conditions
Min.
Typ.
Max.
1.0
Units
%
Dual Output , Balanced Loads
VIN = Min to Max
0.5
0.3
2.0
0.5
%
%
IOUT = 25% to 100%
5V Output Models
0.5
75
100
150
150
3.0
1.0
100
150
%
Ripple & Noise (20 MHz), See Note 2
mV P - P
All Other Models
Output Power Protection
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
Parameter
Isolation Voltage
Reinforced Insulation Working Voltage
Leakage Current
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
120
%
µSec
%
500
6.0
25% Load Step Change
0.02
0.05
%/ºC
Continuous (Autorecovery)
Conditions
Min.
60 Seconds 4,000
1,000 Vrms
Typ.
Max.
Units
Vrms
240 VAC, 60 Hz
500 VDC
2
µA
G⍀
pF
10
100 kHz, 1V
7
13
150
kHz
Standard
Criteria
Level
EMC
EMS
Complies With EN 55011 4TH Edition
Complies With EN 60601-1-2
Environmental
Parameter
Conditions
Min.
-40
Typ.
+25
Max.
+85
+100
+125
Units
Ambient
Case
Operating Temperature Range
°C
Storage Temperature Range
Cooling
Humidity
-50
Free Air Convection
RH, Non-condensing
95
%
Physical
Case Size
See Mechanical Diagram (Page 3)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Material
Weight
Reliability Specifications
Parameter
Non-Conductive Black Plastic (UL94-V0)
0.58 Oz (16.6g)
Conditions
Min.
Typ.
Max.
Units
MHours
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign
1.0
IEC/EN 60601-1 3RD Edition, 1XMOPP & 2xMOOP
Safety Standards
ANSI/AAMI ES 60601-1 1xMOPP & 2xMOOP Recognition (UL Certificate)
ANSI/AAMI ES 60601-1, CAN/CSA-C22.2 No.60601-1
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Absolute Maximum Ratings
Parameter
Conditions
24 VDC Input
Min.
Typ.
Max.
50.0
Units
VDC
ºC
Input Voltage Surge (1.0 Sec)
48 VDC Input
110 VDC Input
1.5 mm From Case For 10 Sec
100.0
180.0
260
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Capacitive Fuse Rating
Efficiency
Model
Voltage (VDC)
Current (mA)
Full-Load No-Load
Load
Slow-Blow
(mA)
Number
(%, Typ)
Voltage
(VDC)
Current
Current
(mA, Min)
(µF Max)
(mA, Max)
Nominal
24
Range
MA324SMRU-05RI4
MA324SMRU-12RI4
MA324DMRU-12RI4
MA324DMRU-15RI4
MA348SMRU-05RI4
MA348SMRU-12RI4
MA348DMRU-12RI4
MA348DMRU-15RI4
MA3110SMRU-05RI4
MA3110SMRU-12RI4
MA3110DMRW-12RI4
MA3110DMRW-15RI4
Notes:
9.0 - 40.0
160
151
151
151
80
20
20
20
29
10
10
10
10
5
5.0
12.0
12.0
15.0
5.0
600
250
125
100
600
250
125
100
600
250
125
100
90.0
37.5
18.8
15.0
90.0
37.5
18.8
15.0
90.0
37.5
18.8
15.0
78
83
83
83
78
83
83
83
78
83
83
83
1,000
470
1,100
1,100
1,100
1,100
500
24
9.0 - 40.0
24
9.0 - 40.0
220
24
9.0 - 40.0
220
48
18.0 - 80.0
18.0 - 80.0
18.0 - 80.0
18.0 - 80.0
36.0 - 160.0
36.0 - 160.0
36.0 - 160.0
36.0 - 160.0
1,000
470
48
75
12.0
12.0
15.0
5.0
500
48
75
220
500
48
75
220
500
110
110
110
110
35
1,000
470
250
33
5
12.0
12.0
15.0
250
33
5
220
250
33
5
220
250
1. The specified maximum capacitive load is for each output.
5. The converter should be connected to a low ac-impedance source. An input source with a highly
inductive impedance may affect the stability of the converter. In applications where the converter
output loading is high and input power is supplied over long lines, it may be necessary to use a
capacitor on the input to insure start-up. The size of the recommended capacitor is given below.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the
table above for the correct rating.
2. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be
placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common
for dual output units.
3. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
4. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this, connect
the load across the positive (+VOUT) and negative (-VOUT) outputs and float the output common.
Typical Connection/ Single Output
Typical Connection/ Dual Output
These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors, as shown in the typical
connection diagram above, will enhance stability and reduce output ripple. This simple connection includes a low ESR (<1ม at 100 kHz) capacitor connected across the input
(C1). It is recommended that a 4.7 µF be used for 24V input models, a 2.2 µF for 48V models and 1.0 µF for 100V input units. To improve the output ripple performance, a
3.3 µF is connected across the output. For dual output units, a 3.3 µF capacitor should be connected from each output to common.
Page 2
We Power Your Success - For Less
www.micropowerdirect.com
Temperature Derating, 20LFM (Ambient Air)
Temperature Derating, 400 LFM
Mechanical Dimensions
Pin Connections
Pin Single
Dual
1
+VIN
+VIN
11
12
13
15
23
24
No Pin Common
-VOUT
+VOUT
No Pin
-VIN
No Pin
-VOUT
+VOUT
-VIN
-VIN
-VIN
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
Medical Approved Power Products
Thousands of standard power products ranging from 0.5W to 500W are available from MPD in
a wide variety of packages and pin-outs. This includes many more DC/DC and AC/DC product
families with EN 60601 medical approval. Go to micropowerdirect.com for full information.
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
©2020 ICPDF网 联系我们和版权申明