MA624D15RU [MPD]

MA600RU SERIES;
MA624D15RU
型号: MA624D15RU
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

MA600RU SERIES

文件: 总2页 (文件大小:490K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MA600RU Series  
Wide 4:1 Input, 6W,  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Key Features:  
6W Output Power  
Input  
Parameter  
Conditions  
24 VDC Input  
Min.  
7.0  
Typ.  
8.0  
16.0  
Max.  
9.0  
18.0  
8.5  
Units  
Input Start Voltage  
VDC  
4:1 Input Voltage Range  
1,500 VDC Isolation  
16 Standard Models  
Single & Dual Outputs  
Compact DIP Case  
-40°C to +85°C Operation  
Industry Standard Pin-Out  
48 VDC Input 14.0  
24 VDC Input  
48 VDC Input  
(Pi) Filter  
Under Voltage Shutdown  
VDC  
17.5  
Input Filter  
Output  
Parameter  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Load Regulation  
Conditions  
Min.  
Typ.  
1.0  
1.0  
0.1  
0.6  
Max.  
2.0  
2.0  
0.5  
1.2  
70  
100  
600  
Units  
%
%
%
%
Dual Output, Balanced Loads  
VIN = Min to Max  
IOUT = 0% to 100%  
See Note 1  
Over Line, Load & Temp.  
Ripple & Noise (20 MHz)  
mV P - P  
Transient Recovery Time, See Note 2  
Transient Response Deviation  
Temperature Coefficient  
Output Overload Protection  
Output Short Circuit  
General  
300  
3.0  
0.01  
145  
µSec  
%
%/°C  
%
25% Load Step Change  
0.02  
3.0 kV Isolation  
Models  
Foldback  
Continuous (Autorecovery)  
110  
Available  
Parameter  
Conditions  
Min.  
60 Seconds 1,500  
500 VDC 1,000  
Typ.  
Max.  
Units  
VDC  
M  
pF  
kHz  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
EMI Characteristics  
Parameter  
2:1 Input Range  
Models  
100 kHz/1.0V  
1,000  
330  
Available  
Standard  
Level  
Radiated Emissions  
Conducted Emissions  
ESD  
EN 55022  
EN 55022  
Class A  
Class A  
EN 61000-4-2 Criteria A; 8 kV Air 6 kV Contact  
RS  
EFT  
Surge  
CS  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
Criteria A; 10V/m  
Criteria A; 2 kV  
Criteria A; 1 kV  
Criteria A; 10V/m  
See Note 3  
See Note 3  
Environmental  
Parameter  
Conditions  
Min.  
-40  
Typ.  
+25  
Max.  
+85  
+100  
+125  
Units  
°C  
°C  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Ambient  
Case  
-50  
°C  
Free Air Convection  
RH, Non-condensing  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Humidity  
95  
%
Physical  
Case Size  
Case Material  
Weight  
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)  
Non-Conductive Black Plastic (UL94-V0)  
0.45 Oz (12.8g)  
Reliability Specifications  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Parameter  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Min.  
800  
Typ.  
Typ.  
Max.  
Units  
kHours  
MTBF  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Max.  
50.0  
100.0  
260  
Units  
VDC  
°C  
24 VDC Input -0.7  
48 VDC Input -0.7  
1.5 mm From Case for 10 Sec  
Input Voltage Surge (1 Sec)  
Lead Temperature  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Fuse  
Rating  
Reflected  
Ripple  
Capacitive  
Model  
Number  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Current (mA)  
Full-Load No-Load  
Load  
Voltage Current  
Current  
Current  
(mA Typ)  
Slow-Blow  
(mA)  
F, Max)  
(VDC)  
(mA, Max) (mA, Min)  
Nominal  
24  
Range  
MA624S-05RU  
MA624S-05RU  
MA624S-12RU  
MA624S-15RU  
MA624S-24RU  
MA624D-05RU  
MA624D-12RU  
MA624D-15RU  
MA648S-03RU  
MA648S-05RU  
MA648S-12RU  
MA648S-15RU  
MA648S-24RU  
MA648D-05RU  
MA648D-12RU  
MA648D-15RU  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
214  
313  
298  
298  
298  
260  
298  
298  
107  
156  
149  
149  
149  
130  
149  
149  
20  
20  
20  
20  
20  
20  
20  
20  
10  
10  
10  
10  
10  
10  
10  
10  
3.3  
5.0  
1,200.0  
1,200.0  
500.0  
400.0  
250.0  
500.0  
250.0  
200.0  
1,200.0  
1,200.0  
500.0  
400.0  
250.0  
500.0  
250.0  
200.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
77  
80  
84  
84  
84  
80  
84  
84  
77  
80  
84  
84  
84  
80  
84  
84  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
15.0  
15.0  
15.0  
15.0  
15.0  
15.0  
15.0  
15.0  
470  
470  
100  
100  
47  
1,500  
1,500  
1,500  
1,500  
1,500  
1,500  
1,500  
1,500  
800  
24  
24  
12.0  
15.0  
24.0  
5.0  
24  
24  
24  
100  
100  
100  
470  
470  
100  
100  
47  
24  
12.0  
15.0  
3.3  
24  
48  
48  
5.0  
800  
48  
12.0  
15.0  
24.0  
5.0  
800  
48  
800  
48  
800  
48  
100  
100  
100  
800  
48  
12.0  
15.0  
800  
48  
800  
Notes:  
Derating Curve  
0. When measuring output ripple, it is recommended that an external 3.3 µF ceramic capacitor be  
placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common  
for dual output units.  
2. Transient recovery is measured to within a 0% error band for a load step change of 75% to 0±±%.  
3. Operation at no-load will not damage these units.  
4. An external 22± µF/0±±V capacitor connected across the input pins is required to meet  
EN60±±±-4-4 and EN60±±±-4-5.  
5. Dual output units may be connected to provide a 0±, 24 or 3± VDC output. To do this, connect the  
load across the positive (+VOUT) and negative (-VOUT) outputs and float the output common.  
6. The converter should be connected to a low ac-impedance source. An input source with a highly  
inductive impedance may affect the stability of the converter. In applications where the converter  
output loading is high and input power is supplied over long lines, it may be necessary to use  
a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR  
<0.±at 0±± kHz) capacitor be mounted close to the converter. For 24V input units a 4.7 µF is  
recommended; and for 48V units a 2.2 µF.  
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table  
above for the correct rating.  
Mechanical Dimensions  
For 3 kV Isolation, See MA600x-xxRUI Series Datasheet  
For 2:1 Inputs, See MA600x-xxRW Series Datasheet  
Pin Connections  
Pin  
Single  
Dual  
2, 3  
9
-VIN  
-VIN  
No Pin Common  
11  
NC  
-VOUT  
+VOUT  
14  
+VOUT  
-VOUT  
+VIN  
16  
Common  
+VIN  
22, 23  
NC: No Connection  
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.x = ±±.±2 (±±.5±)  
Tolerance x.xx = ±±.±0 (±±.25)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MA624D15RUI

MA600RUI SERIES
MPD

MA624D15RW

MA600RW SERIES
MPD

MA624D15RWI

MA600RWI SERIES
MPD

MA624DMRW-12RI5

EN 60601 Approved 2:1 Input, DIP, 6W DC/DC Con vert ers
MPD

MA624DMRW-15RI5

EN 60601 Approved 2:1 Input, DIP, 6W DC/DC Con vert ers
MPD

MA624MD12HI

MA600MHI SERIES
MPD

MA624MD15HI

MA600MHI SERIES
MPD

MA624MS05HI

MA600MHI SERIES
MPD

MA624MS12HI

MA600MHI SERIES
MPD

MA624S-03ERU

4:1 Input, 6W DIP, Single & Dual Output DC/DC Con vert ers
MPD

MA624S-05ERU

4:1 Input, 6W DIP, Single & Dual Output DC/DC Con vert ers
MPD

MA624S-05ERUI

Wide 4:1 Input, 6W, High Isolation, DIP DC/DC Con vert ers
MPD