MA348S-15ERW [MPD]

2:1 Input, 3W DIP, Single & Dual Output DC/DC Con vert ers;
MA348S-15ERW
型号: MA348S-15ERW
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

2:1 Input, 3W DIP, Single & Dual Output DC/DC Con vert ers

文件: 总4页 (文件大小:850K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MA300ERWSeries  
2:1 Input, 3W DIP,  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Key Features:  
3W Output Power  
2:1 Input Voltage Range  
1,500 VDC Isolation  
30 Standard Models  
Efficiency to 86%  
Parameter  
Conditions  
Min.  
4.5  
9.0  
Typ.  
5.0  
12.0  
24.0  
48.0  
4.0  
8.0  
16.0  
33.0  
Max.  
9.0  
18.0  
36.0  
75.0  
4.5  
9.0  
18.0  
36.0  
Units  
5 VDC Input  
12 VDC Input  
24 VDC Input 18.0  
48 VDC Input 36.0  
Input Voltage Range  
Input Start Voltage  
VDC  
5 VDC Input  
3.5  
4.5  
12 VDC Input  
Compact DIP Case  
-40°C to +85°C Operation  
Industry Standard Pin-Out  
Low Cost  
VDC  
24 VDC Input 11.0  
48 VDC Input 24.0  
(Pi) Filter  
Input Filter  
Output  
Parameter  
Conditions  
Min.  
Typ.  
1.0  
1.5  
0.5  
0.2  
0.2  
15  
Max.  
3.0  
5.0  
1.0  
0.5  
0.5  
30  
Units  
IOUT = 5% to 100%  
IOUT = 0%  
Dual Outputs, Balanced Loads  
VIN = Min to Max  
Output Voltage Accuracy  
%
Output Voltage Balance  
Line Regulation  
Load Regulation  
Ripple & Noise (20 MHz)  
Noise (20 MHz)  
%
%
%
3.0 kV Isolation  
Models  
IOUT = 5% to 100%  
Available  
See Note 1  
mV P - P  
45  
75  
Transient Recovery Time, See Note 2  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
General  
0.5  
2.0  
0.02  
2.0  
5.0  
0.03  
mSec  
%
%/°C  
25% Load Step Change  
Continuous (Autorecovery)  
Parameter  
Conditions  
Min.  
60 Seconds 1,500  
500 VDC 1,000  
Typ.  
Max.  
Units  
VDC  
M  
pF  
kHz  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
100 kHz/0.1V  
120  
200  
Conditions  
Min.  
-40  
-55  
Typ.  
+25  
Max.  
+85  
+125  
Units  
°C  
°C  
Ambient  
Free Air Convection  
Humidity  
RH, Non-condensing  
95  
%
Physical  
Case Size  
Case Material  
Weight  
See Mechanical Diagram (Page 4)  
Aluminum Alloy  
MicroPower Direct  
292 Page Street  
Suite D  
0.49 Oz (14g)  
Stoughton, MA 02072  
USA  
Reliability Specifications  
Parameter  
MTBF  
Absolute Maximum Ratings  
Parameter  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Min.  
1.0  
Typ.  
Typ.  
Max.  
Units  
MHours  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Conditions  
Min.  
Max.  
12.0  
25.0  
50.0  
100.0  
300  
Units  
VDC  
°C  
5 VDC Input -0.7  
12 VDC Input -0.7  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
Lead Temperature  
1.5 mm From Case for 10 Sec  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Reflected  
Ripple  
Fuse  
Rating  
Input  
Output  
Capacitive  
Model  
Number  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Current (mA)  
Full-Load No-Load  
Load  
F, Max)  
Voltage Current  
Current  
(mA, Min)  
Current  
(mA Typ)  
Slow-Blow  
(mA)  
(VDC)  
(mA, Max)  
Nominal  
Range  
MA305S-05ERW  
MA305S-12ERW  
MA305S-15ERW  
MA305D-05ERW  
MA305D-12ERW  
MA305D-15ERW  
MA312S-03ERW  
MA312S-05ERW  
MA312S-12ERW  
MA312S-15ERW  
MA312S-24ERW  
MA312D-05ERW  
MA312D-09ERW  
MA312D-12ERW  
MA312D-15ERW  
MA324S-03ERW  
MA324S-05ERW  
MA324S-12ERW  
MA324S-15ERW  
MA324S-24ERW  
MA324D-05ERW  
MA324D-12ERW  
MA324D-15ERW  
MA348S-03ERW  
MA348S-05ERW  
MA348S-12ERW  
MA348S-15ERW  
MA348D-05ERW  
MA348D-12ERW  
MA348D-15ERW  
5
5
5
5
5
5
4.5 - 9.0  
4.5 - 9.0  
4.5 - 9.0  
4.5 - 9.0  
4.5 - 9.0  
811  
780  
780  
790  
770  
770  
338  
309  
302  
305  
302  
309  
298  
298  
295  
160  
155  
146  
146  
147  
153  
149  
149  
82  
40  
40  
40  
40  
40  
40  
30  
30  
30  
30  
30  
30  
30  
30  
30  
15  
15  
15  
15  
15  
15  
15  
15  
5
5.0  
12.0  
15.0  
5.0  
12.0  
15.0  
3.3  
600  
250  
200  
300  
125  
100  
909  
600  
250  
200  
125  
300  
166  
125  
100  
909  
600  
250  
200  
125  
300  
125  
100  
909  
600  
250  
200  
300  
125  
100  
30  
12  
10  
15  
6
74  
77  
77  
76  
78  
78  
74  
81  
83  
82  
83  
81  
84  
84  
85  
78  
81  
86  
86  
85  
82  
84  
84  
76  
82  
86  
86  
82  
84  
85  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
30.0  
4,700  
2,700  
2,200  
2,200  
1,800  
1,000  
4,700  
4,700  
2,700  
2,200  
1,800  
2,200  
2,000  
1,800  
1,000  
4,700  
4,700  
2,700  
2,200  
1,800  
2,200  
1,800  
1,000  
4,700  
4,700  
2,700  
2,200  
2,200  
1,800  
1,000  
1,600  
1,600  
1,600  
1,600  
1,600  
1,600  
750  
750  
750  
750  
750  
750  
750  
750  
750  
300  
300  
300  
300  
300  
300  
300  
300  
150  
150  
150  
150  
4.5 - 9.0  
5
12  
12  
12  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
48  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
46  
30  
12  
10  
6
15  
8
6
5.0  
12.0  
15.0  
24.0  
5.0  
9.0  
12.0  
15.0  
3.3  
5
46  
30  
12  
10  
6
15  
6
5
46  
30  
12  
10  
15  
6
5.0  
12.0  
15.0  
24.0  
5.0  
12.0  
15.0  
3.3  
77  
73  
73  
77  
75  
74  
5
5
5
5
5
5
5.0  
12.0  
15.0  
5.0  
12.0  
15.0  
150  
150  
150  
5
Notes:  
1. When measuring output ripple & noise, it is recommended that an  
external capacitor (1 µF to 10 µF) be placed from the +VOUT to the -VOUT  
pins for single output units and from each output to common for dual  
output models..  
Efficiency vs Input Voltage: Typical 24 VDC Input  
2. Transient recovery is measured to within a 1% error band for a load  
step change of 25%.  
3. These units should not be operated with a load under 5% of full load.  
Operation at no-load will not damage the unit, but they may not meet  
all specifications.  
4. It is recommended that a fuse be used on the input of a power supply  
for protection.See the Model Selection table above for the correct rating.  
Derating Curve  
Efficiency vs Output Load: Typical 24 VDC Input  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
www.micropowerdirect.com  
EMC Specifications  
Notes:  
Parameter  
Standard  
See Note 1 EN 55022  
See Note 1 EN 55022  
1. All units are rated for EN 55022 (CE/RE) class A without external components.  
They will meet class B with the addition of the MDCFM-02A(W) (or a similar  
discrete filter circuit). Contact the factory for more information.  
2. To meet the requirements of EN 61000-4-4 ( 2 kV), external components  
are needed. This can be done discretely as shown in the typical connection  
diagram below.With the addition of the MDCFM-02A(W), the unit will meet  
EN 61000-4-4 ( 4 kV). Contact the factory for more information.  
3. To meet the requirements of EN 61000-4-5 ( 2 kV), external components are  
needed.This can be done discretely,or with the addition of the MDCFM-02A(W).  
Contact the factory for more information.  
Radiated Emissions  
Conducted Emissions  
ESD  
RS  
Class A  
Class A  
EN 61000-4-2 Criteria B; 4 kV Contact, 8 kV Air  
EN 61000-4-3  
Criteria A; 10V/m  
Criteria B; 2 kV  
EFT  
Surge  
CS  
See Note 2 EN 61000-4-4  
See Note 3 EN 61000-4-5  
EN 61000-4-6  
Criteria B; 2 kV  
Criteria A; 3 Vrms  
Criteria B; 0% - 70%  
Voltage Dips  
EN 61000-4-29  
Typical Connection  
5. Recommended values for components are:  
The diagram above illustrates a typical connection of the MA300xERWseries  
for applications that require meeting EMC standards. The units do not require  
externalcomponentstooperateasspecified.Somenotesonthisdiagram(starting  
with the input circuit) are:  
1. It is recommended that an external fuse be used.The recommended fuse is  
shown in the model chart on page 2.  
2. An external MOV is recommended on the input to protect the unit in the event  
of a surge. A recommended value is given in the table at right.  
3. An external TVS is recommended on the input to protect the unit in the event  
of a voltage spike. A recommended value is given in the table at right.  
4. Theoutputlteringcapacitor(C5)isahighfrequency,lowresistanceelectrolytic  
capacitor. Care must be taken in choosing this capacitor not to exceed the  
capacitive load specification for the unit.Voltage derating of capacitors should  
be 80% or above.  
6. Input noise and surge suppression modules are available for a  
number of MPD DC/DC power supplies. For pricing or full technical  
information, please contact the factory.  
7. In many applications simply adding input/output capacitors  
will enhance the input surge protection and reduce output  
ripple sufficiently. The input capacitor C1 and output capaci-  
tors C5 and C6 shown in the typical connection diagram above  
(& board layout drawing below), illustrate their connection.  
Component  
5 VIN  
---  
---  
12 VIN  
---  
---  
24 VIN  
S14K35  
56 µH  
48 VIN  
MOV  
LDM1  
TVS  
C1  
S14K60  
56 µH  
SMCJ90A  
SMCJ13A  
SMCJ28A  
SMCJ48A  
680 µF/16V 680 µF/25V 330 µF/50V 330 µF/100V  
4.7 µF/50V 4.7 µF/50V 4.7 µF/50V 4.7 µF/100V  
C2  
LDM2  
C3  
12 µH  
12 µH  
12 µH  
12 µH  
The recommended capacitor values are as follows:  
4.7 µF/50V 4.7 µF/50V 4.7 µF/50V 4.7 µF/100V  
CIN  
5V/12V Input:  
24V/48V Input 10µF - 47 µF  
100 µF  
C4  
C5  
1 nF/2 kV  
10 µF  
1 nF/2 kV  
10 µF  
1 nF/2 kV  
10 µF  
1 nF/2 kV  
10 µF  
10 µF  
COUT All Models  
10µF/100mA  
C6  
10 µF  
10 µF  
10 µF  
Typical Board Layout: With External Filter/Surge Components for Single Output Unit  
Typical Connection: With External Filter/Surge Components for Dual Output Unit  
MicroPower Direct  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  
www.micropowerdirect.com  
Mechanical Dimensions  
Pin Connections  
Pin Single Output  
Pin  
2
3
Dual Output  
-VIN  
2
-VIN  
-VIN  
3
-VIN  
9
No Pin  
No Connection  
+VOUT  
9
Common  
-VOUT  
+VOUT  
Common  
+VIN  
11  
14  
16  
22  
23  
11  
14  
16  
22  
23  
-VOUT  
+VIN  
+VIN  
+VIN  
Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.02 ( 0.50)  
Pin 1 is marked by a “dot” or indentation on the top of the unit  
Packing Tube Dimensions  
Notes:  
Tube length equals 20.866 (530), unit quantity equals 15 pcs.  
Tube length equals 8.661 (220), unit quantity equals 6 pcs.  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.02 ( 0.50)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MA348S-24ERU

Wide 4:1 Input, 3W Single Output DIP DC/DC Con vert ers
MPD

MA348S03RU

MA300RU SERIES
MPD

MA348S03RUI

MA300RUI SERIES
MPD

MA348S03RW

MA300RW SERIES
MPD

MA348S03RWI

MA300RWI SERIES
MPD

MA348S05RU

MA300RU SERIES
MPD

MA348S05RUI

MA300RUI SERIES
MPD

MA348S05RW

MA300RW SERIES
MPD

MA348S05RWI

MA300RWI SERIES
MPD

MA348S12RU

MA300RU SERIES
MPD

MA348S12RUI

MA300RUI SERIES
MPD

MA348S12RW

MA300RW SERIES
MPD