MA448S05RWI [MPD]
MA400RWI SERIES;型号: | MA448S05RWI |
厂家: | MICROPOWER DIRECT, LLC |
描述: | MA400RWI SERIES |
文件: | 总4页 (文件大小:1516K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MA400RWISeries
Wide 2:1 Input, 4W,
High Isolation, DIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 4W Output Power
• 2:1 Input Voltage Range
• 3,500 VDC Isolation
• 30 Standard Models
• High Efficiency
Parameter
Conditions
12 VDC Input
Min.
Typ.
12.0
24.0
48.0
35
Max.
18.0
36.0
72.0
Units
VDC
9.0
Input Voltage Range
24 VDC Input 18.0
48 VDC Input 36.0
Input Reflected Ripple Current
Input Filter
mA P - P
ꢀ (Pi) Filter
• Compact DIP Case
• -40°C to +85°C Operation
• Metal Case Available
• Low Cost
Output
Parameter
Conditions
Min.
Typ.
1.0
0.5
0.5
0.5
60
Max.
Units
%
Output Voltage Accuracy
Line Regulation
VIN = Min to Max
IOUT = 25% to 100%
See Note 1
%
Load Regulation
%
Load Regulation
%
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
General
See Note 2
mV P - P
%/°C
0.02
Alternate
Pin-Out
Available
Continuous (Autorecovery)
Parameter
Conditions
Min.
3 Seconds 3,500
500 VDC 1,000
Typ.
Max.
Units
VDC
M
Isolation Voltage, See Note 3
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
1.5 kV Isolation
Models
100 kHz/0.1V
60
pF
100
400
kHz
Available
Conditions
Min.
Typ.
Max.
+85
Units
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-40
+25
+100
+125
°C
-40
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Non-Conductive Black Plastic (UL94-V0)
0.44 Oz (12.5g)
Case Material, Plastic
Weight, Plastic Case
Case Material, Metal
Weight, Metal Case
Reliability Specifications
Parameter
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Nickel-Coated Copper With Non-Conductive Base (UL94-V0)
0.53 Oz (15g)
Conditions
Min.
Typ.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
1.0
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Absolute Maximum Ratings
Parameter
Conditions
Min.
Max.
24.0
40.0
80.0
260
Units
VDC
°C
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Fuse
Rating
Reflected
Ripple
Capacitive
Model
Number
Efficiency
(%, Typ)
Voltage (VDC)
Current (mA)
Full-Load No-Load
Load
Voltage Current
Current
Current
(mA Typ)
Slow-Blow
(mA)
(µF, Max)
(VDC)
(mA, Max) (mA, Min)
Nominal
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
48
48
Range
MA412S-05RWI-xx
MA412S-09RWI-xx
MA412S-12RWI-xx
MA412S-15RWI-xx
MA412S-24RWI-xx
MA412D-05RWI-xx
MA412D-09RWI-xx
MA412D-12RWI-xx
MA412D-15RWI-xx
MA412D-24RWI-xx
MA424S-05RWI-xx
MA424S-09RWI-xx
MA424S-12RWI-xx
MA424S-15RWI-xx
MA424S-24RWI-xx
MA424D-05RWI-xx
MA424D-09RWI-xx
MA424D-12RWI-xx
MA424D-15RWI-xx
MA424D-24RWI-xx
MA448S-05RWI-xx
MA448S-09RWI-xx
MA448S-12RWI-xx
MA448S-15RWI-xx
MA448S-24RWI-xx
MA448D-05RWI-xx
MA448D-09RWI-xx
MA448D-12RWI-xx
MA448D-15RWI-xx
MA448D-24RWI-xx
Notes:
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
463
427
427
433
439
433
433
427
427
433
216
214
211
208
216
225
225
219
216
219
108
108
107
107
111
114
108
108
107
110
20
20
20
20
20
20
20
20
20
20
12
12
12
12
12
12
12
12
12
12
8
5.0
9.0
800.0
444.0
333.0
267.0
167.0
400.0
222.0
167.0
133.0
83.0
200.0
111.0
83.3
66.8
42.0
100.0
56.0
42.0
33.0
21.0
200.0
111.0
83.3
66.8
42.0
100.0
56.0
42.0
33.0
21.0
200.0
111.0
83.3
66.8
42.0
100.0
56.0
42.0
33.0
21.0
72
78
78
77
76
77
77
78
78
77
77
78
79
80
77
77
77
78
79
76
77
77
78
77
75
73
77
77
78
76
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
2,200
470
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
12.0
15.0
24.0
5.0
470
470
220
1,000
220
220
220
100
2,200
470
9.0
12.0
15.0
24.0
5.0
800.0
444.0
333.0
267.0
167.0
400.0
222.0
167.0
133.0
83.0
9.0
500
12.0
15.0
24.0
5.0
470
500
470
500
220
500
1,000
220
220
220
100
2,200
470
500
9.0
500
12.0
15.0
24.0
5.0
500
500
500
800.0
444.0
333.0
267.0
167.0
400.0
222.0
167.0
133.0
83.0
250
8
9.0
250
8
12.0
15.0
24.0
5.0
470
250
8
470
250
8
220
250
8
1,000
220
220
220
100
250
8
9.0
250
8
12.0
15.0
24.0
250
8
250
8
250
1. Cross regulation is measured with the output being tested at 100% load while the other output
is varied from 25% to 100% load.
2. See the typical connection circuit on page three for typical external filtering components. For help with a
specific model or layout issue, contact the factory.
3. Isolation voltage is specified for Input to output. On units with the optional metal case, the isolation voltage
for Input - Case and Output - Case is 1,000 VDC.
For the alternate pin-out (see page 4) , add suffix “P2” to model number
(i.e. MA424S-05RWI-P2)
4. Operation at no-load will not damage the unit,but they may not meet all specifications.To meet all specifica-
tions, a minimum load of 25% should be maintained.
5. It is recommended that a fuse be used on the input of a power supply for protection.See the Model Selection
table above for the correct rating.
Model Number
Derating Curve
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com
Typical Connection
The diagram above illustrates a typical connection of the MA400RWI
The recommended values for components are:
series for applications that require meeting conducted EMC standards.
The units do not require external components to operate as specified.
For applications requiring very low output noise levels, the output
filtering capacitors (C3 is a low ESR electrolytic & C4 is a ceramic) will
often be sufficient. Care must be taken in choosing output capacitors
not to exceed the capacitive load specification for the unit. For dual
output units, output capacitors should be connected from each output
to common. All external components should be mounted as close to
the unit as possible.
Component
12 VIN
220 µF/50V
12 µH
---
100 µF
24 VIN
220 µF/100V
12 µH
48 VIN
220 µF/100V
12 µH
C1
LCM
C2
C3
C4
470 pF/4kV MLCC 470 pF/4kV MLCC
100 µF
4.7 - 10 µF
100 µF
4.7 - 10 µF
4.7 - 10 µF
Typical Board Layout: With External Filter Components, Single Output
Typical Board Layout: With External Filter Components, Dual Output
Input noise and surge suppression modules are available for a number
of MPD DC/DC power supplies. Contact the factory for more information.
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com
Mechanical Dimensions
Standard Units - Plastic Case
Standard Units - Metal Case
Pin Single Output
Pin
2
3
Dual Output
-VIN
-VIN
Common
-VOUT
+VOUT
Common
+VIN
2
3
9
-VIN
-VIN
No Pin
9
11 No Connection
11
14
16
22
23
14
16
22
23
+VOUT
-VOUT
+VIN
+VIN
+VIN
For the alternate pin-out, add suffix “P2” to model number
(i.e. MA424S-05RWI-P2)
Alternate Pin-Out Units - Plastic Case
Alternate Pin-Out Units - Metal Case
Pin Connections
Pin Single Output
Pin
1
Dual Output
+VIN
1
+VIN
No Connection
-VOUT
OUT
3
3
Common
Common
+VOUT
-VIN
-VIN
+VOUT
10
11
12
13
14
15
10
11
12
13
14
15
22
23
24
+VOUT
-VIN
-VIN
+VOUT
-VOUT
Common
Common
-VOUT
22 No Connection
23 No Connection
Notes:
•
•
•
All dimensions are typical in inches (mm)
Tolerance x.xx = 0.02 ( 0.50)
Pin 1 is marked by a “dot” or indentation on the top of the unit
24
+VIN
+VIN
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号: