MD924S-05RU [MPD]

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers;
MD924S-05RU
型号: MD924S-05RU
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers

文件: 总4页 (文件大小:895K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MD900xRUSeries  
4:1 Input, 9W SIP,  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Key Features:  
Conditions  
24 VDC Input  
Min.  
Typ.  
24.0  
48.0  
7.0  
14.0  
50.0  
Max.  
36.0  
75.0  
8.9  
Units  
9.0  
9W Output Power  
Input Voltage Range  
VDC  
48 VDC Input 18.0  
24 VDC Input  
48 VDC Input  
See Note 2  
Miniature SIP Case  
4:1 Input Voltage Range  
Short Circuit Protected  
1,600 VDC Isolation  
Efficiency To 89%  
Under Voltage Lockout  
VDC  
16.0  
Start Up Time  
Input Reflected Ripple Current  
Input Filter  
mS  
mA P - P  
30.0  
Capacitor Filter  
Output  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
1.0  
0.2  
1.0  
0.5  
1.0  
5.0  
75  
Units  
%
%
Output Voltage Accuracy  
Line Regulation  
Over Voltage Protection  
Over Current Protection  
-40°C to +85°C Operation  
Industry Standard Pin-Out  
Low Cost  
VIN = Min to Max  
3.3 VOUT Models  
Other Single Output Models  
Dual Output Models  
See Note 4  
Load Regulation, See Note 3  
%
Cross Regulation  
%
mV P - P  
µSec  
%
%/°C  
%
Ripple & Noise (20 MHz)  
Transient Recovery Time, See Note 6  
Transient Response Deviation  
Temperature Coefficient  
Over Voltage Protection  
Over Current Protection  
Output Short Circuit  
General  
See Note 5  
250  
25% Load Step Change  
3.0  
0.02  
130  
180  
%
Continuous (Autorecovery)  
Parameter  
Conditions Min. Typ.  
Max.  
Units  
Input to Output 1,600  
Case To Input or Output 1,000  
1,000  
Isolation Voltage, See Note 7  
VDC  
Isolation Resistance  
Isolation Capacitance  
M  
pF  
50  
24 VIN Models  
48 VIN Models  
400  
500  
Switching Frequency  
kHz  
EMI Characteristics  
Parameter  
Radiated Emissions, See Note 8  
Conducted Emissions, See Note 8  
Standard  
Criteria  
Level  
Class A  
Class A  
EN 55032  
EN 55032  
ESD  
RS  
EN 61000-4-2  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-8  
B
A
A
A
A
A
6 kV Contact, 8 kV Air  
20V/rms  
2 kV  
2 kV  
10 Vrms  
100 A/m  
EFT, See Note 9  
Surge, See Note 10  
CS  
PFMF  
Environmental  
Parameter  
Conditions  
Min.  
Typ.  
+25  
Max.  
+85  
+100  
+125  
Units  
°C  
Ambient  
Case  
-40  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
-55  
°C  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Free Air Convection  
Humidity  
Physical  
Case Size  
Case Material  
Weight  
RH, Non-condensing  
95  
%
See Mechanical Diagram (Page 4)  
Black, Anodized Copper (UL94-V0)  
0.25 Oz (7.3g)  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Reliability Specifications  
Parameter  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Min.  
Typ.  
Max.  
Units  
MHours  
MTBF  
1.0  
Absolute Maximum Ratings  
Parameter  
Conditions  
24 VDC Input  
48 VDC Input  
1.5 mm From Case for 10 Sec  
Min.  
Typ.  
Max.  
50.0  
100.0  
260  
Units  
VDC  
°C  
Input Voltage Surge (1 Sec)  
Lead Temperature  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Fuse  
Capacitive  
Load  
Model  
Number  
Efficiency  
(%, Typ)  
Rating  
Voltage (VDC)  
Current (mA)  
Full-Load No-Load  
Voltage Current  
Current  
(mA, Min)  
Slow-Blow  
(mA)  
F, Max)  
(VDC)  
(mA, Max)  
Nominal  
24  
Range  
MD924S-03RU  
MD924S-05RU  
MD924S-09RU  
MD924S-12RU  
MD924S-15RU  
MD924S-24RU  
MD924D-05RU  
MD924D-12RU  
MD924D-15RU  
MD948S-03RU  
MD948S-05RU  
MD948S-09RU  
MD948S-12RU  
MD948S-15RU  
MD948S-24RU  
MD948D-05RU  
MD948D-12RU  
MD948D-15RU  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
335  
392  
426  
426  
421  
421  
392  
426  
431  
168  
196  
216  
213  
211  
211  
196  
216  
216  
9
9
9
9
9
9
9
9
9
5
5
5
5
5
5
5
5
5
3.3  
5.0  
2,000  
1,600  
1,000  
750  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
82  
85  
88  
88  
89  
89  
85  
88  
87  
82  
85  
87  
88  
89  
89  
85  
87  
87  
2,600  
1,300  
800  
2,000  
2,000  
2,500  
2,500  
2,500  
2,500  
2,000  
2,500  
2,500  
1,000  
1,000  
1,500  
1,500  
1,500  
1,500  
1,000  
1,500  
1,500  
24  
24  
9.0  
24  
12.0  
15.0  
24.0  
5.0  
560  
24  
600  
560  
24  
375  
200  
24  
800  
800  
24  
12.0  
15.0  
3.3  
375  
390  
24  
300  
200  
48  
2,000  
1,600  
1,000  
750  
2,600  
1,300  
800  
48  
5.0  
48  
9.0  
48  
12.0  
15.0  
24.0  
5.0  
560  
48  
600  
560  
48  
375  
200  
48  
800  
800  
48  
12.0  
15.0  
375  
390  
48  
300  
200  
2:1 Input Models Are Also Available  
See The MD900xRW  
Derating Curve  
Notes:  
1. The specified maximum capacitive load is for each output.  
2. Start up time is specified at the nominal Voltage input and with a constant  
resistive load.  
3. Load regulation is specified for a load change of 0% to 100%.  
4. Cross regulation is specified with one output at full load while the other  
output is varied from 25% to 100% load.  
5. Output ripple is measured with a 1 μF ceramic capacitor and a 10 μF  
electrolytic capacitor connected in parallel.  
6. Transient recovery is measured to within a 1% error band for a load  
step change of 25%. Single 3.3 & 5 VDC output models have a response  
deviation of 5.0% Max.  
7. Isolation voltage ratings are for 60 seconds.  
8. With the addition of external filter and protection components, all models will  
meet the requirements of EN 55032 classA.Suggested input circuits are shown  
in the connection diagrams on page 3.Contact the factory for more information.  
9. To meet the requirements of EN 61000-4-4 ( 2 kV), external components  
are needed.The connection diagrams on page 3 shows external components  
that would typically achieve this. Contact the factory for more information.  
10. To meet the requirements of EN 61000-4-5 ( 2 kV), external components are  
needed. This can be done as shown in the connection diagrams on page 3.  
Contact the factory for more information.  
11. Operation at no-load will not damage the unit, but they may not meet all  
specifications.  
12. It is recommended that a fuse be used on the input of a power supply for  
protection. See the Model Selection table above for the correct rating.  
Remote ON/OFF Control  
The MD900x-RU may be started or shutdown by the control pin  
input (pin 3). This input is current controlled. The unit operates  
when this input is left open. When the input is “high” (current is  
flowing into the pin), the converter shuts down. The input current  
to this pin must be kept between 2 mA to 4 mA.  
The diagram at right shows a simple input circuit for the control  
pin. Closing the switch causes 2 - 4 mA to flow through the 1 k  
resister, shutting the unit off.  
MicroPower Direct  
292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
For applications that require meeting EMC standards, the diagrams below illustrate typi-  
cal connections of the MD900xRU series. Some notes on this diagram (starting with the  
input circuit) are:  
www.micropowerdirect.com  
3. The output filtering components C9 & C11 are high frequency, low ESR electrolytic  
capacitors. Capacitors C10 & C12 are ceramic. Care must be taken in choosing  
these capacitors not to exceed the capacitive load specification for the unit. Voltage  
derating of capacitors should be 80% or above.  
1. An external fuse should be used in all power module applications. The recommended  
fuse is shown in the model chart on page 2.  
2. To protect against voltage spikes, it is recommended that a TVS be used on the input.  
A suggested value is given in the tables below.  
Typical Connection: 24 VIN, Single Output Models  
Recommended component values are:  
Component  
Value  
330 μF/100V  
3KW, 70V  
1210 106M/35V  
20 μH  
C1  
TVS  
C2, C3, C4  
L1  
L2  
C5, C6, C7, C8  
C9  
20 μH  
1808 221K/3kV  
10 μF  
C10  
1 μF  
Typical Connection: 24 VIN, Dual Output Models  
Component  
C1  
Value  
330 μF/100V  
3KW, 70V  
1210 106M/35V  
20 μH  
TVS  
C2, C3, C4  
L1  
L2  
20 μH  
C5, C6, C7, C8  
C9, C11  
C10, C12  
1808 221K/3kV  
10 μF  
1 μF  
Typical Connection: 48 VIN, Single Output Models  
Component  
Value  
330 μF/100V  
3KW, 70V  
1210 106M / 35V  
132.8 μH  
10 μH  
C1  
TVS  
C2, C3, C4  
L1  
L2  
C5, C6, C7, C8  
C9  
1808 221K/3kV  
10 μF  
C10  
1 μF  
Typical Connection: 48 VIN, Dual Output Models  
Component  
C1  
Value  
330 μF/100V  
3KW, 70V  
1210 106M/35V  
132.8 μH  
10 μH  
TVS  
C2, C3, C4  
L1  
L2  
C5, C6, C7, C8  
C9, C11  
C10, C12  
1808 221K/3kV  
10 μF  
1 μF  
MicroPower Direct  
292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
www.micropowerdirect.com  
Mechanical Dimensions  
It is not required that the user connect the case ground  
tabs (9 & 10 on the mechanical diagram) to the PCB.  
However, connecting one or both tabs to a ground  
plane on the PCB will help:  
Pin Connections  
Improve the unit’s resistance to vibration  
Improve the units ability to dissipate heat  
Improve the unit’s resistance to ESD  
Pin  
1
Single Output  
-VIN  
Pin  
1
2
3
6
Dual Output  
-VIN  
+VIN  
Remote On/Off  
+VOUT  
2
+VIN  
Call the factory for more information  
3
6
Remote On/Off  
+VOUT  
7
8
9
10  
-VOUT  
No Connection  
Case  
7
8
9
10  
Common  
-VOUT  
Case  
Notes:  
All dimensions are typical in inches (mm)  
Pin Section Tolerance x.xxx = 0.004 ( 0.100)  
General Tolerance x.xx = 0.01 ( 0.25)  
Pin 1 is marked by a “dot” or indentation on the top of the unit  
Case  
Case  
Also Available:  
MD900xRW  
Key Features:  
9W Output Power  
For those applications that require high power den-  
sity, but not a very wide input range, MPD offers the  
MD900xRW series. These units also feature high power  
density, a very high performance envelope and a wide  
range of standard models. However, since thay are 2:1  
input designs, they are offered at a lower cost.  
Miniature SIP Case  
2:1 Input Voltage Range  
27 Single & Dual Output Models  
1,600 VDC Isolation  
Check them out now, or call the factory for free samples.  
Miniature SIP Case  
-40°C to +85°C Operation  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MD924S-09RU

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers
MPD

MD924S-12RU

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers
MPD

MD924S-15RU

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers
MPD

MD924S-24RU

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers
MPD

MD942

Ultra High Sensitivity Gateable Channel Photomultiplier DC-Modules
PERKINELMER

MD943

Ultra High Sensitivity Gateable Channel Photomultiplier DC-Modules
PERKINELMER

MD948D-05RU

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers
MPD

MD948D-12RU

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers
MPD

MD948D-15RU

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers
MPD

MD948S-03RU

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers
MPD

MD948S-05RU

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers
MPD

MD948S-09RU

4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers
MPD