MA648D-15ERU [MPD]

4:1 Input, 6W DIP, Single & Dual Output DC/DC Con vert ers;
MA648D-15ERU
型号: MA648D-15ERU
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

4:1 Input, 6W DIP, Single & Dual Output DC/DC Con vert ers

文件: 总4页 (文件大小:901K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MA600ERUSeries  
4:1 Input, 6W DIP,  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Key Features:  
Input  
Parameter  
Conditions  
24 VDC Input  
Min.  
9.0  
Typ.  
24.0  
48.0  
Max.  
36.0  
75.0  
9.0  
Units  
6W Output Power  
4:1 Input Voltage Range  
1,500 VDC Isolation  
17 Standard Models  
Efficiency to 88%  
Input Voltage Range  
VDC  
48 VDC Input 18.0  
24 VDC Input  
48 VDC Input  
(Pi) Filter  
Input Start Voltage  
VDC  
18.0  
Input Filter  
Output  
Parameter  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation, See Note 1  
Load Regulation  
Cross Regulation  
Ripple (20 MHz)  
Conditions  
Min.  
Typ.  
1.0  
0.5  
0.2  
0.5  
Max.  
2.0  
1.5  
0.5  
1.0  
5.0  
25  
Units  
%
%
%
%
Compact DIP Case  
-40°C to +85°C Operation  
Industry Standard Pin-Out  
Low Cost  
IOUT = 5% to 100%  
Dual Outputs, Balanced Loads  
VIN = Min to Max  
IOUT = 5% to 100%  
See Note 2  
See Note 3  
3.3, 5 VDC Output  
All Other Outputs  
%
mV P - P  
10  
30  
50  
300  
3.0  
80  
Noise (20 MHz), See Note 3  
mV P - P  
100  
500  
5.0  
0.03  
140  
Transient Recovery Time, See Note 4  
Transient Response Deviation  
Temperature Coefficient  
Output Over Voltage Protection  
Output Short Circuit, See Note 5  
General  
µSec  
%
%/°C  
%
25% Load Step Change  
3.0 kV Isolation  
Models  
110  
Continuous (Autorecovery)  
Available  
Parameter  
Conditions  
Min.  
60 Seconds 1,500  
500 VDC 1,000  
Typ.  
Max.  
Units  
VDC  
M  
pF  
kHz  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
EMI Characteristics  
Parameter  
Radiated Emissions  
Conducted Emissions  
ESD  
RS  
EFT  
Surge  
CS  
100 kHz/0.1V  
1,000  
300  
Standard  
See Note 6  
See Note 6  
Level  
Class A  
Class A  
EN 55022  
EN 55022  
EN 61000-4-2  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-29  
Criteria B; 4 kV Contact  
Criteria A; 10V/m  
Criteria B; 2 kV  
Criteria B; 2 kV  
Criteria A; 3 Vrms  
Criteria B; 0% - 70%  
See Note 7  
See Note 8  
Voltage Dips  
Environmental  
Parameter  
Conditions  
Min.  
-40  
Typ.  
+25  
Max.  
+85  
+105  
+125  
Units  
°C  
°C  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Ambient  
Case  
-55  
°C  
MicroPower Direct  
292 Page Street  
Suite D  
Free Air Convection  
Humidity  
Physical  
RH, Non-condensing  
95  
%
Case Size  
Case Material  
See Mechanical Diagram (Page 4)  
Aluminum Alloy  
Stoughton, MA 02072  
USA  
Weight  
0.49 Oz (14g)  
Reliability Specifications  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Parameter  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Min.  
1.0  
Typ.  
Typ.  
Max.  
Units  
MHours  
MTBF  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Max.  
50.0  
100.0  
300  
Units  
VDC  
°C  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
Lead Temperature  
1.5 mm From Case for 10 Sec  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Fuse  
Rating  
Reflected  
Ripple  
Capacitive  
Model  
Number  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Current (mA)  
Full-Load No-Load  
Load  
Voltage Current  
Current  
(mA, Min)  
Current  
(mA Typ)  
Slow-Blow  
(mA)  
F, Max)  
(VDC)  
(mA, Max)  
Nominal  
24  
Range  
MA624S-03ERU  
MA624S-05ERU  
MA624S-12ERU  
MA624S-15ERU  
MA624S-24ERU  
MA624D-05ERU  
MA624D-12ERU  
MA624D-15ERU  
MA624D-24ERU  
MA648S-03ERU  
MA648S-05ERU  
MA648S-12ERU  
MA648S-15ERU  
MA648S-24ERU  
MA648D-05ERU  
MA648D-12ERU  
MA648D-15ERU  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
316  
301  
287  
284  
287  
301  
287  
287  
287  
156  
148  
144  
142  
144  
150  
144  
144  
7
7
7
7
7
7
7
7
7
3
3
3
3
3
3
3
3
3.3  
5.0  
1,500  
1,200  
500  
75  
60  
25  
20  
12  
30  
12  
10  
6.25  
75  
60  
25  
20  
12  
30  
12  
10  
79  
83  
87  
88  
87  
83  
87  
87  
87  
80  
84  
87  
88  
87  
83  
87  
87  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
20.0  
1,800  
1,000  
100  
100  
47  
600  
600  
600  
600  
600  
600  
600  
600  
600  
300  
300  
300  
300  
300  
300  
300  
300  
24  
24  
12.0  
15.0  
24.0  
5.0  
24  
400  
24  
250  
24  
600  
470  
100  
100  
47  
24  
12.0  
15.0  
24.0  
3.3  
250  
24  
200  
24  
125  
48  
1,500  
1,200  
500  
1,800  
1,000  
100  
100  
47  
48  
5.0  
48  
12.0  
15.0  
24.0  
5.0  
48  
400  
48  
250  
48  
600  
470  
100  
100  
48  
12.0  
15.0  
250  
48  
200  
Notes:  
Derating Curve  
1. On dual output models, the line regulation for the -VOUT (pin 16) output is 1.0% max.  
2. Cross regulation is measured with the +VOUT (pin 14) set to 50% load and the -VOUT (pin 16)  
varied from 10% to 100% load.The load on dual output models should not be unbalanced more  
than 5%. If the load unbalance is greater than 5%, the unit may not meet all specifications.  
3. When measuring output ripple & noise, it is recommended that an external capacitor  
(1 µF to 10 µF) be placed from the +VOUT to the -VOUT pins for single output units and from each  
output to common for dual output models..  
4. Transient recovery is measured to within a 1% error band for a load step change of 25%.  
5. Short circuit protection is provided by a “hiccup mode” circuit.  
6. All units are rated for EN 55022 (CE/RE) class A without external components. They will meet  
class B with the addition of a discrete filter circuit as shown on page 3. Contact the factory for  
more information this circuit or one of our filter/surge suppression modules.  
7. To meet the requirements of EN 61000-4-4 ( 2 kV) external components are needed, as  
shown on page 3. Contact the factory for more information this circuit or one of our filter/  
surge suppression modules.  
8. To meet the requirements of EN 61000-4-5 ( 2 kV), external components are needed.This can  
be done discretely as shown on page 3. Contact the factory for more information this circuit  
or one of our filter/surge suppression modules.  
9. These units should not be operated with a load under 5% of full load. Operation at no-load will  
not damage the unit, but they may not meet all specifications.  
10. It is recommended that a fuse be used on the input of a power supply for protection. See the  
Model Selection table above for the correct rating.  
Efficiency vs Input Voltage: 48 VDC Input  
Efficiency vs Output Load: 48 VDC Input  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
www.micropowerdirect.com  
Typical Connection  
4. In many applications simply adding input/output capaci-  
The diagram above illustrates a typical connection of the MA600ERUIseries  
for applications that require meeting EMC standards. The units do not require  
external components to operate as specified. Some notes on this diagram  
(starting with the input circuit) are:  
1. It is recommended that an external fuse be used.The recommended fuse is  
shown in the model chart on page 2.  
2. An external MOV is recommended on the input to protect the unit in the event  
of a surge. A recommended value is given in the table at right.  
3. The output filtering capacitor (C3) is a low ESR electrolytic capacitor. Care  
must be taken in choosing this capacitor not to exceed the capacitive load  
specification for the unit. Voltage derating of capacitors should be 80% or  
above.  
5. Recommended values for components are:  
tors will enhance the input surge protection and reduce  
output ripple sufficiently. Typically, the value of the input  
capacitor should be 10 µF to 47 µF. The output capacitor  
would be 10 µF.  
5. Input noise and surge suppression modules are available for  
a number of MPD DC/DC power supplies. For a recommen-  
dation for the MA600xERU series, please contact the factory.  
Component  
MOV  
C1  
24 VIN  
S14K35  
330 µF/50V  
1.0 µF/50V  
4.7 µH  
1 nF/2 kV  
1 nF/2 kV  
10 µF  
48 VIN  
S14K60  
330 µF/100V  
1.0 µF/100V  
4.7 µH  
1 nF/2 kV  
1 nF/2 kV  
10 µF  
C2  
LDM1  
CY1  
CY2  
C3  
Typical Board Layout: Single Output With External Filter/Surge Components  
Typical Board Layout: Dual Output With External Filter/Surge Components  
MicroPower Direct  
292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
www.micropowerdirect.com  
Mechanical Dimensions  
Pin Connections  
Pin Single Output  
Pin  
2
3
Dual Output  
-VIN  
2
-VIN  
-VIN  
3
-VIN  
9
No Pin  
No Connection  
+VOUT  
9
Common  
-VOUT  
+VOUT  
Common  
+VIN  
11  
14  
16  
22  
23  
11  
14  
16  
22  
23  
-VOUT  
+VIN  
+VIN  
+VIN  
Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.02 ( 0.50)  
Pin 1 is marked by a “dot” or indentation on the top of the unit  
Packing Tube Dimensions  
Notes:  
Tube length equals 20.866 (530), unit quantity equals 15 pcs.  
Tube length equals 8.661 (220), unit quantity equals 6 pcs.  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.02 ( 0.50)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MA648D05RU

MA600RU SERIES
MPD

MA648D05RUI

MA600RUI SERIES
MPD

MA648D05RW

MA600RW SERIES
MPD

MA648D05RWI

MA600RWI SERIES
MPD

MA648D12RU

MA600RU SERIES
MPD

MA648D12RUI

MA600RUI SERIES
MPD

MA648D12RW

MA600RW SERIES
MPD

MA648D12RWI

MA600RWI SERIES
MPD

MA648D15RU

MA600RU SERIES
MPD

MA648D15RUI

MA600RUI SERIES
MPD

MA648D15RW

MA600RW SERIES
MPD

MA648D15RWI

MA600RWI SERIES
MPD