MD612S-03RWI [MPD]
2:1 Input, SIP, High Isolation, 6W DC/DC Converters;型号: | MD612S-03RWI |
厂家: | MICROPOWER DIRECT, LLC |
描述: | 2:1 Input, SIP, High Isolation, 6W DC/DC Converters |
文件: | 总4页 (文件大小:840K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MD600xRWISeries
2:1 Input, SIP,
High Isolation, 6W
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 6W Output Power
Conditions
Min.
4.5
9.0
Typ.
5.0
12.0
24.0
48.0
30
Max.
9.0
18.0
36.0
75.0
Units
5 VDC Input
12 VDC Input
24 VDC Input 18.0
48 VDC Input 36.0
• Miniature SIP Case
• 2:1 Input Voltage Range
• 3,000 VDC Isolation
• 36 Standard Models
• Short Circuit Protected
• -40°C to +65°C Operation
• Single & Dual Outputs
• Industry Standard Pin-Out
Input Voltage Range
VDC
Input Reflected Ripple Current
Start Up Time
Input Filter
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
mA P - P
mS
See Note 1
30
Capacitor Filter
Conditions
Min.
Typ.
1.0
Max.
Units
%
%
%
%
mV P - P
mSec
%
VIN = Min to Max
IOUT = 0% to 100%
See Note 2
0.2
1.0
5.0
75
Cross Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
See Note 3
0.5
See Note 4
3.0
0.02
%/°C
Continuous (Autorecovery)
Parameter
Isolation Voltage
Conditions
Min.
60 Seconds 3,000
1.0
Typ.
Max.
Units
VDC
G
pF
kHz
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
50
100
Standard
Level
Radiated Emissions
Conducted Emissions
EN 55022
EN 55022
Class A
Class A
See Note 4 Pg 3
Criteria A; 8 kV Air
Criteria A; 6 kV Contact
Criteria A; 10V/m
ESD
EN 61000-4-2
RS
EFT
Surge
CS
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
See Note 6 Pg 3
See Note 6 Pg 3
Criteria A; 2 kV
Criteria A; 1 kV
Criteria A; 10 Vrms
Criteria A; 1A/m
PFMF
Environmental
Parameter
Conditions
Min.
-40
Typ.
+25
Max.
+65
+105
+125
Units
°C
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-55
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
See Mechanical Drawing (Page 4)
Non-Conductive Black Plastic (UL94-V0)
0.166 Oz (4.8g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
770
Typ.
Typ.
Max.
Units
kHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Absolute Maximum Ratings
Parameter
Conditions
5 VDC Input
Min.
Max.
15.0
25.0
50.0
100.0
260
Units
VDC
°C
12 VDC Input
24 VDC Input
48 VDC Input
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Fuse
Rating
Capacitive
Load
Model
Number
Efficiency
(%, Typ)
Voltage (VDC)
Current (mA)
Full-Load No-Load
Voltage Current
Current
(mA, Min)
Slow-Blow
(mA)
(µF, Max)
(VDC)
(mA, Max)
Nominal
5
Range
MD605S-03RWI
MD605S-05RWI
MD605S-09RWi
MD605S-12RWI
MD605S-15RWI
MD605S-24RWI
MD605D-05RWI
MD605D-12RWI
MD605D-15RWI
MD612S-03RWI
MD612S-05RWI
MD612S-09RWI
MD612S-12RWI
MD612S-15RWI
MD612S-24RWI
MD612D-05RWI
MD612D-12RWI
MD612D-15RWI
MD624S-03RWI
MD624S-05RWI
MD624S-09RWI
MD624S-12RWI
MD624S-15RWI
MD624S-24RWI
MD624D-05RWI
MD624D-12RWI
MD624D-15RWI
MD648S-03RWI
MD648S-05RWI
MD648S-09RWI
MD648S-12RWI
MD648S-15RWI
MD648S-24RWI
MD648D-05RWI
MD648D-12RWI
MD648D-15RWI
4.5 - 9.0
4.5 - 9.0
1,144
1,519
1,445
1,428
1,428
1,428
1,481
1,428
1,428
470
105
105
105
105
105
105
105
105
105
55
3.3
5.0
1,300
1,200
666
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
75
79
83
84
84
84
81
84
84
76
83
84
85
85
86
82
84
86
78
83
85
85
87
87
82
84
84
76
80
85
84
86
84
82
85
85
6,600
3,300
2,000
1,600
1,400
680
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
1,250
1,250
1,250
1,250
1,250
1,250
1,250
1,250
1,250
750
5
5
4.5 - 9.0
9.0
5
4.5 - 9.0
12.0
15.0
24.0
5.0
500
5
4.5 - 9.0
400
5
4.5 - 9.0
250
5
4.5 - 9.0
600
2,000
900
5
4.5 - 9.0
12.0
15.0
3.3
250
5
4.5 - 9.0
200
660
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
48
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
1,300
1,200
666
6,600
3,300
2,000
1,600
1,400
680
602
55
5.0
595
55
9.0
588
55
12.0
15.0
24.0
5.0
500
588
55
400
581
55
250
609
55
600
2,000
900
595
55
12.0
15.0
3.3
250
581
55
200
660
229
30
1,300
1,200
666
6,600
3,300
2,000
1,600
1,400
680
301
30
5.0
750
294
30
9.0
750
294
30
12.0
15.0
24.0
5.0
500
750
287
30
400
750
287
30
250
750
304
30
600
2,000
900
750
297
30
12.0
15.0
3.3
250
750
297
30
200
660
750
117
15
1,300
1,200
666
6,600
3,300
2,000
1,600
1,400
680
300
156
15
5.0
300
147
15
9.0
300
149
15
12.0
15.0
24.0
5.0
500
300
145
15
400
300
148
15
250
300
152
15
600
2,000
900
300
147
15
12.0
15.0
250
300
147
15
200
660
300
Derating Curve
For Remote Control option, add suffix “R” to
model number (i.e. MD624S-05RWI-R)
Notes:
1. Start up time is specified at nominal input and with a constant resistive
load.
2. Cross regulation is measured by monitoring one output set at 100% load
while varying the second output from 25% to 100% load.
3. When measuring output ripple & noise, it is recommended that an external
ceramic capacitor (0.1 µF typ.) be placed from the +VOUT to the -VOUT pins for
single output units and from each output to common for dual output models.
4. Transient recovery is measured to within a 1% error band for a load step
change of 25%.
5. Free air convection is typically 30 - 65 LFM.THe units should not be operated
in still air (0 LFM).
6. Exceeding the absollute ratings could damage the unit.
7. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
Typical Connection
www.micropowerdirect.com
For applications that require meeting EMC standards,the diagram above 5. Recommended values for components are:
7. The output filtering capacitor (C6) is a high frequency, low
resistance electrolytic capacitor. Care must be taken in
choosing this capacitor not to exceed the capacitive load
specification for the unit. Voltage derating of capacitors
should be 80% or above
8. The drawings below show typical board layouts for the EMI
circuit shown above (one for single output models and one
for dual output units).
9. In many applications simply adding input/output
capacitors will enhance the input surge protection
and reduce output ripple sufficiently. The value of
the input capacitor can range from 220 µF to 330 µF,
depending on the needs of the application. The output
capacitor would typically be 10 µF.
illustrates a typical connection of the MD600xRWI series.The units
do not require external components to operate as specified.Some notes
on this diagram (starting with the input circuit) are:
Component
5 VIN
12 VIN
24 VIN
48 VIN
C1
C2
LDM1
C3
C4
C5
220 µF/25V
22 µF/25V
10 µH
10 µF/50V
10 µH
10 µF/50V
10 µF/50V 2.2 µF/100V
10 µH 15 µH
10 µF/50V 2.2 µF/100V
1. An external fuse should be used in all power module applications.
The recommended fuse is shown in the model chart on page 2.
2. To protect against a surge,an external MOV is recommended on the
input. For a suggested value, contact the factory.
3. To protect against voltage spikes, it is recommended that a TVS be
used on the input. For a suggested value, contact the factory.
4. The filtering components shown are needed to meet the conducted
emissionsrequirementsforEN55022ClassA.Allcomponentsshould
be mounted as close to the converter as possible.
22 µF/25V
220 pF/3 kV 220 pF/3 kV 220 pF/3 kV 220 pF/3 kV
220 pF/3 kV 220 pF/3 kV 220 pF/3 kV 220 pF/3 kV
10 µF - 22 µF
C6
6. To meet the requirements of EN 61000-4-4 and EN 61000-4-5,an external input capacitor
is required for all models.The suggested value is 330 µF/100V. Contact the factory
for more information
Typical Board Layout: With External Filter Components for Single Output Unit
Typical Board Layout: With External Filter Components for Dual Output Unit
MicroPower Direct
• 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
Remote ON/OFF Control
www.micropowerdirect.com
The MD600x-xxRWI is available with an optional remote control input. This input (pin 3) is
current controlled. The unit operates when this input is open. When the input is “high” (cur-
rent is flowing into the pin), the converter shuts down. The input current to this pin should be
kept between 2 mA to 4 mA.
The diagram at right shows a simple connection for the control pin.
To order units with the control input, add a “-R” to the model number (i.e. MD605D-12RWI-R).
Remote On/Off
Parameter
Supply On
Supply Off
Standby Input Current
Min.
Typ.
Open or High Impedance
mA
mA
Max.
Units
2
4
2.5
Mechanical Dimensions
Pin Connections
Standard Model
Remote Control Model
Pin
1
Single Output
-VIN
Pin
1
Single Output
-VIN
2
+VIN
2
+VIN
3
5
6
No Pin
No Pin
+VOUT
3
5
6
Remote On/Off
No Connection
+VOUT
7
-VOUT
7
-VOUT
8
No Connection
8
No Connection
Pin
1
Dual Output
-VIN
Pin
1
Dual Output
-VIN
2
3
5
6
+VIN
2
3
5
6
+VIN
Notes:
No Connection
No Connection
+VOUT
Remote On/Off
No Connection
+VOUT
•
•
•
All dimensions are typical in inches (mm)
Tolerance x.xx = 0.02 ( 0.5)
Pin 1 is marked by a “dot” or indentation on the top of the unit
7
8
Common
-VOUT
7
8
Common
-VOUT
For Remote Control option, add suffix “R” to
model number (i.e. MD624S-05RWI-R)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com