MA848S05RW [MPD]

MA800RW SERIES;
MA848S05RW
型号: MA848S05RW
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

MA800RW SERIES

文件: 总2页 (文件大小:243K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MA800RWSeries  
2:1 Input Range, 8W  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Conditions  
Min.  
9.0  
Typ.  
12.0  
24.0  
48.0  
Max.  
18.0  
36.0  
72.0  
Units  
VDC  
Key Features:  
12 VDC Input  
8W Output Power  
Input Voltage Range  
24 VDC Input 18.0  
48 VDC Input 36.0  
(Pi) Filter (Meets EN 55022 Class “A”)  
2:1 Input Voltage Range  
Compact DIP Case  
Input Filter  
Input Reflected Ripple Current  
Output  
Parameter  
Output Voltage Accuracy  
35.0  
mA P - P  
1,500 VDC I/O Isolation  
Meets EN 55022 “A”  
Single & Dual Outputs  
Wide Temperature Operation  
Industry Standard Pin-Out  
Conditions  
VIN = Min to Max  
Min.  
Typ.  
1.0  
Max.  
Units  
%
%
Line Regulation  
0.5  
0.5  
1.0  
5.0  
75  
Single Output  
Dual Output  
See Note 2  
See Note 3  
Load Regulation, See Note 1  
%
Cross Regulation, Dual Output  
Ripple & Noise (20 MHz)  
Output Power Protection  
Temperature Coefficient  
Output Short Circuit Protection  
General  
%
mV P - P  
% IOUT  
%/ºC  
150  
0.02  
Continuous (Autorecovery)  
Parameter  
Conditions  
Min.  
3 Seconds 1,500  
3 Seconds 1,000  
500 VDC 1,000  
100 kHz/1V  
Typ.  
Max.  
Units  
Isolation Voltage (Input/Output)  
Isolation Voltage (Case/Input, Output)  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
EMI Characteristics  
Parameter  
VDC  
M⍀  
pF  
kHz  
1,000  
330  
Standard  
Level  
Radiated Emissions  
Conducted Emissions, See Note 4  
ESD  
EN 55022  
EN 55022  
Class A  
Class A  
EN 61000-4-2  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-8  
Criteria B  
Criteria A  
Criteria B  
Criteria B  
Criteria A  
Criteria A  
RS  
EFT, See Note 4  
Surge, See Note 4  
CS  
PFMF  
Environmental  
Parameter  
Conditions  
Min.  
-40  
Typ.  
Max.  
+85  
+100  
+125  
Units  
ºC  
ºC  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Ambient  
Case  
-40  
ºC  
Free Air Convection  
RH, Non-condensing  
Humidity  
95  
%
Physical  
Case Size  
Case Material  
MicroPower Direct  
292 Page Street  
Suite D  
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)  
Copper With Nickel Coating (UL94V-0)  
0.60 Oz (17g)  
Weight  
Reliability Specifications  
Parameter  
Stoughton, MA 02072  
USA  
Conditions  
Min.  
910  
Typ.  
Typ.  
Max.  
Units  
kHours  
MTBF  
MIL HDBK 217F, 25ºC, Gnd Benign  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Max.  
25.0  
50.0  
100.0  
260  
Units  
VDC  
ºC  
12 VDC Input -0.7  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
Lead Temperature  
1.5 mm From Case For 10 Sec  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Max  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Number  
Capacitive Efficiency  
Voltage (VDC)  
Current (mA)  
Voltage Current  
Current  
(mA, Min)  
Load  
(%, Typ)  
(VDC)  
(mA, Max)  
Nominal  
Range  
Full-Load No-Load  
(µF Max)  
MA812S-03RW  
MA812S-05RW  
MA812S-12RW  
MA812S-15RW  
MA812D-05RW  
MA812D-12RW  
MA812D-15RW  
MA824S-03RW  
MA824S-05RW  
MA824S-12RW  
MA824S-15RW  
MA824D-05RW  
MA824D-12RW  
MA824D-15RW  
MA848S-03RW  
MA848S-05RW  
MA848S-12RW  
MA848S-15RW  
MA848D-05RW  
MA848D-12RW  
MA848D-15RW  
Notes:  
12  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
48  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
36.0 - 72.0  
36.0 - 72.0  
36.0 - 72.0  
36.0 - 72.0  
36.0 - 72.0  
36.0 - 72.0  
36.0 - 72.0  
687  
762  
784  
803  
813  
794  
794  
344  
381  
392  
397  
407  
402  
392  
172  
191  
198  
198  
203  
196  
196  
20  
20  
20  
20  
20  
20  
20  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
3.3  
5.0  
12.0  
15.0  
5.0  
12.0  
15.0  
3.3  
2,000  
1,500  
665  
535  
800  
335  
265  
2,000  
1,500  
665  
535  
800  
335  
265  
2,000  
1,500  
665  
535  
800  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
3,300  
2,200  
470  
220  
1,000  
220  
80  
82  
85  
83  
82  
84  
84  
80  
82  
85  
84  
82  
83  
85  
80  
82  
84  
84  
82  
85  
85  
2,000  
2,000  
2,000  
2,000  
2,000  
2,000  
2,000  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
500  
500  
500  
500  
500  
500  
500  
100  
3,300  
2,200  
470  
220  
1,000  
220  
5.0  
12.0  
15.0  
5.0  
12.0  
15.0  
3.3  
100  
3,300  
2,200  
470  
220  
1,000  
220  
5.0  
12.0  
15.0  
5.0  
12.0  
15.0  
335  
265  
100  
Derating Curve  
1. Load regulation is specified for a load change of ±% to 1±±%. Load regulation for 3.3V output models  
is 1.5% max for a load change of ±% to 1±±%.  
2. When measuring cross regulation, the load on one output is varied from 25% to 1±±% while the other  
output is held at 1±±%.  
3. When measuring output ripple, it is recommended that an external 1.± µF ceramic capacitor be placed  
from the +VOUT pin to the -VOUT pin for single output units and from each output to common for dual  
output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple.  
4. To help meet conducted emissions requirements, the Pi filter components (C1, & L1) in the diagram  
below should be used. These components should be mounted as close to the module as possible.  
To meet the requirements of EN 61±±±-4-4 and EN 61±±±-4-5, an external filter capacitor (C2 in the  
diagram below) is required.  
5. Operation at no-load will not damage these units. However, they may not meet all specifications.  
6. Dual output units may be connected to provide a 1± VDC, 24 VDC or 3± VDC output.To do this, connect  
the load across the positive (+VOUT) and negative (-VOUT) outputs and float the output common.  
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table  
above for the correct rating.  
Recommended Input Components  
Mechanical Dimensions  
Pin Connections  
Pin  
2
Single  
-VIN  
Dual  
-VIN  
3
-VIN  
-VIN  
9
No Pin  
NC  
+VOUT  
-VOUT  
+VIN  
Common  
-VOUT  
+VOUT  
Common  
+VIN  
11  
14  
16  
22  
23  
+VIN  
+VIN  
NC: No Connection  
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = ±±.±2 (±±.5±)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MA848S12RW

MA800RW SERIES
MPD

MA848S15RW

MA800RW SERIES
MPD

MA850.A.LBIC.001

Worldwide 4G Bands including 3G and 2G
TAOGLAS

MA850ALBIC001

MA850 5in1 Permanent Mount Antenna
TAOGLAS

MA85101BAN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA85101BBN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA85101CAN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA85101CBN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA85101DAN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA85101DBN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA85101FAN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA85101FBN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA