MD300ERWSeries
2:1 Input, 3W SIP,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 3W Output Power
Conditions
Min.
4.5
9.0
Typ.
5.0
12.0
24.0
48.0
4.0
8.0
16.0
33.0
Max.
9.0
18.0
36.0
75.0
4.5
9.0
18.0
36.0
Units
5 VDC Input
12 VDC Input
24 VDC Input 18.0
48 VDC Input 36.0
Input Voltage Range
Input Start Voltage
VDC
• 2:1 Input Voltage Range
• Short Circuit Protected
• 1,500 VDC Isolation
• 29 Standard Models
• Miniature SIP Case
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Low Cost
5 VDC Input
3.5
4.5
12 VDC Input
VDC
24 VDC Input 11.0
48 VDC Input 24.0
Capacitor Filter
Input Filter
Output
Parameter
Output Voltage Accuracy, See Note 1
Output Voltage Balance, See Note 2
Line Regulation
Conditions
Min.
Typ.
1.0
0.5
0.2
0.6
30
35
0.5
2.5
Max.
3.0
1.0
0.5
1.0
45
Units
%
%
%
%
mV P - P
mV P - P
mSec
%
IOUT = 5% to 100%
Dual Outputs, Balanced Loads
VIN = Min to Max
Load Regulation
Ripple (20 MHz)
Noise (20 MHz)
IOUT = 5% to 100%
See Note 3
See Note 3
75
Transient Recovery Time, See Note 4
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
3.0
5.0
0.03
25% Load Step Change
%/°C
Continuous (Autorecovery)
Parameter
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
Typ.
Max.
Units
VDC
M
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
100 kHz/0.1V
120
250
pF
kHz
Standard
See Note 5
See Note 5
Level
Class B
Class B
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
Criteria B; 4 kV Contact
Criteria A; 10V/m
Criteria B; 2 kV
Criteria B; 4 kV
Criteria B; 2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
RS
See Note 6
See Note 6
See Note 7
EFT
Surge
CS
Voltage Dips
Environmental
Parameter
Conditions
Min.
-40
-55
Typ.
+25
Max.
+85
+125
Units
°C
°C
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Free Air Convection
RH, Non-condensing
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Humidity
95
%
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
0.866 x 0.374 x 0.472 Inches (22.00 x 9.50 x 12.00 mm)
Non-Conductive Black Plastic (UL94-V0)
0.17 Oz (4.9g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
Min.
Typ.
Max.
12.0
25.0
50.0
100.0
300
Units
VDC
°C
5 VDC Input -0.7
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Fuse
Rating
Reflected
Capacitive
Load
Model
Number
Efficiency
(%, Typ)
Ripple
Voltage (VDC)
Current (mA)
Full-Load No-Load
Voltage Current
Current
(mA, Min)
Current
(mA Typ)
Slow-Blow
(mA)
(µF, Max)
(VDC)
(mA, Max)
Nominal
5
Range
MD305S-05ERW
MD305S-09ERW
MD305S-12ERW
MD305S-15ERW
MD305D-05ERW
MD305D-12ERW
MD305D-15ERW
MD312S-03ERW
MD312S-05ERW
MD312S-12ERW
MD312S-15ERW
MD312D-05ERW
MD312D-12ERW
MD312D-15ERW
MD324S-03ERW
MD324S-05ERW
MD324S-09ERW
MD324S-12ERW
MD324S-15ERW
MD324S-24ERW
MD324D-05ERW
MD324D-12ERW
MD324D-15ERW
MD348S-05ERW
MD348S-12ERW
MD348S-15ERW
MD348D-05ERW
MD348D-12ERW
MD348D-15ERW
4.5 - 9.0
4.5 - 9.0
685
676
650
676
676
650
650
282
329
305
302
321
317
313
141
155
151
151
151
151
158
151
151
82
40
40
40
40
40
40
40
20
20
20
20
20
20
20
7
7
7
7
7
7
7
7
7
5.0
9.0
12.0
15.0
5.0
12.0
15.0
3.3
500
278
208
167
250
104
83
25.0
14.0
10.0
8.0
13.0
5.0
73
74
77
74
74
77
77
74
76
82
83
78
79
80
74
81
83
83
83
83
79
83
83
76
80
84
79
82
82
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
110.0
110.0
110.0
110.0
110.0
110.0
110.0
110.0
110.0
45.0
45.0
45.0
45.0
45.0
45.0
2,200
1,000
630
470
1,000
470
1,500
1,500
1,500
1,500
1,500
1,500
1,500
750
750
750
750
750
750
750
350
350
350
350
350
350
5
5
5
5
5
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
4.5 - 9.0
5
4.5 - 9.0
4.0
330
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
48
48
48
48
48
48
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
758
600
250
200
300
125
100
758
600
333
250
200
125
300
125
100
600
250
200
300
125
100
38.0
30.0
13.0
10.0
15.0
6.0
2,700
2,200
680
470
1,000
470
5.0
12.0
15.0
5.0
12.0
15.0
3.3
5.0
330
38.0
30.0
17.0
13.0
10.0
6.0
15.0
6.0
5.0
30.0
13.0
10.0
15.0
6.0
2,700
2,200
1,000
680
470
330
1,000
470
330
2,200
680
470
5.0
9.0
12.0
15.0
24.0
5.0
12.0
15.0
5.0
12.0
15.0
5.0
12.0
15.0
350
350
350
200
200
200
200
200
7
7
7
7
7
7
78
75
79
76
1,000
470
330
76
5.0
200
Notes:
Derating Curve
1. At no load, output voltage accuracy is 1.5ꢀ typical and 5.ꢁꢀ max.
2. The load on dual output units should not be unbalanced more than 5 ꢀ. Units
operated with unbalanced loads greater than 5ꢀ may not meet all specifications.
3. When measuring output ripple & noise, it is recommended that an external capacitor
(1ꢁꢁ µF typ.) be placed from the +VOUT to the -VOUT pins for single output units and
from each output to common for dual output models. The maximum output ripple
specified for model MD324S-05ERW is 65 mV.
4. Transient recovery is measured to within a 1ꢀ error band for a load step change
of 25ꢀ.
5. With the addition of the DCFM-0x (or a similar discrete filter), all models will meet EN
55ꢁ22 class B. A suggested input circuit is shown in the connection diagram on page 3.
Contact the factory for more information.
6. To meet the requirements of EN 61ꢁꢁꢁ-4-4 ( 2 kV), external components are needed.
The connection diagram on page 3 shows an external input filter that would typically
achieve this.With the addition of the DCFM-0x, EN 61ꢁꢁꢁ-4-4 ( 4kV) can be achieved.
Contact the factory for more information.
7. To meet the requirements of EN 61ꢁꢁꢁ-4-5 ( 2 kV), external components are needed.
This can be done discretely (as shown in the connection diagram on page 3), or with the
addition of the DCFM-0x. Contact the factory for more information.
8. These units should not be operated with a load under 5ꢀ of full load.Operation at no-load
will not damage the unit, but they may not meet all specifications.
9. It is recommended that a fuse be used on the input of a power supply for protection. See
the Model Selection table above for the correct rating.
Remote ON/OFF Control
The MD300x-ERW may be started or shutdown by the control pin input (pin 3). This input is
current controlled. The unit operates when this input is open. When the input is “high” (current
is flowing into the pin), the converter shuts down. The input current to this pin should be kept
between 5 mA to 1ꢁ mA. Exceeding 2ꢁ mA on this input or connecting it directly to ground
could damage the converter.
The diagram at right gives a suggested input circuit for the control pin. The diode (D1) is an
RB16ꢁM-6ꢁ/1A and CD is is a 47 nF/1ꢁꢁV. The resistor R1 is determined by the formula:
R = [(VC-VD-1.ꢁ)/IC]-3ꢁꢁ
Where: VC = voltage to ground from pin 3
VD = the forward conduction voltage drop of D1
IC = the control pin current (5 - 1ꢁ mA)
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com
Typical Connection
For applications that require meeting EMC standards,the diagram above 6. Recommended values for components are:
7. Thedrawingsbelowshowtypicalboardlayoutsforthe EMC/
EMI circuit shown above (one for single output models and
one for dual output units).
illustrates a typical connection of the MD300xERWseries.The units
do not require external components to operate as specified.Some notes
on this diagram (starting with the input circuit) are:
Component
MOV
LDM1
TVS
C1
5 VIN
---
---
12 VIN
---
---
24 VIN
S14K35
56 µH
48 VIN
S14K60
56 µH
8. In many applications simply adding input/output
capacitors will enhance the input surge protection
and reduce output ripple sufficiently. The value of
the input capacitor can range from 1ꢁ µF to 1ꢁꢁ µF,
depending on the needs of the application. The output
capacitor would typically be 1ꢁꢁ µF.
9. The capacitor CS provides additional output filtering.
If used, a value of 1ꢁ µF to 2ꢁ µF is recommended. This
capacitor is not required for specified operation.
1. An external fuse should be used in all power module applications.
The recommended fuse is shown in the model chart on page 2.
2. To protect against a surge,an external MOV is recommended on the
input. A suggested value is given in the table at right.
3. To protect against voltage spikes, it is recommended that a TVS be
used on the input. A suggested value is given in the table at right.
4. ThecapacitorCS isrequiredtomeetallspecificationsonsingleoutput
units.
5. The output filtering capacitor (C4) is a high frequency,low resistance
electrolytic capacitor. Care must be taken in choosing this capacitor
not to exceed the capacitive load specification for the unit. Voltage
derating of capacitors should be 8ꢁꢀ or above.
SMCJ13A
SMCJ28A
SMCJ48A
SMCJ90A
680 µF/16V 680 µF/25V 330 µF/50V 330 µF/100V
4.7 µF/50V
12 µH
4.7 µF/50V
1nF/2 kV
C2
LDM2
C3
4.7 µF/50V
12 µH
4.7 µF/50V
1nF/2 kV
4.7 µF/50V 4.7 µF/100V
12 µH 12 µH
4.7 µF/50V 4.7 µF/100V
CY
1nF/2 kV
1nF/2 kV
CS
10 µF - 22 µF
C4
100 µF
100 µF
100 µF
100 µF
Typical Board Layout: With External Filter/Surge Components for Single Output Unit
Typical Board Layout: With External Filter/Surge Components for Dual Output Unit
MicroPower Direct
• 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
Input noise and surge suppression modules are available for The recommended input capacitor (C1) is a 33ꢁ µF/5ꢁV
www.micropowerdirect.com
a number of MPD DC/DC power supplies. An MD300xERW
connection with the DCFM-02 (noise suppression) module
connected to the input is shown in the diagrams below.
for 5, 12, and 24 VDC input models and 33ꢁ µF/1ꢁꢁV for
48 VDC input units. The output capacitors (C2 & C3) are
1ꢁꢁ µF. For pricing or full technical information on these modules (DCFM-01, DCFM-02 and DCFM-03) please contact the factory.
Typical Connection: With DCFM-02 Surge Suppression and Filter Modules, Single Output
Typical Connection: With DCFM-02 Surge Suppression and Filter Modules, Dual Output
Mechanical Dimensions
Pin Connections
Pin
1
Single Output
-VIN
2
+VIN
3
5
6
Remote On/Off
No Connection
+VOUT
7
-VOUT
8
CS
Pin
1
Dual Output
-VIN
2
+VIN
3
5
6
Remote On/Off
No Connection
+VOUT
7
8
Common
-VOUT
Notes:
All dimensions are typical in inches (mm)
Pin Section Tolerance x.xxx = ꢁ.ꢁꢁ4 ( ꢁ.1ꢁꢁ)
General Tolerance x.xx = ꢁ.ꢁ1 ( ꢁ.25)
Pin 1 is marked by a “dot” or indentation on the top of the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com