MA312MS05HI [MPD]

MA300MHI SERIES;
MA312MS05HI
型号: MA312MS05HI
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

MA300MHI SERIES

文件: 总2页 (文件大小:282K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series  
MA300MHI  
High Isolation, 3W  
Medical Approved  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Key Features:  
3W Output Power  
3 kVAC rms Isolation  
Reinforced Insulation  
2 µA Leakage Current Max  
Fifteen Models  
Conditions  
Min.  
4.5  
Typ.  
5.0  
12.0  
24.0  
Max.  
5.5  
13.2  
26.4  
Units  
5 VDC Input  
Input Voltage Range  
12 VDC Input 10.8  
24 VDC Input 21.6  
(Pi) Filter (Complies with EN55022 Class A)  
VDC  
Input Filter  
Reverse Polarity Input Current  
Leakage Current  
0.5  
2
A
µA  
240 VAC, 60 Hz  
Compact DIP Case  
Single & Dual Outputs  
Meets EN55022  
Short Circuit Input Power  
2,500  
mW  
Output  
Parameter  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Conditions  
Min.  
Typ.  
Max.  
4.0  
4.0  
0.5  
1.0  
Units  
%
%
%
%
50% Load, Nominal VIN  
Dual Output , Balanced Loads  
VIN = Min to Max  
1.0 MH MTBF  
2.0  
0.3  
0.5  
30  
EN 60950 Approved  
EN 60601 Approved  
Load Regulation  
IOUT = 10% to 100%  
See Note 1  
Ripple & Noise (20 MHz)  
Temperature Coefficient  
Output Short Circuit  
General  
50  
0.02  
mV P - P  
%/ºC  
0.01  
Continuous (Autorecovery)  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
VAC rms  
VPk  
VAC  
G⍀  
Isolation Voltage, Rated  
Isolation Test Voltage  
Reinforced Insulation Working Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
60 Seconds 3,000  
Flash Tested For 1 Sec 4,500  
300  
500 VDC  
100 kHz, 1V  
10  
20  
60  
pF  
kHz  
25  
Conditions  
Min.  
-40  
Typ.  
Max.  
+75  
+95  
Units  
ºC  
ºC  
Ambient  
Case  
-50  
+125  
ºC  
Free Air Convection  
RH, Non-condensing  
Humidity  
95  
%
Physical  
Case Size  
Case Material  
Weight  
1.25 x 0.80 x 0.41 Inches (31.8 x 20.3 x 10.5 mm)  
Non-Conductive Black Plastic (UL94-V0)  
0.30 Oz (12.4g)  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Reliability Specifications  
Parameter  
MTBF  
Safety Approvals  
Absolute Maximum Ratings  
Parameter  
Conditions  
MIL HDBK 217F, 25ºC, Gnd Benign  
Min.  
1.0  
Typ.  
Max.  
Units  
MHours  
UL 60601, UL 60950, EN 60601, EN 60950  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Conditions  
Min.  
Typ.  
Max.  
7.5  
15.0  
30.0  
260  
Units  
5 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
12 VDC Input -0.7  
24 VDC Input -0.7  
1.5 mm From Case For 10 Sec  
All Models  
VDC  
Lead Temperature  
Internal Power Dissipation  
ºC  
mW  
3,000  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Capacitive  
Load  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Number  
Current (mA)  
Full-Load No-Load  
Voltage Current  
Current  
(µF, Max)  
(VDC) (mA, Max) (mA, Min)  
Nominal  
5.0  
5.0  
5.0  
5.0  
5.0  
12  
Range  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
MA305MS-05HI  
MA305MS-12HI  
MA305MS-15HI  
MA305MD-12HI  
MA305MD-15HI  
MA312MS-05HI  
MA312MS-12HI  
MA312MS-15HI  
MA312MD-12HI  
MA312MD-15HI  
MA324MS-05HI  
MA324MS-12HI  
MA324MS-15HI  
MA324MD-12HI  
MA324MD-15HI  
1,000  
960  
960  
1,000  
1,000  
420  
400  
400  
420  
420  
210  
195  
195  
210  
210  
130  
130  
130  
130  
130  
60  
60  
60  
60  
60  
5.0  
12.0  
15.0  
12.0  
15.0  
5.0  
12.0  
15.0  
12.0  
15.0  
5.0  
600  
250  
200  
125  
100  
600  
250  
200  
125  
100  
600  
250  
200  
125  
100  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
470  
470  
470  
220  
220  
470  
470  
470  
220  
220  
470  
470  
470  
220  
220  
60  
62  
62  
60  
60  
60  
62  
62  
60  
60  
60  
64  
64  
60  
60  
2,000  
2,000  
2,000  
2,000  
2,000  
1,000  
1,000  
1,000  
1,000  
1,000  
500  
12  
12  
12  
12  
24  
24  
24  
24  
40  
40  
40  
40  
12.0  
15.0  
12.0  
15.0  
500  
500  
500  
500  
24  
40  
Notes:  
Derating Curve  
1. When measuring output ripple, it is recommended that an external ±.33 µF ceramic  
capacitor be placed from the +VOUT pin to the -VOUT pin for single output units and from  
each output to common for dual output units. For noise sensitive applications, the use  
of 0.5 µF capacitors will reduce the output ripple.  
2. Dual output units may be connected to provide a 24 VDC or 3± VDC output. To do this,  
connect the load across the positive (+VOUT) and negative (-VOUT) outputs and float the  
output common.  
3. The converter should be connected to a low ac-impedance source. An input source with  
a highly inductive impedance may affect the stability of the converter. In applications  
where the converter output loading is high and input power is supplied over long lines,  
it may be necessary to use a capacitor on the input to insure start-up.  
In this case, it is recommended that a low ESR (ESR <0.±at 0±± kHz) capacitor be  
mounted close to the converter. For 5V input units a 4.7 µF is recommended, for 02V  
and 24V units a 2.2 µF.  
4. It is recommended that a fuse be used on the input of a power supply for protection.  
See the table above for the correct rating.  
Mechanical Dimensions  
Pin Connections  
Pin  
Single  
Dual  
1
+VIN  
+VIN  
2
+VIN  
+VIN  
10  
11  
12  
13  
15  
23  
24  
No Pin  
No Pin  
-VOUT  
+VOUT  
No Pin  
-VIN  
Common  
Common  
No Pin  
-VOUT  
+VOUT  
-VIN  
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = ±±.±0 (±±.25)  
-VIN  
-VIN  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MA312MS12HI

MA300MHI SERIES
MPD

MA312MS15HI

MA300MHI SERIES
MPD

MA312S-03ERW

2:1 Input, 3W DIP, Single & Dual Output DC/DC Con vert ers
MPD

MA312S-05ERW

2:1 Input, 3W DIP, Single & Dual Output DC/DC Con vert ers
MPD

MA312S-05R

Regulated, 3W DIP Single & Dual Output DC/DC Con vert ers
MPD

MA312S-12ERW

2:1 Input, 3W DIP, Single & Dual Output DC/DC Con vert ers
MPD

MA312S-12R

Regulated, 3W DIP Single & Dual Output DC/DC Con vert ers
MPD

MA312S-15ERW

2:1 Input, 3W DIP, Single & Dual Output DC/DC Con vert ers
MPD

MA312S-15R

Regulated, 3W DIP Single & Dual Output DC/DC Con vert ers
MPD

MA312S-24ERW

2:1 Input, 3W DIP, Single & Dual Output DC/DC Con vert ers
MPD

MA312S03RW

MA300RW SERIES
MPD

MA312S03RWI

MA300RWI SERIES
MPD